Motor-unit synchronization increases EMG amplitude and decreases force steadiness of simulated contractions.

The purpose of the study was to determine the effect of motor-unit synchronization on the surface electromyogram (EMG) and isometric force using a computer model of muscle contraction. The EMG and force were simulated by generating muscle fiber action potentials, defining motor-unit mechanical characteristics and territories, estimating motor-unit action potentials, specifying motor-unit discharge times, and imposing various levels of motor-unit synchronization. The output (EMG and force) was simulated at 11 levels of excitation, ranging from 5 to 100% of maximum. To synchronize motor-unit activity, selected motor-unit discharge times were adjusted; however, the number of motor units recruited and the average discharge rate of each unit was constant across synchronization conditions for a given level of excitation. Two levels of synchronization were imposed on the discharge times: a moderate and a high level, which approximated the experimentally observed range of motor-unit synchronization. The moderate level of synchrony caused the average EMG to increase by approximately 65%, whereas the high level caused a 130% increase in the EMG with respect to the no-synchrony condition. Neither synchrony condition influenced the magnitude of the average force. However, motor-unit synchronization did increase the amplitude of the fluctuations in the simulated force, especially at intermediate levels of excitation. In conclusion, motor-unit synchronization increased the amplitude of the average rectified EMG and decreased the steadiness of the force exerted by the muscle in simulated contractions.

[1]  B. Feinstein,et al.  Morphologic studies of motor units in normal human muscles. , 1955, Acta anatomica.

[2]  F. Plum Handbook of Physiology. , 1960 .

[3]  D. Kernell High-Frequency Repetitive Firing of Cat Lumbosacral Motoneurones Stimulated by Long-Lasting Injected Currents , 1965 .

[4]  P. Rack,et al.  The effects of length and stimulus rate on tension in the isometric cat soleus muscle , 1969, The Journal of physiology.

[5]  E Henneman,et al.  Terminals of single Ia fibers: location, density, and distribution within a pool of 300 homonymous motoneurons. , 1971, Journal of neurophysiology.

[6]  W. Crill,et al.  Penicillin-induced segmental myoclonus. II. Membrane properties of cat spinal motoneurons. , 1972, Archives of neurology.

[7]  R. Stein,et al.  Changes in firing rate of human motor units during linearly changing voluntary contractions , 1973, The Journal of physiology.

[8]  R B Stein,et al.  The orderly recruitment of human motor units during voluntary isometric contractions , 1973, The Journal of physiology.

[9]  R. Stein,et al.  The contractile properties of human motor units during voluntary isometric contractions , 1973, The Journal of physiology.

[10]  J Tanji,et al.  Firing rate of individual motor units in voluntary contraction of abductor digiti minimi muscle in man. , 1973, Experimental neurology.

[11]  R. Stein,et al.  Synchronization of human motor units: possible roles of exercise and supraspinal reflexes. , 1975, Electroencephalography and clinical neurophysiology.

[12]  R. Stein,et al.  The relation between the surface electromyogram and muscular force. , 1975, The Journal of physiology.

[13]  T. Sears,et al.  Short‐term synchronization of intercostal motoneurone activity. , 1976, The Journal of physiology.

[14]  A. Monster,et al.  Isometric force production by motor units of extensor digitorum communis muscle in man. , 1977, Journal of neurophysiology.

[15]  T. P. Usherwood,et al.  The mechanical properties of human motor units with special reference to their fatiguability and recruitment threshold , 1977, Brain Research.

[16]  T. Sears,et al.  The synaptic connexions to intercostal motoneurones as revealed by the average common excitation potential. , 1978, The Journal of physiology.

[17]  Steen Andreassen,et al.  Recording from a Single Motor Unit During Strong Effort , 1978, IEEE Transactions on Biomedical Engineering.

[18]  P H Ellaway,et al.  Cumulative sum technique and its application to the analysis of peristimulus time histograms. , 1978, Electroencephalography and clinical neurophysiology.

[19]  P. Matthews,et al.  Comparison of electromyogram spectra with force spectra during human elbow tremor. , 1980, The Journal of physiology.

[20]  E. Fetz,et al.  Postspike facilitation of forelimb muscle activity by primate corticomotoneuronal cells. , 1980, Journal of neurophysiology.

[21]  R. Burke Motor Units: Anatomy, Physiology, and Functional Organization , 1981 .

[22]  S. Andreassen,et al.  Relationship of intracellular and extracellular action potentials of skeletal muscle fibers. , 1981, Critical reviews in bioengineering.

[23]  C. D. De Luca,et al.  Behaviour of human motor units in different muscles during linearly varying contractions , 1982, The Journal of physiology.

[24]  B. Bigland-ritchie,et al.  Linear and non-linear surface EMG/force relationships in human muscles. An anatomical/functional argument for the existence of both. , 1983, American journal of physical medicine.

[25]  C. D. De Luca,et al.  Myoelectric signal versus force relationship in different human muscles. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[26]  R. A. Davidoff Handbook of the spinal cord , 1983 .

[27]  R. Dengler,et al.  Synchronous discharges in pairs of steadily firing motor units tend to form clusters , 1984, Neuroscience Letters.

[28]  B. Gustafsson,et al.  An investigation of threshold properties among cat spinal alpha‐motoneurones. , 1984, The Journal of physiology.

[29]  M. Binder,et al.  Distribution of oligosynaptic group I input to the cat medial gastrocnemius motoneuron pool. , 1985, Journal of neurophysiology.

[30]  R. Lemon,et al.  Selective facilitation of different hand muscles by single corticospinal neurones in the conscious monkey. , 1986, The Journal of physiology.

[31]  H Hefter,et al.  The muscle activity spectrum: spectral analysis of muscle force as an estimator of overall motor unit activity. , 1986, Electroencephalography and clinical neurophysiology.

[32]  S. Andreassen,et al.  Muscle fibre conduction velocity in motor units of the human anterior tibial muscle: a new size principle parameter. , 1987, The Journal of physiology.

[33]  H. Clamann,et al.  Nonlinear force addition of newly recruited motor units in the cat hindlimb , 1988, Muscle & nerve.

[34]  D. Stuart,et al.  Fatigability of rat hindlimb muscle: associations between electromyogram and force during a fatigue test. , 1989, Journal of Physiology.

[35]  J. Stephens,et al.  Synchronization of motor unit activity during voluntary contraction in man. , 1990, The Journal of physiology.

[36]  Marc D. Binder,et al.  The Segmental motor system , 1990 .

[37]  M D Binder,et al.  Computer simulation of the steady-state input-output function of the cat medial gastrocnemius motoneuron pool. , 1991, Journal of neurophysiology.

[38]  M. Binder,et al.  Summation of motor unit tensions in the tibialis posterior muscle of the cat under isometric and nonisometric conditions. , 1991, Journal of neurophysiology.

[39]  M. Taussig The Nervous System , 1991 .

[40]  J. Stephens,et al.  Effect of task on the degree of synchronization of intrinsic hand muscle motor units in man. , 1991, Journal of neurophysiology.

[41]  A J Fuglevand,et al.  Estimating the strength of common input to human motoneurons from the cross‐correlogram. , 1992, The Journal of physiology.

[42]  D. Halliday,et al.  The frequency content of common synaptic inputs to motoneurones studied during voluntary isometric contraction in man. , 1993, The Journal of physiology.

[43]  A J Fuglevand,et al.  Impairment of neuromuscular propagation during human fatiguing contractions at submaximal forces. , 1993, The Journal of physiology.

[44]  D. Winter,et al.  Models of recruitment and rate coding organization in motor-unit pools. , 1993, Journal of neurophysiology.

[45]  R. Enoka,et al.  Reduced control of motor output in a human hand muscle of elderly subjects during submaximal contractions. , 1993, Journal of neurophysiology.

[46]  R M Enoka,et al.  Training-related enhancement in the control of motor output in elderly humans. , 1994, Journal of applied physiology.

[47]  A Schmied,et al.  Human spinal lateralization assessed from motoneurone synchronization: dependence on handedness and motor unit type. , 1994, The Journal of physiology.

[48]  M. Hulliger,et al.  EMG-force relationship of the cat soleus muscle studied with distributed and non-periodic stimulation of ventral root filaments. , 1994, The Journal of experimental biology.

[49]  Michael A. Nordstrom,et al.  Relationship between motor unit short-term synchronization and common drive in human first dorsal interosseous muscle , 1997, Brain Research.

[50]  D. Stegeman,et al.  Motor unit potential contribution to surface electromyography. , 1997, Acta physiologica Scandinavica.

[51]  C. Marsden,et al.  Frequency peaks of tremor, muscle vibration and electromyographic activity at 10 Hz, 20 Hz and 40 Hz during human finger muscle contraction may reflect rhythmicities of central neural firing , 1997, Experimental Brain Research.

[52]  MOTOR UNIT DISCHARGE RATE IS MORE VARIABLE IN OLDER ADULTS PERFORMING SLOW FINGER MOVEMENTS 132 , 1997 .

[53]  Erhard J. Huesler,et al.  Task dependence of muscle synchronization in human hand muscles , 1998, Neuroreport.

[54]  J. Duchateau,et al.  Changes in single motor unit behaviour contribute to the increase in contraction speed after dynamic training in humans , 1998, The Journal of physiology.

[55]  Andrew J. Fuglevand,et al.  Contractile Properties of Human Motor Units: Is Man a Gat? , 1998 .

[56]  Motor Unit Synchronization Increases EMG Amplitude and Force Fluctuations in Simulated Isometric Contractions. , 1998 .

[57]  J. Semmler,et al.  Motor unit discharge and force tremor in skill- and strength-trained individuals , 1998, Experimental Brain Research.

[58]  D. Troiani,et al.  Nonlinear tension summation of different combinations of motor units in the anesthetized cat peroneus longus muscle. , 1999, Journal of neurophysiology.

[59]  J. R. Rosenberg,et al.  Load-independent contributions from motor-unit synchronization to human physiological tremor. , 1999, Journal of neurophysiology.

[60]  R M Enoka,et al.  Task- and age-dependent variations in steadiness. , 1999, Progress in brain research.