Is tomotherapy the future of IMRT?

Intensity-modulated radiotherapy (IMRT) has become established in many clinics round the world and is, arguably, technically feasible in any facility. Serial tomotherapy contributed an extensive role in its introduction into the mainstream in the second half of the 1990s. In tomotherapy, literally "slice therapy", highly conformal treatments are possible because of the advantages available within the treatment planning of the IMRT process. Currently the majority of clinics implementing IMRT are doing so using conventional clinical linear accelerators (Linacs) fitted with an integrated multileaf collimator (MLC). At this point in time we may wonder if there is any scope for further dramatic changes in this new technology. As we venture from IMRT initial implementation into image guided therapy it is clear that major changes in approach are still valid and needed. If, at each treatment fraction, we can ensure that treatments are delivered accurately by integration of volumetric imaging into on-line validation, then we can attempt higher levels of conformality. A new treatment machine, the helical tomotherapy system, is available that combines the benefits of tomotherapy with on-line volumetric imaging. In this article we will review this approach and explore its features.

[1]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[2]  C H Clark,et al.  Implementation of IMRT in the radiotherapy department. , 2003, The British journal of radiology.

[3]  D. Yan,et al.  Reducing uncertainties in volumetric image based deformable organ registration. , 2003, Medical physics.

[4]  J. Kapatoes,et al.  On the accuracy and effectiveness of dose reconstruction for tomotherapy. , 2001, Physics in medicine and biology.

[5]  A. Poynter,et al.  Practical experience with intensity-modulated radiotherapy. , 2004, The British journal of radiology.

[6]  William Main,et al.  An Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System , 2003, Neurosurgery.

[7]  A. D'Amico,et al.  Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging. , 2001, Medical physics.

[8]  Andrew Jackson,et al.  Intensity-modulated radiotherapy. , 2002, Cancer journal.

[9]  D M Shepard,et al.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. , 2002, Medical physics.

[10]  A W Beavis,et al.  Radiotherapy treatment planning of brain tumours using MRI alone. , 1998, The British journal of radiology.

[11]  D. Verellen,et al.  Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region. , 1997, International journal of radiation oncology, biology, physics.

[12]  James A. Purdy,et al.  Intensity-modulated radiotherapy: current status and issues of interest. , 2001, International journal of radiation oncology, biology, physics.

[13]  Mark P. Carol,et al.  Peacock™: A system for planning and rotational delivery of intensity‐modulated fields , 1995, Int. J. Imaging Syst. Technol..

[14]  W. De Gersem,et al.  An anatomy-based beam segmentation tool for intensity-modulated radiation therapy and its application to head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.

[15]  S. Webb The physical basis of IMRT and inverse planning. , 2003, The British journal of radiology.

[16]  J Kim,et al.  A feasibility study of mutual information based setup error estimation for radiotherapy. , 2001, Medical physics.

[17]  David A Jaffray,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation : an alternative to tomotherapy , 2002 .

[18]  O Sauer,et al.  A simple model for examining issues in radiotherapy optimization. , 1999, Medical physics.

[19]  C. Nutting,et al.  Clinical use of intensity-modulated radiotherapy: part I. , 2004, The British journal of radiology.

[20]  J. Adler,et al.  CyberKnife Radiotherapy for Localized Prostate Cancer: Rationale and Technical Feasibility , 2003, Technology in cancer research & treatment.

[21]  A W Beavis,et al.  Optimization of the step-and-shoot leaf sequence for delivery of intensity modulated radiation therapy using a variable division scheme. , 2001, Physics in medicine and biology.

[22]  Lisa Grimm,et al.  Commissioning and Clinical Implementation of a Sliding Gantry CT Scanner Installed in an Existing Treatment Room and Early Clinical Experience for Precise Tumor Localization , 2003, American journal of clinical oncology.

[23]  M. Alber,et al.  Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. , 2001, Physics in medicine and biology.

[24]  Dirk Verellen,et al.  Considerations on treatment efficiency of different conformal radiation therapy techniques for prostate cancer. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  M. Mackenzie,et al.  Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields. , 2002, Medical physics.

[26]  P. C. Williams IMRT: delivery techniques and quality assurance. , 2003, The British journal of radiology.

[27]  Marcel van Herk,et al.  Evaluation of cost functions for gray value matching of two-dimensional images in radiotherapy. , 2003, Medical physics.

[28]  F. Lohr,et al.  Comparison of intensity-modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors. , 2000, International journal of radiation oncology, biology, physics.

[29]  J. Deasy,et al.  Beyond bixels: generalizing the optimization parameters for intensity modulated radiation therapy. , 2002, Medical physics.

[30]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  B. Paliwal,et al.  Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapy. , 1997, Medical physics.

[32]  Radhe Mohan,et al.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. , 2003, Medical physics.

[33]  Steven D Chang,et al.  Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions , 2001, Neurosurgery.

[34]  C. Meyer,et al.  Automated generation of a four-dimensional model of the liver using warping and mutual information. , 2003, Medical physics.

[35]  Tom Depuydt,et al.  The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[36]  J. Kapatoes,et al.  Limited-data image registration for radiotherapy positioning and verification. , 2002, International journal of radiation oncology, biology, physics.

[37]  C. Nutting,et al.  Clinical use of intensity-modulated radiotherapy: part II. , 2004, The British journal of radiology.

[38]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[39]  D. Low,et al.  Quality assurance of serial tomotherapy for head and neck patient treatments. , 1998, International journal of radiation oncology, biology, physics.

[40]  Gustavo H Olivera,et al.  Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images. , 2002, Medical physics.