Stable Small Animal Ventilation for Dynamic Lung Imaging to Support Computational Fluid Dynamics Models

Pulmonary computational fluid dynamics models require that three-dimensional images be acquired over multiple points in the dynamic breathing cycle without breath holds or changes in ventilatory mechanics. With small animals, these requirements can result in long imaging times (∼90 minutes), over which lung mechanics, such as compliance, may gradually change if not carefully monitored and controlled. These changes, caused by derecruitment of parenchymal tissue, are manifested as an upward drift in peak inspiratory pressure (PIP) or by changes in the pressure waveform and/or lung volume over the course of the experiment. We demonstrate highly repeatable mechanical ventilation in anesthetized rats over a long duration for dynamic lung x-ray computed tomography (CT) imaging. We describe significant updates to a basic commercial ventilator that was acquired for these experiments. Key to achieving consistent results was the implementation of periodic deep breaths, or sighs, of extended duration to maintain lung recruitment. In addition, continuous monitoring of breath-to-breath pressure and volume waveforms and long-term trends in PIP and flow provide diagnostics of changes in breathing mechanics.

[1]  Kentaro Uesugi,et al.  Development of high-resolution 4D in vivo-CT for visualization of cardiac and respiratory deformations of small animals , 2008, Physics in medicine and biology.

[2]  J. Mead,et al.  RELATION OF VOLUME HISTORY OF LUNGS TO RESPIRATORY MECHANICS IN ANESTHETIZED DOGS , 1959 .

[3]  James P. Carson,et al.  High resolution lung airway cast segmentation with proper topology suitable for computational fluid dynamic simulations , 2010, Comput. Medical Imaging Graph..

[4]  C. Yamashita,et al.  The Effect of Tidal Volume on Systemic Inflammation in Acid-Induced Lung Injury , 2011, Respiration.

[5]  J. Power,et al.  The pulmonary consequences of a deep breath. , 1982, Respiration physiology.

[6]  J. Bates,et al.  Assessment of peripheral lung mechanics , 2008, Respiratory Physiology & Neurobiology.

[7]  A. Coran,et al.  Lung injury produced by moderate lung overinflation in rats. , 1993, Journal of pediatric surgery.

[8]  Xiangmin Jiao,et al.  Adaptive generation of multimaterial grids from imaging data for biomedical Lagrangian fluid–structure simulations , 2010, Biomechanics and modeling in mechanobiology.

[9]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[10]  James P. Carson,et al.  An Automated Self‐Similarity Analysis of the Pulmonary Tree of the Sprague–Dawley Rat , 2008, Anatomical record.

[11]  G Allan Johnson,et al.  Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents , 2005, Magnetic resonance in medicine.

[12]  D. Dreyfuss,et al.  Ventilator-induced lung injury: lessons from experimental studies. , 1998, American journal of respiratory and critical care medicine.

[13]  Jicun Hu,et al.  Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography. , 2004, Academic radiology.

[14]  Geoffrey McLennan,et al.  Lung structure phenotype variation in inbred mouse strains revealed through in vivo micro-CT imaging. , 2010, Journal of applied physiology.

[15]  G Allan Johnson,et al.  Mechanical ventilation for imaging the small animal lung. , 2002, ILAR journal.

[16]  L W Hedlund,et al.  MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging. , 2000, Magnetic resonance imaging.

[17]  S. F. Gottlieb,et al.  Body plethysmograph for respiratory measurements of unanesthetized small animals. , 1962, Journal of applied physiology.

[18]  Ignacio Rodríguez,et al.  A MRI and Polarized Gases Compatible Respirator and Gas Administrator for the Study of the Small Animal Lung: Volume Measurement and Control , 2010, IEEE Transactions on Biomedical Engineering.

[19]  Andrew P. Kuprat,et al.  An anisotropic scale-invariant unstructured mesh generator suitable for volumetric imaging data , 2009, J. Comput. Phys..

[20]  M Drangova,et al.  In vivo characterization of lung morphology and function in anesthetized free-breathing mice using micro-computed tomography. , 2007, Journal of applied physiology.