Comparison among low-cost portable systems for thoracic impedance plethysmography

Impedance plethysmography is a technique which allows the monitoring of respiratory activity through the measurement of variations in the trans-thoracic impedance. Provided the measurement system has enough sensitivity, the same technique can also detect heartbeats, thus adding cardiac activity monitoring capabilities. In this paper, a comparison is performed between 2-electrode and 4-electrode systems, considering both volt-amperometric and AC-bridge solutions. Attention is focused on low-cost, easily portable, and reconfigurable measurement set-ups, whose performances are analyzed in terms of sensitivity and accuracy. To this end, LabVIEW virtual instruments based on a data acquisition card are employed. An experimental metrological assessment of the systems shows that their basic accuracy is definitely adequate for patient monitoring. However, based on a theoretical study on measurement resolution, only the volt-amperometric solution in 4-electrode configuration achieves enough sensitivity to correctly detect the cardiac activity. The above conclusion is verified by acquisitions made on several volunteers.

[1]  L. E. Baker,et al.  A comparison of linear and non-linear characterizations of impedance spirometry data , 2006, Medical and biological engineering.

[2]  Hsiao-Lung Chan,et al.  Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition , 2015, Sensors.

[3]  Stefano Pisa,et al.  A virtual instrument for trans-thoracic impedance investigations , 2008 .

[4]  Shabana Urooj,et al.  Measurement of Thoracic Impedance and Approximations: A Diagnosis Technique for Clinical Utilisation , 2013 .

[5]  J. Nyboer,et al.  Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study , 1950, Circulation.

[6]  J. Rosell,et al.  Reduction of motion artifacts using a two-frequency impedance plethysmograph and adaptive filtering , 1995, IEEE Transactions on Biomedical Engineering.

[7]  R. V. Hill,et al.  Electrical impedance plethysmography: a critical analysis. , 1967, Journal of applied physiology.

[8]  Stefano Pisa,et al.  A DAQ-based virtual instrument for trans-thoracic impedance investigations , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[9]  Stefano Pisa,et al.  Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[10]  Willis J. Tompkins,et al.  Electrode Motion Artifacts in Electrical Impedance Pneumography , 1985, IEEE Transactions on Biomedical Engineering.

[11]  Wils L. Cooley,et al.  A new design for an impedance pneumograph , 1968 .

[12]  Sushma N Bhat,et al.  Seventy-five Years of Use of Impedance Plethysmography in Physiological Data Acquisition and Medical Diagnostics. , 2016 .