A New Multi-Mode Perfusion System for Ex Vivo Heart Perfusion Study

Ex vivo heart perfusion has been shown to be an effective means of facilitating the resuscitation and assessment of donor hearts for cardiac transplantation. Over the last ten years however, only a few ex vivo perfusion systems have been developed for this application. While results have been promising, a system capable of facilitating multiple perfusion strategies on the same platform has not yet been realized. In this paper, the design, development and testing of a novel and modular ex vivo perfusion system is described. The system is capable of operating in three unique primary modes: the traditional Langendorff Mode, Pump-Supported Working-Mode, and Passive Afterload Working-Mode. In each mode, physiological hemodynamic parameters can be produced by managing perfusion settings. To evaluate heart viability, six experiments were conducted using porcine hearts and measuring several parameters including: pH, aortic pressure, lactate metabolism, coronary vascular resistance (CVR), and myocardial oxygen consumption. Pressure-volume relationship measurements were used to assess left ventricular contractility in each Working Mode. Hemodynamic and metabolic conditions remained stable and consistent across 4 h of ex vivo heart perfusion on the ex vivo perfusion system, validating the system as a viable platform for future development of novel preservation and assessment strategies.

[1]  E. Proctor,et al.  Preservation of Isolated Heart for 72 Hours , 1968, British medical journal.

[2]  E. Carlson,et al.  The Isolated Perfused Heart and Its Pioneers , 1999 .

[3]  Victor Mor-Avi,et al.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. , 2015, European heart journal cardiovascular Imaging.

[4]  B. Xiang,et al.  A cardioprotective preservation strategy employing ex vivo heart perfusion facilitates successful transplant of donor hearts after cardiocirculatory death. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  E. Bacha,et al.  The influence of hemodilution on outcome after hypothermic cardiopulmonary bypass: results of a randomized trial in infants. , 2003, The Journal of thoracic and cardiovascular surgery.

[6]  S. Germscheid,et al.  Ex vivo perfusion of the swine heart as a method for pre-transplant assessment , 2012, Perfusion.

[7]  O. Langendorff,et al.  Untersuchungen am überlebenden Säugethierherzen , 1895, Archiv für die gesamte Physiologie des Menschen und der Tiere.

[8]  B. Xiang,et al.  A whole blood-based perfusate provides superior preservation of myocardial function during ex vivo heart perfusion. , 2015, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[9]  L. Mao,et al.  Cardiac Pressure-Volume Loop Analysis Using Conductance Catheters in Mice. , 2015, Journal of visualized experiments : JoVE.

[10]  F. Pigula,et al.  Randomized trial of hematocrit 25% versus 35% during hypothermic cardiopulmonary bypass in infant heart surgery. , 2008, The Journal of thoracic and cardiovascular surgery.

[11]  Marcel C M Rutten,et al.  An Ex Vivo Platform to Simulate Cardiac Physiology: A New Dimension for Therapy Development and Assessment , 2011, The International journal of artificial organs.

[12]  S. Buchholz,et al.  Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume—Comparison between in vivo and ex vivo Cardiac Function , 2016, The Thoracic and Cardiovascular Surgeon.

[13]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2012 update: a report from the American Heart Association. , 2012, Circulation.

[14]  Patrizio Lancellotti,et al.  Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. , 2016, European heart journal cardiovascular Imaging.

[15]  Pascal Leprince,et al.  Ex-vivo perfusion of donor hearts for human heart transplantation (PROCEED II): a prospective, open-label, multicentre, randomised non-inferiority trial , 2015, The Lancet.

[16]  A. Poncelet,et al.  Hypothermic continuous machine perfusion enables preservation of energy charge and functional recovery of heart grafts in an ex vivo model of donation following circulatory death. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  P. Macdonald,et al.  Primary Graft Failure after Heart Transplantation , 2011, Journal of transplantation.

[18]  I. Dixon,et al.  Assessment of donor heart viability during ex vivo heart perfusion. , 2015, Canadian journal of physiology and pharmacology.

[19]  Charles A. Taylor,et al.  Development of a Physical Windkessel Module to Re-Create In Vivo Vascular Flow Impedance for In Vitro Experiments , 2011, Cardiovascular engineering and technology.

[20]  Alvaro Rojas-Pena,et al.  Achieving 12 Hour Normothermic Ex Situ Heart Perfusion: An Experience of 40 Porcine Hearts , 2016, ASAIO journal.