Quantifying lateral tissue heterogeneities in hadron therapy.

In radiotherapy with scanned particle beams, tissue heterogeneities lateral to the beam direction are problematic in two ways: they pose a challenge to dose calculation algorithms, and they lead to a high sensitivity to setup errors. In order to quantify and avoid these problems, a heterogeneity number H(i) as a method to quantify lateral tissue heterogeneities of single beam spot i is introduced. To evaluate this new concept, two kinds of potential errors were investigated for single beam spots: First, the dose calculation error has been obtained by comparing the dose distribution computed by a simple pencil beam algorithm to more accurate Monte Carlo simulations. The resulting error is clearly correlated with H(i). Second, the analysis of the sensitivity to setup errors of single beam spots also showed a dependence on H(i). From this data it is concluded that H(i) can be used as a criterion to assess the risks of a compromised delivered dose due to lateral tissue heterogeneities. Furthermore, a method how to incorporate this information into the inverse planning process for intensity modulated proton therapy is presented. By suppressing beam spots with a high value of H(i), the unfavorable impact of lateral tissue heterogeneities can be reduced, leading to treatment plans which are more robust to dose calculation errors of the pencil beam algorithm. Additional possibilities to use the information of H(i) are outlined in the discussion.

[1]  A. Lomax,et al.  Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.

[2]  Matthias Fippel,et al.  A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations , 2005, Physics in medicine and biology.

[3]  T. Bortfeld,et al.  Inverse planning for photon and proton beams. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[4]  D. Huyskens,et al.  A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  G T Chen,et al.  Degradation of the Bragg peak due to inhomogeneities. , 1986, Physics in medicine and biology.

[6]  Nzhde Agazaryan,et al.  Degeneracy, frequency response and filtering in IMRT optimization. , 2004, Physics in medicine and biology.

[7]  M Goitein,et al.  A pencil beam algorithm for proton dose calculations. , 1996, Physics in medicine and biology.

[8]  Horst W. Hamacher,et al.  A multicriteria optimization approach for inverse radiotherapy planning , 2000 .

[9]  P. Petti,et al.  Differential-pencil-beam dose calculations for charged particles. , 1992, Medical physics.

[10]  E. Pedroni,et al.  Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation. , 1999, Physics in medicine and biology.

[11]  G. Moliere,et al.  Theory of the scattering of fast charged particles. 2. Repeated and multiple scattering , 1948 .

[12]  U. Oelfke,et al.  Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media. , 2002, Physics in medicine and biology.

[13]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[14]  T. Bortfeld,et al.  Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. , 2000, Physics in medicine and biology.

[15]  W. T. Scott,et al.  The Theory of Small-Angle Multiple Scattering of Fast Charged Particles , 1963 .

[16]  Uwe Oelfke,et al.  Inverse planning of intensity modulated proton therapy. , 2004, Zeitschrift fur medizinische Physik.

[17]  P Andreo,et al.  Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization , 1997, Physics in medicine and biology.

[18]  Gert Moliere,et al.  Theorie der Streuung schneller geladener Teilchen II Mehrfach-und Vielfachstreuung , 1948 .