Computer-controlled portable stimulator for paraplegic patients.

A six-channel lightweight, portable and computer-controlled stimulator for the functional activation of paraplegic patients is described. To enable programming of the various functions, the stimulator was designed to work in a remote-control mode hosted by an IBM PC or compatible computer, in addition to its normally used local mode. The stimulus parameters, including current intensity, stimulus frequency and pulse width, are individually adjustable and programmable for each channel. The power source is 12 V 500 m Ah-1, from 10 rechargeable nickel cadmium batteries, with a run time of 1.5 h for a load of 200 mA in four channels. Various training programmes for the activation of paraplegics in the sitting, standing and walking positions are described. The final design of the stimulator is based on experience gained from 25 patients, treated and evaluated during the course of development. Ongoing work including clinical, biomechanical and physiological studies is carried out to evaluate performance of the activated patients and to optimize stimulation.

[1]  E. Isakov,et al.  Biomechanical and physiological evaluation of FES-activated paraplegic patients. , 1986, Journal of rehabilitation research and development.

[2]  A. Kralj,et al.  Programmed Six-Channel Electrical Stimulator for Complex Stimulation of Leg Muscles During Walking , 1979, IEEE Transactions on Biomedical Engineering.

[3]  T. van Eijden,et al.  Forces acting on the patella during maximal voluntary contraction of the quadriceps femoris muscle at different knee flexion/extension angles. , 1987, Acta anatomica.

[4]  Y. Itzchak,et al.  In vivo 31P NMR studies of paraplegics' muscles activated by functional electrical stimulation , 1993, Magnetic resonance in medicine.

[5]  T Bajd,et al.  Use of a two-channel functional electrical stimulator to stand paraplegic patients. , 1981, Physical therapy.

[6]  J Mizrahi,et al.  Recruitment, force and fatigue characteristics of quadriceps muscles of paraplegics isometrically activated by surface functional electrical stimulation. , 1990, Journal of biomedical engineering.

[7]  A Biomechanical Study of Muscle Torque as Affected by Motor Unit Activity, Length-Tension Relationship and Muscle Force Lever , 1973 .

[8]  T. Fahey,et al.  Influence of sex differences and knee joint position on electrical stimulation-modulated strength increases. , 1985, Medicine and science in sports and exercise.

[9]  G. Yarkony,et al.  Standing the spinal cord injured patient by electrical stimulation: refinement of a protocol for clinical use , 1989, IEEE Transactions on Biomedical Engineering.

[10]  T. Bajd,et al.  The use of a four-channel electrical stimulator as an ambulatory aid for paraplegic patients. , 1983, Physical therapy.

[11]  D. M. Selkowitz Improvement in isometric strength of the quadriceps femoris muscle after training with electrical stimulation. , 1985, Physical therapy.

[12]  R. Kobetic,et al.  Development and operation of portable and laboratory electrical stimulation systems for walking in paraplegic subjects , 1989, IEEE Transactions on Biomedical Engineering.

[13]  Energy cost and physiological reactions to effort during activation of paraplegics by functional electrical stimulation. , 1985, Scandinavian journal of rehabilitation medicine. Supplement.