Cloud-Based CT Dose Monitoring using the DICOM-Structured Report: Fully Automated Analysis in Regard to National Diagnostic Reference Levels

PURPOSE To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). MATERIALS AND METHODS We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDIvol) and dose length product (DLP). RESULTS Data of 36,523 examinations (131,527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDIvol and DLP were 51.3% and 52.8% of the national DRLs, respectively. CTDIvol and DLP reached 43.8% and 43.1% for abdominal CT (n=10,590), 66.6% and 69.6% for cranial CT (n=16,098) and 37.8% and 44.0% for chest CT (n=10,387) of the compared national DRLs, respectively. Overall, the CTDIvol exceeded national DRLs in 1.9% of the examinations, while the DLP exceeded national DRLs in 2.9% of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50% of the DRLs. CONCLUSION The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50% of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments. KEY POINTS • The newly developed software based on the DICOM-Structured Report enables large-scale cloud-based CT dose monitoring • The implemented software solution enables automated benchmarking in regard to national DRLs • The local radiation exposure from CT reached approximately 50 % of the national DRLs • The cloud-based approach offers great potential for multi-center dose analysis.

[1]  P C Shrimpton,et al.  National survey of doses from CT in the UK: 2003. , 2006, The British journal of radiology.

[2]  Jaydev K Dave,et al.  Extraction of CT dose information from DICOM metadata: automated Matlab-based approach. , 2013, AJR. American journal of roentgenology.

[3]  Franz Quehenberger,et al.  The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT. , 2014, European journal of radiology.

[4]  T. Dowdell,et al.  Identifying Institutional Diagnostic Reference Levels for CT with Radiation Dose Index Monitoring Software. , 2015, Radiology.

[5]  R. Zeman,et al.  Diagnostic reference levels from the ACR CT Accreditation Program. , 2011, Journal of the American College of Radiology : JACR.

[6]  M. Prokop,et al.  A national survey on radiation dose in CT in The Netherlands , 2013, Insights into Imaging.

[7]  Andrew D. A. Maidment,et al.  RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.

[8]  I. Elbakri,et al.  Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience , 2013, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[9]  A. Lukasiewicz,et al.  Radiation dose index of renal colic protocol CT studies in the United States: a report from the American College of Radiology National Radiology Data Registry. , 2014, Radiology.

[10]  K Faulkner,et al.  On the use of DICOM cine header information for optimisation: results from the 2002 European DIMOND cardiology survey. , 2005, Radiation protection dosimetry.

[11]  M. McEntee,et al.  The establishment of computed tomography diagnostic reference levels in Portugal. , 2014, Radiation protection dosimetry.

[12]  M. McEntee,et al.  Establishment of CT diagnostic reference levels in Ireland. , 2012, The British journal of radiology.

[13]  S. Nosaka,et al.  Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children’s hospital , 2015, Pediatric Radiology.

[14]  Gerald Antoch,et al.  Dose monitoring using the DICOM structured report: assessment of the relationship between cumulative radiation exposure and BMI in abdominal CT. , 2015, Clinical radiology.

[15]  F R Verdun,et al.  Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels. , 2010, Radiation protection dosimetry.