Enhanced Sensitivity in Comprehensive Liquid Chromatography: Overcoming the Dilution Problem in LC × LC via Temperature-Responsive Liquid Chromatography.

In comprehensive two-dimensional liquid chromatography (LC × LC), solvents of high eluotropic strength are frequently used in the first dimension (1D), which lead to peak broadening in the second dimension (2D). In the majority of the current LC × LC column combinations, analytes are less than optimally refocused upon transfer to the second column, which negatively affects sensitivity. Furthermore, the typical combination of 1 or 2.1 mm columns in the 1D paired with a 3 mm (or broader) column in the 2D leads to at least a 9- or 4-fold dilution and a corresponding loss of sensitivity when using concentration-sensitive detectors. This occurs due to the enhanced radial dilution of the analytes in a broader column, while the sensitivity problem is further exacerbated in LC × LC due to the high flow operated 2D. In this paper, we introduce a solution to neutralize and inverse this dilution problem through a reconcentrating solution using temperature-responsive liquid chromatography (TRLC) in the 1D, which is a purely aqueous separation mode. Full solute refocusing at the 2D column head is thereby obtained when TRLC is combined with reversed-phase liquid chromatography (RPLC). This is shown for the combination of a 2.1 mm I.D. TRLC column with decreasing RPLC column diameters (3-2.1-1 mm) operated at the same linear velocities, hence a resulting decrease in dilution, respectively. Ultraviolet (UV) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) detection were used to determine the experimental detection limits. Sensitivity improvements with UV detection were somewhat lower than expected, but represent ∼1.5- and 3-fold sensitivity enhancement when using a 1 mm I.D. column compared to 2.1 or 3 mm I.D. columns in the 2D, respectively. This is attributed to extra-column dispersion and the poorer performance of 1 mm I.D. columns. A major benefit of the use of 1 mm I.D. columns in the 2D is that it allows split-free coupling of 2D effluent with ESI-MS (at 450 μL/min), making the coupling robust and simple. When using ESI-MS even better, albeit more variable, sensitivity enhancements were obtained on the narrower columns. The benefits of the methodology are demonstrated for paraben test solutes and for phenolic compounds in a blueberry extract by TRLC × RPLC-UV-ESI-TOF-MS.

[1]  S. Heinisch,et al.  Strategies to circumvent the solvent strength mismatch problem in on-line comprehensive two-dimensional liquid chromatography. , 2021, Journal of separation science.

[2]  F. Lynen,et al.  Pharmaceutical impurity analysis by comprehensive two-dimensional temperature responsive × reversed phase liquid chromatography. , 2020, Journal of chromatography. A.

[3]  T. Lauer,et al.  Numerical and experimental investigation of analyte breakthrough from sampling loops used for multi-dimensional liquid chromatography. , 2020, Journal of chromatography. A.

[4]  O. Schmitz,et al.  Development of a at-column dilution modulator for flexible and precise control of dilution factors to overcome mobile phase incompatibility in comprehensive two-dimensional liquid chromatography. , 2019, Analytical chemistry.

[5]  S. Heinisch,et al.  Quantitative aspects in on-line comprehensive two-dimensional liquid chromatography for pharmaceutical applications. , 2019, Talanta.

[6]  A. de Villiers,et al.  Application of Kinetically Optimised Online HILIC × RP-LC Methods Hyphenated to High Resolution MS for the Analysis of Natural Phenolics , 2018, Chromatographia.

[7]  A. de Villiers,et al.  Predictive kinetic optimisation of hydrophilic interaction chromatography × reversed phase liquid chromatography separations: Experimental verification and application to phenolic analysis. , 2018, Journal of chromatography. A.

[8]  F. Lynen,et al.  Enhancing the Possibilities of Comprehensive Two-Dimensional Liquid Chromatography through Hyphenation of Purely Aqueous Temperature-Responsive and Reversed-Phase Liquid Chromatography. , 2018, Analytical chemistry.

[9]  Peter J Schoenmakers,et al.  Optimizing separations in online comprehensive two‐dimensional liquid chromatography , 2017, Journal of separation science.

[10]  Dwight R Stoll,et al.  Active Solvent Modulation: A Valve-Based Approach To Improve Separation Compatibility in Two-Dimensional Liquid Chromatography. , 2017, Analytical chemistry.

[11]  D. Guillarme,et al.  Comparison of originator and biosimilar therapeutic monoclonal antibodies using comprehensive two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry , 2016, mAbs.

[12]  Harald Pasch,et al.  Recent advances and trends in the liquid-chromatography-mass spectrometry analysis of flavonoids. , 2016, Journal of chromatography. A.

[13]  Peter J. Schoenmakers,et al.  Reducing Dilution and Analysis Time in Online Comprehensive Two-Dimensional Liquid Chromatography by Active Modulation , 2015, Analytical chemistry.

[14]  S. Heinisch,et al.  Optimization of conditions in on-line comprehensive two-dimensional reversed phase liquid chromatography. Experimental comparison with one-dimensional reversed phase liquid chromatography for the separation of peptides. , 2015, Journal of chromatography. A.

[15]  P. Schoenmakers,et al.  Comprehensive Two-Dimensional Liquid Chromatography with Stationary-Phase-Assisted Modulation Coupled to High-Resolution Mass Spectrometry Applied to Proteome Analysis of Saccharomyces cerevisiae. , 2015, Analytical chemistry.

[16]  Y. Guan,et al.  A vacuum assisted dynamic evaporation interface for two-dimensional normal phase/reverse phase liquid chromatography. , 2010, Journal of chromatography. A.

[17]  S. Rutan,et al.  A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time. , 2010, Journal of chromatography. A.

[18]  L. Mondello,et al.  Quantitative characterization of solid epoxy resins using comprehensive two dimensional liquid chromatography coupled with electrospray ionization-time of flight mass spectrometry. , 2009, Analytical chemistry.

[19]  P. Sandra,et al.  Evaluation of the Temperature Responsive Stationary Phase Poly(N-isopropylacrylamide) in Aqueous LC for the Analysis of Small Molecules , 2007 .

[20]  R. Anderegg,et al.  Comprehensive on-line LC/LC/MS of proteins. , 1997, Analytical chemistry.

[21]  D. Harmes,et al.  Evaluation of detection sensitivity in comprehensive two-dimensional liquid chromatography separations of an active pharmaceutical ingredient and its degradants , 2014, Analytical and Bioanalytical Chemistry.

[22]  K. Sandra,et al.  Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests , 2014, Analytical and Bioanalytical Chemistry.