Statistical parametric maps of 18F-FDG PET and 3-D autoradiography in the rat brain: a cross-validation study

PurposeAlthough specific positron emission tomography (PET) scanners have been developed for small animals, spatial resolution remains one of the most critical technical limitations, particularly in the evaluation of the rodent brain. The purpose of the present study was to examine the reliability of voxel-based statistical analysis (Statistical Parametric Mapping, SPM) applied to 18F-fluorodeoxyglucose (FDG) PET images of the rat brain, acquired on a small animal PET not specifically designed for rodents. The gold standard for the validation of the PET results was the autoradiography of the same animals acquired under the same physiological conditions, reconstructed as a 3-D volume and analysed using SPM.MethodsEleven rats were studied under two different conditions: conscious or under inhalatory anaesthesia during 18F-FDG uptake. All animals were studied in vivo under both conditions in a dedicated small animal Philips MOSAIC PET scanner and magnetic resonance images were obtained for subsequent spatial processing. Then, rats were randomly assigned to a conscious or anaesthetized group for postmortem autoradiography, and slices from each animal were aligned and stacked to create a 3-D autoradiographic volume. Finally, differences in 18F-FDG uptake between conscious and anaesthetized states were assessed from PET and autoradiography data by SPM analysis and results were compared.ResultsSPM results of PET and 3-D autoradiography are in good agreement and led to the detection of consistent cortical differences between the conscious and anaesthetized groups, particularly in the bilateral somatosensory cortices. However, SPM analysis of 3-D autoradiography also highlighted differences in the thalamus that were not detected with PET.ConclusionThis study demonstrates that any difference detected with SPM analysis of MOSAIC PET images of rat brain is detected also by the gold standard autoradiographic technique, confirming that this methodology provides reliable results, although partial volume effects might make it difficult to detect slight differences in small regions.

[1]  Soon-Hyun Ahn,et al.  Changes of 2-deoxyglucose uptake in the rat auditory pathway after bilateral ablation of the cochlea , 2004, Hearing Research.

[2]  H. Kung,et al.  In vivo studies of the SERT-selective [18F]FPBM and VMAT2-selective [18F]AV-133 radiotracers in a rat model of Parkinson's disease. , 2010, Nuclear medicine and biology.

[3]  Marc Dhenain,et al.  Detection by voxel-wise statistical analysis of significant changes in regional cerebral glucose uptake in an APP/PS1 transgenic mouse model of Alzheimer's disease , 2010, NeuroImage.

[4]  Maria C. Rodriguez-Oroz,et al.  New MRI, 18F-DOPA and 11C-(+)-α-dihydrotetrabenazine templates for Macaca fascicularis neuroimaging: Advantages to improve PET quantification , 2009, NeuroImage.

[5]  Kwang Suk Park,et al.  Voxel-based statistical analysis of cerebral glucose metabolism in the rat cortical deafness model by 3D reconstruction of brain from autoradiographic images , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[6]  G. Paxinos,et al.  The Rat Brain in Stereotaxic Coordinates , 1983 .

[7]  Joel S. Karp,et al.  Imaging performance of a-PET: a small animal PET camera , 2005, IEEE Transactions on Medical Imaging.

[8]  Jun Yang,et al.  Statistical parametric mapping applied to an autoradiographic study of cerebral activation during treadmill walking in rats , 2004, NeuroImage.

[9]  H. Müller-Gärtner,et al.  Imaging of striatal dopamine D(2) receptors with a PET system for small laboratory animals in comparison with storage phosphor autoradiography: a validation study with (18)F-(N-methyl)benperidol. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Jurgen Seidel,et al.  Measurement of cerebral glucose metabolic rates in the anesthetized rat by dynamic scanning with 18F-FDG, the ATLAS small animal PET scanner, and arterial blood sampling. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Doris J. Doudet,et al.  Evaluation of the Integrity of the Dopamine System in a Rodent Model of Parkinson’s Disease: Small Animal Positron Emission Tomography Compared to Behavioral Assessment and Autoradiography , 2006, Molecular Imaging and Biology.

[12]  Johan Nuyts,et al.  Construction and evaluation of multitracer small-animal PET probabilistic atlases for voxel-based functional mapping of the rat brain. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  Jeih-San Liow,et al.  Absolute quantification of regional cerebral glucose utilization in mice by 18F-FDG small animal PET scanning and 2-14C-DG autoradiography. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  M. Delgado,et al.  Use of 11C-(+)-α-dihydrotetrabenazine for the assessment of dopaminergic innervation in animal models of Parkinson's disease , 2008 .

[15]  Tetsuya Suhara,et al.  Longitudinal, Quantitative Assessment of Amyloid, Neuroinflammation, and Anti-Amyloid Treatment in a Living Mouse Model of Alzheimer's Disease Enabled by Positron Emission Tomography , 2007, The Journal of Neuroscience.

[16]  Anat Biegon,et al.  Metabolic and behavioral deficits following a routine surgical procedure in rats , 2007, Brain Research.

[17]  Marc C. Huisman,et al.  Performance evaluation of the Philips MOSAIC small animal PET scanner , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[18]  Mario Marengo,et al.  Post-Reconstruction Partial Volume Correction of PET Images Using Iterative Deconvolution Algorithm and Anatomical Priors , 2009 .

[19]  D. Eidelberg Metabolic brain networks in neurodegenerative disorders: a functional imaging approach , 2009, Trends in Neurosciences.

[20]  C. Cavada,et al.  Progression of dopaminergic depletion in a model of MPTP-induced Parkinsonism in non-human primates. An 18F-DOPA and 11C-DTBZ PET study , 2010, Neurobiology of Disease.

[21]  Arman Rahmim,et al.  Design and Implementation of an Automated Partial Volume Correction in PET: Application to Dopamine Receptor Quantification in the Normal Human Striatum , 2008, Journal of Nuclear Medicine.

[22]  Koen Van Laere,et al.  Metabolic–dopaminergic mapping of the 6-hydroxydopamine rat model for Parkinson’s disease , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  P. T. Nguyen,et al.  Statistical Parametric Mapping reveals ligand and region-specific activation of G-proteins by CB1 receptors and non-CB1 sites in the 3D reconstructed mouse brain , 2010, NeuroImage.

[24]  Vinal D. Patel,et al.  Metabolic Changes in the Rodent Brain after Acute Administration of Salvinorin A , 2009, Molecular Imaging and Biology.

[25]  G. Bormans,et al.  Type 1 cannabinoid receptor mapping with [18F]MK-9470 PET in the rat brain after quinolinic acid lesion: a comparison to dopamine receptors and glucose metabolism , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[26]  Hank F Kung,et al.  Mass effect of injected dose in small rodent imaging by SPECT and PET. , 2005, Nuclear medicine and biology.

[27]  Vesna Sossi,et al.  Dopamine transporter relation to levodopa‐derived synaptic dopamine in a rat model of Parkinson’s: an in vivo imaging study , 2009, Journal of neurochemistry.

[28]  Vincent Frouin,et al.  Automated Three-Dimensional Analysis of Histological and Autoradiographic Rat Brain Sections: Application to an Activation Study , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[29]  Karl J. Friston,et al.  Statistical parametric maps in functional imaging: A general linear approach , 1994 .

[30]  L. Sokoloff,et al.  Use of [18F]fluorodeoxyglucose and the ATLAS small animal PET scanner to examine cerebral functional activation by whisker stimulation in unanesthetized rats , 2011, Nuclear medicine communications.

[31]  Anthonin Reilhac,et al.  Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method , 2008, NeuroImage.

[32]  C. B. Smith,et al.  Resolution, sensitivity and precision with autoradiography and small animal positron emission tomography: implications for functional brain imaging in animal research. , 2005, Nuclear medicine and biology.

[33]  H. Onoe,et al.  Establishment of In Vivo Brain Imaging Method in Conscious Mice , 2010, Journal of Nuclear Medicine.

[34]  R. Kessler,et al.  Analysis of emission tomographic scan data: limitations imposed by resolution and background. , 1984, Journal of computer assisted tomography.

[35]  Patrick Dupont,et al.  Longitudinal microPET imaging of brain glucose metabolism in rat lithium–pilocarpine model of epilepsy , 2009, Experimental Neurology.

[36]  M. C. Rodríguez-Oroz,et al.  Utilización de la 11C-(+)-α-dihidrotetrabenazina para la evaluación de la inervación dopaminérgica en modelos animales de la enfermedad de Parkinson , 2008 .

[37]  Zang-Hee Cho,et al.  Neural responses in rat brain during acute immobilization stress: A [F-18]FDG micro PET imaging study , 2009, NeuroImage.

[38]  Jesper L. R. Andersson,et al.  A template for spatial normalisation of MR images of the rat brain , 2003, Journal of Neuroscience Methods.