A Photovoltaic-Driven and Energy-Autonomous CMOS Implantable Sensor

An energy-autonomous, photovoltaic (PV)-driven and MRI-compatible CMOS implantable sensor is presented. On-chip P+/N-well diode arrays are used as CMOS-compatible PV cells to harvest μW's of power from the light that penetrates into the tissue. In this 2.5 mm × 2.5 mm sub-μW integrated system, the in-vivo physiological signals are first measured by using a subthreshold ring oscillator-based sensor, the acquired data is then modulated into a frequency-shift keying (FSK) signal, and finally transmitted neuromorphically to the skin surface by using a pair of polarized electrodes.

[1]  Teresa H. Y. Meng,et al.  HermesB: A Continuous Neural Recording System for Freely Behaving Primates , 2007, IEEE Transactions on Biomedical Engineering.

[2]  Shuichi Shoji,et al.  A very low-power consumption wireless ECG monitoring system using body as a signal transmission medium , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[3]  G. Vermeeren,et al.  Path loss model for in-body communication in homogeneous human muscle tissue , 2009 .

[4]  Rajeevan Amirtharajah,et al.  Integrated Solar Energy Harvesting and Storage , 2009, IEEE Transactions on Very Large Scale Integration (VLSI) Systems.

[5]  W. Ko,et al.  Intracranial Pressure Telemetry System Using Semicustom Integrated Circuits , 1986, IEEE Transactions on Biomedical Engineering.

[6]  Gregory K. Chen Millimeter-scale nearly perpetual sensor system , 2010 .

[7]  Jamil Y. Khan,et al.  Wireless Body Sensor Network Using Medical Implant Band , 2007, Journal of Medical Systems.

[8]  J W Knutti,et al.  Integrated power controllers and RF data transmitters for totally implantable telemetry. , 1979, Biotelemetry and patient monitoring.

[9]  R. Dutton,et al.  Comprehensive study of noise processes in electrode electrolyte interfaces , 2004 .

[10]  K. Wise,et al.  An implantable CMOS circuit interface for multiplexed microelectrode recording arrays , 1992 .

[11]  J.D. Meindl,et al.  A monolithic signal processor for a neurophysiological telemetry system , 1985, IEEE Journal of Solid-State Circuits.

[12]  Brian P. Otis,et al.  A 2.3μW wireless intraocular pressure/temperature monitor , 2011, 2010 IEEE Asian Solid-State Circuits Conference.

[13]  John M. Hollerbach,et al.  An integrated tactile and thermal sensor , 1986, Proceedings. 1986 IEEE International Conference on Robotics and Automation.

[14]  Howard A. Frank,et al.  Long-Term Electric Stimulation of the Heart for Stokes-Adams Disease , 1961 .

[15]  K. König,et al.  Multiphoton microscopy in life sciences , 2000, Journal of microscopy.

[16]  A. Hastings The Art of Analog Layout , 2000 .

[17]  P. Jacobs,et al.  Design optimisation of planar electrolytic conductivity sensors , 2006, Medical and Biological Engineering and Computing.

[18]  J. D. Munck,et al.  The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. , 1999, Physiological measurement.

[19]  Tayfun Akin,et al.  A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode , 1998, IEEE J. Solid State Circuits.

[20]  Dennis D. Roscoe,et al.  An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle , 1987, IEEE Transactions on Biomedical Engineering.

[21]  Maysam Ghovanloo,et al.  Optimization of Data Coils in a Multiband Wireless Link for Neuroprosthetic Implantable Devices , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[22]  이태형,et al.  An Implantable Multichannel Stimulating Circuit for Neural Stimulator , 2009 .

[23]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .

[24]  H. Ronkainen,et al.  Monolithic SOI-MEMS capacitive pressure sensor with standard bulk CMOS readout circuit , 2003, ESSCIRC 2004 - 29th European Solid-State Circuits Conference (IEEE Cat. No.03EX705).