Remote voltage synchronization for wireless Partial Discharge diagnostics

The main objective of this paper is the assessment of the exact phase angle displacement of each Partial Discharge, PD, pulse with respect to the voltage reference waveform. Such problem also referred to as `synchronization' is relevant when the cable is not accessible and the PD measure is carried out in wireless mode. It is well known, that the angle phase shift, due to the propagation phenomenon on the transmission line, can be calculated knowing the line type and length and typical operating conditions of the transmission line. The setup comprises a customized electronic device, the “Phase check”, a server to collect remote measurements and a Look up table to provide corrections to the measured phase shift values. To evaluate the voltage phase shift introduced by a transmission line, different simulations have been carried out in PSCAD. Then, to prove the correctness of simulated results and verify the “Phase check” precision, experimental measurements have been carries out on three transmission lines in Sicily, Italy. The experimental measurements prove that the proposed setup is effective and quite useful to provide precise assessment of voltage phase shift for PD wireless diagnosis.

[1]  Masayoshi Tanaka,et al.  Electromagnetic waves from partial discharges and their detection using patch antenna , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  M. V. Rojas-Moreno,et al.  Antenna selection and frequency response study for UHF detection of partial discharges , 2012, 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[3]  S. Tenbohlen,et al.  On-site experiences with multi-terminal IEC PD measurements, UHF PD measurements and acoustic PD localisation , 2010, 2010 IEEE International Symposium on Electrical Insulation.

[4]  M. Lehtonen,et al.  Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  Eva Rajo-Iglesias,et al.  Antenna Parametrization for the Detection of Partial Discharges , 2013, IEEE Transactions on Instrumentation and Measurement.

[6]  P.A.A.F. Wouters,et al.  Synchronization of on-line PD detection and localization setups using pulse injection , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[7]  M. Lehtonen,et al.  Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks , 2011 .

[8]  S. Tenbohlen,et al.  Partial discharge measurement in the ultra high frequency (UHF) range , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  C. Koley,et al.  Microstrip patch antenna based UHF sensor for detection of Partial Discharge in High Voltage electrical equipments , 2014, 2014 Annual IEEE India Conference (INDICON).

[10]  Roberto Candela,et al.  A novel partial discharge detection system based on wireless technology , 2013, AEIT Annual Conference 2013.

[11]  Rosario Miceli,et al.  Performance of the shape of Partial Discharge signal wireless probes , 2013, 4th International Conference on Power Engineering, Energy and Electrical Drives.