Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models

Anthropomorphic computational phantoms are computer models of the human body for use in the evaluation of dose distributions resulting from either internal or external radiation sources. Currently, two classes of computational phantoms have been developed and widely utilized for organ dose assessment: (1) stylized phantoms and (2) voxel phantoms which describe the human anatomy via mathematical surface equations or 3D voxel matrices, respectively. Although stylized phantoms based on mathematical equations can be very flexible in regard to making changes in organ position and geometrical shape, they are limited in their ability to fully capture the anatomic complexities of human internal anatomy. In turn, voxel phantoms have been developed through image-based segmentation and correspondingly provide much better anatomical realism in comparison to simpler stylized phantoms. However, they themselves are limited in defining organs presented in low contrast within either magnetic resonance or computed tomography images-the two major sources in voxel phantom construction. By definition, voxel phantoms are typically constructed via segmentation of transaxial images, and thus while fine anatomic features are seen in this viewing plane, slice-to-slice discontinuities become apparent in viewing the anatomy of voxel phantoms in the sagittal or coronal planes. This study introduces the concept of a hybrid computational newborn phantom that takes full advantage of the best features of both its stylized and voxel counterparts: flexibility in phantom alterations and anatomic realism. Non-uniform rational B-spline (NURBS) surfaces, a mathematical modeling tool traditionally applied to graphical animation studies, was adopted to replace the limited mathematical surface equations of stylized phantoms. A previously developed whole-body voxel phantom of the newborn female was utilized as a realistic anatomical framework for hybrid phantom construction. The construction of a hybrid phantom is performed in three steps: polygonization of the voxel phantom, organ modeling via NURBS surfaces and phantom voxelization. Two 3D graphic tools, 3D-DOCTOR and Rhinoceros, were utilized to polygonize the newborn voxel phantom and generate NURBS surfaces, while an in-house MATLAB code was used to voxelize the resulting NURBS model into a final computational phantom ready for use in Monte Carlo radiation transport calculations. A total of 126 anatomical organ and tissue models, including 38 skeletal sites and 31 cartilage sites, were described within the hybrid phantom using either NURBS or polygon surfaces. A male hybrid newborn phantom was constructed following the development of the female phantom through the replacement of female-specific organs with male-specific organs. The outer body contour and internal anatomy of the NURBS-based phantoms were adjusted to match anthropometric and reference newborn data reported by the International Commission on Radiological Protection in their Publication 89. The voxelization process was designed to accurately convert NURBS models to a voxel phantom with minimum volumetric change. A sensitivity study was additionally performed to better understand how the meshing tolerance and voxel resolution would affect volumetric changes between the hybrid-NURBS and hybrid-voxel phantoms. The male and female hybrid-NURBS phantoms were constructed in a manner so that all internal organs approached their ICRP reference masses to within 1%, with the exception of the skin (-6.5% relative error) and brain (-15.4% relative error). Both hybrid-voxel phantoms were constructed with an isotropic voxel resolution of 0.663 mm--equivalent to the ICRP 89 reference thickness of the newborn skin (dermis and epidermis). Hybrid-NURBS phantoms used to create their voxel counterpart retain the non-uniform scalability of stylized phantoms, while maintaining the anatomic realism of segmented voxel phantoms with respect to organ shape, depth and inter-organ positioning.

[1]  J. Valentin,et al.  Human Alimentary Tract Model for Radiological Protection , 2006 .

[2]  W E Bolch,et al.  A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology. , 2003, Physics in medicine and biology.

[3]  J. W. Vieira,et al.  MAX meets ADAM: a dosimetric comparison between a voxel-based and a mathematical model for external exposure to photons. , 2004, Physics in medicine and biology.

[4]  Wesley E Bolch,et al.  Whole-body voxel phantoms of paediatric patients—UF Series B , 2006, Physics in medicine and biology.

[5]  P. Dimbylow Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields , 2005, Physics in medicine and biology.

[6]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[7]  Benjamin M. W. Tsui,et al.  Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms , 1999 .

[8]  W E Bolch,et al.  Creation of two tomographic voxel models of paediatric patients in the first year of life. , 2002, Physics in medicine and biology.

[9]  N Petoussi-Henss,et al.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models , 2002, Physics in medicine and biology.

[10]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[11]  Keith F. Eckerman,et al.  Mathematical models and specific absorbed fractions of photon energy in the nonpregnant adult female and at the end of each trimester of pregnancy , 1995 .

[12]  S S Yang,et al.  Correlation of head circumference and crown-rump length in newborn infants. A potential indicator of congenital maldevelopment. , 1975, Biology of the neonate.

[13]  N Petoussi-Henss,et al.  The application of voxel phantoms to the internal dosimetry of radionuclides. , 2003, Radiation protection dosimetry.

[14]  J. W. Vieira,et al.  Comparison between effective doses for voxel-based and stylized exposure models from photon and electron irradiation , 2005, Physics in medicine and biology.

[15]  Shu-xin Zhang,et al.  An Atlas of Histology , 1999 .

[16]  X. Xu,et al.  Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emitters. , 2001, Physics in medicine and biology.

[17]  Les A. Piegl,et al.  On NURBS: A Survey , 2004 .

[18]  T. Nagaoka,et al.  Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. , 2004, Physics in medicine and biology.

[19]  M. King,et al.  A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging. , 1999, Medical physics.

[20]  J. W. Vieira,et al.  All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry. , 2003, Physics in medicine and biology.

[21]  W. Segars,et al.  Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom , 2001 .

[22]  M G Stabin,et al.  PHOTON SPECIFIC ABSORBED FRACTIONS CALCULATED IN THE TRUNK OF AN ADULT MALE VOXEL-BASED PHANTOM , 2002, Health physics.

[23]  Wesley E Bolch,et al.  REVISIONS TO THE ORNL SERIES OF ADULT AND PEDIATRIC COMPUTATIONAL PHANTOMS FOR USE WITH THE MIRD SCHEMA , 2006, Health physics.

[24]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and environmental biophysics.

[25]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[26]  Eric C. Frey,et al.  Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy , 1993 .

[27]  Jai-Ki Lee,et al.  Development of the two Korean adult tomographic computational phantoms for organ dosimetry. , 2006, Medical physics.

[28]  D. G. Jones A Realistic Anthrompomorphic Phantom for Calculating Specific Absorbed Fractions of Energy Deposited from Internal Gamma Emitters , 1998 .

[29]  Wesley E Bolch,et al.  Organ and effective doses in newborns and infants undergoing voiding cystourethrograms (VCUG): a comparison of stylized and tomographic phantoms. , 2006, Medical physics.

[30]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[31]  Icrp Human Respiratory Tract Model for Radiological Protection , 1994 .

[32]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[33]  Wesley E Bolch,et al.  A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography. , 2006, Medical physics.

[34]  N Petoussi-Henss,et al.  ADULT FEMALE VOXEL MODELS OF DIFFERENT STATURE AND PHOTON CONVERSION COEFFICIENTS FOR RADIATION PROTECTION , 2004, Health physics.

[35]  G Gualdrini,et al.  An improved MCNP version of the NORMAN voxel phantom for dosimetry studies , 2005, Physics in medicine and biology.

[36]  Wesley E Bolch,et al.  Age-dependent organ and effective dose coefficients for external photons: a comparison of stylized and voxel-based paediatric phantoms , 2006, Physics in medicine and biology.

[37]  M. Zankl,et al.  Voxel Anthropomorphic Models as a Tool for Internal Dosimetry , 1998 .

[38]  N Petoussi-Henss,et al.  Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures , 2007, Physics in medicine and biology.