Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor

Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness (Th), contraction time (Tc), contraction velocity (Vc), sustain time (Ts), and half-relaxation (Tr) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters (Th, Tc, Vc, Ts, and Tr) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties.

[1]  Honghai Liu,et al.  Comparative Analysis of Wearable A-Mode Ultrasound and sEMG for Muscle-Computer Interface , 2019, IEEE Transactions on Biomedical Engineering.

[2]  Mark I. Johnson,et al.  The effect of inter-electrode distance on radial muscle displacement and contraction time of the biceps femoris, gastrocnemius medialis and biceps brachii, using tensiomyography in healthy participants , 2019, Physiological measurement.

[3]  Yuu Ono,et al.  Estimation of wrist flexion angle from muscle thickness changes measured by a flexible ultrasonic sensor , 2016, 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).

[4]  Pascal Madeleine,et al.  A comparison between mechanomyographic condenser microphone and accelerometer measurements during submaximal isometric, concentric and eccentric contractions. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  E. Alentorn-Geli,et al.  Assessment of neuromuscular risk factors for anterior cruciate ligament injury through tensiomyography in male soccer players , 2015, Knee Surgery, Sports Traumatology, Arthroscopy.

[6]  C. K. Lam,et al.  A systematic review of muscle activity assessment of the biceps brachii muscle using mechanomyography , 2018, Journal of musculoskeletal & neuronal interactions.

[7]  C. Raeder,et al.  Muscle mechanical properties of strength and endurance athletes and changes after one week of intensive training. , 2016, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[8]  Travis W Beck,et al.  Linearity and reliability of the mechanomyographic amplitude versus dynamic torque relationships for the superficial quadriceps femoris muscles , 2010, Muscle & nerve.

[9]  Massimo De Vittorio,et al.  Piezoelectric ultrasonic transducer based on flexible AlN , 2014 .

[10]  Bostjan Simunic,et al.  Short-term repeatability of parameters extracted from radial displacement of muscle belly. , 2008, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[11]  C. Raeder,et al.  Tensiomyographic Markers Are Not Sensitive for Monitoring Muscle Fatigue in Elite Youth Athletes: A Pilot Study , 2017, Front. Physiol..

[12]  C. Raeder,et al.  Tensiomyography reliability and prediction of changes in muscle force following heavy eccentric strength exercise using muscle mechanical properties , 2015 .

[13]  Ó. García-García,et al.  Clinical utility of tensiomyography for muscle function analysis in athletes , 2019, Open access journal of sports medicine.

[14]  T. Kitawaki,et al.  Mathematical equation of fusion index of tetanic contraction of skeletal muscles. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[15]  B. Thompson,et al.  A-mode and B-mode ultrasound measurement of fat thickness: a cadaver validation study , 2019, European Journal of Clinical Nutrition.

[16]  Robert D Herbert,et al.  Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review. , 2013, Journal of applied physiology.

[17]  Jeffrey R Stout,et al.  Reliability of mechanomyographic amplitude and mean power frequency during isometric step and ramp muscle actions , 2008, Journal of Neuroscience Methods.

[18]  Ching-Hsiang Cheng,et al.  A novel flexible capacitive micromachined ultrasonic transducer (CMUT) array with isolated metallic islands riveted to a polymer film , 2013, The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems.

[19]  Honghai Liu,et al.  Muscle fatigue assessment using one-channel single-element ultrasound transducer , 2017, 2017 8th International IEEE/EMBS Conference on Neural Engineering (NER).

[20]  Susanna Rampichini,et al.  Novel insights into skeletal muscle function by mechanomyography: from the laboratory to the field , 2015, Sport Sciences for Health.

[21]  T. Moritani,et al.  Assessment of lower-back muscle fatigue using electromyography, mechanomyography, and near-infrared spectroscopy , 2001, European Journal of Applied Physiology.

[22]  Nur Azah Hamzaid,et al.  Mechanomyography and muscle function assessment: a review of current state and prospects. , 2014, Clinical biomechanics.

[23]  Malcolm M Fairweather,et al.  Assessment of eccentric exercise-induced muscle damage of the elbow flexors by tensiomyography. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[24]  Takanori Uchiyama,et al.  System identification of mechanomyograms detected with an acceleration sensor and a laser displacement meter , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Hong-Bo Xie,et al.  Modeling the relationship between wrist angle and muscle thickness during wrist flexion-extension based on the bone-muscle lever system: a comparison study. , 2009, Medical engineering & physics.

[26]  Plyometric exercise improves jumping performance and skeletal muscle contractile properties in seniors , 2019, Journal of musculoskeletal & neuronal interactions.

[27]  J. Plummer,et al.  On the Generation of High-Frequency Acoustic Energy with Polyvinylidene Fluoride , 1980, IEEE Transactions on Sonics and Ultrasonics.

[28]  He Tian,et al.  A flexible piezoelectric micromachined ultrasound transducer , 2013 .

[29]  Jing-Yi Guo,et al.  Sonomyography (SMG) control for powered prosthetic hand: a study with normal subjects. , 2010, Ultrasound in medicine & biology.

[30]  E. Barreiro,et al.  Respiratory and Limb Muscle Dysfunction in COPD , 2015, COPD.

[31]  Xin Zhao,et al.  Sonomyography Analysis on Thickness of Skeletal Muscle During Dynamic Contraction Induced by Neuromuscular Electrical Stimulation: A Pilot Study , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[32]  Rado Pišot,et al.  Whole muscle contractile parameters and thickness loss during 35-day bed rest , 2008, European Journal of Applied Physiology.

[33]  Christian Than,et al.  The effect of exercise hypertrophy and disuse atrophy on muscle contractile properties: a mechanomyographic analysis , 2016, European Journal of Applied Physiology.

[34]  E. Alentorn-Geli,et al.  Assessment of gastrocnemius tensiomyographic neuromuscular characteristics as risk factors for anterior cruciate ligament injury in male soccer players , 2015, Knee Surgery, Sports Traumatology, Arthroscopy.

[35]  Patrick Gaydecki,et al.  Within-day and between-days reliability of quadriceps isometric muscle fatigue using mechanomyography on healthy subjects. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[36]  M. Fairweather,et al.  Reduced Radial Displacement of the Gastrocnemius Medialis Muscle After Electrically Elicited Fatigue. , 2016, Journal of sport rehabilitation.

[37]  M. Watakabe,et al.  Acoustic and electrical activities during voluntary isometric contraction of biceps brachii muscles in patients with spastic cerebral palsy , 1996, Muscle & nerve.

[38]  Manas Agarwal,et al.  Wearable Ultrasonic Sensor Using Double-Layer PVDF Films for Monitoring Tissue Motion , 2018, 2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE).

[39]  V. Drory,et al.  Muscle thickness measured by ultrasound is reduced in neuromuscular disorders and correlates with clinical and electrophysiological findings , 2019, Muscle & nerve.

[40]  Malcolm M Fairweather,et al.  Long-term stability of tensiomyography measured under different muscle conditions. , 2013, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[41]  Mamun Bin Ibne Reaz,et al.  Surface Electromyography Signal Processing and Classification Techniques , 2013, Sensors.

[42]  Joan Lobo-Prat,et al.  Non-invasive control interfaces for intention detection in active movement-assistive devices , 2014, Journal of NeuroEngineering and Rehabilitation.

[43]  Mechanomyographic Measures of Muscle Contractile Properties are Influenced by Electrode Size and Stimulation Pulse Duration , 2020, Scientific Reports.

[44]  Y. Ono,et al.  Estimation of Tissue Thickness Changes Due to Electrical Muscle Stimulation Using Wearable Ultrasonic Sensor in Pulse Echo Mode , 2019, 2019 IEEE SENSORS.

[45]  Zeljko Zilic,et al.  Ultrasound Sensors for Diaphragm Motion Tracking: An Application in Non-Invasive Respiratory Monitoring , 2018, Sensors.

[46]  Michael Kellmann,et al.  Markers for Routine Assessment of Fatigue and Recovery in Male and Female Team Sport Athletes during High-Intensity Interval Training , 2015, PloS one.

[47]  Reliability of the Electromechanical Delay Components Assessment during the Relaxation Phase , 2013 .

[48]  Jason M DeFreitas,et al.  The linearity and reliability of the mechanomyographic amplitude versus submaximal isometric force relationship , 2009, Physiological measurement.

[49]  I. Loturco,et al.  Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review , 2017, Journal of strength and conditioning research.

[50]  N. Maffiuletti,et al.  Relationship between skeletal muscle contractile properties and power production capacity in female Olympic rugby players , 2018, European journal of sport science.

[51]  Claudio Orizio,et al.  Changes of the force-frequency relationship in human tibialis anterior at fatigue. , 2004, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[52]  Ibrahim AlMohimeed,et al.  Development of wearable and flexible ultrasonic sensor for skeletal muscle monitoring , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[53]  Fábio Mícolis de Azevedo,et al.  The Relationship Between Electromyography and Muscle Force , 2012 .

[54]  C. Orizio,et al.  Surface mechanomyogram reflects muscle fibres twitches summation. , 1996, Journal of biomechanics.

[55]  Test-retest reliability of laser displacement mechanomyography in paraspinal muscles while in lumbar extension or flexion. , 2018, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[56]  Qifa Zhou,et al.  Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces , 2018, Science Advances.

[57]  E. R. Brown,et al.  Conformal Ultrasound Imaging System , 2011 .

[58]  Robert Riener,et al.  A survey of sensor fusion methods in wearable robotics , 2015, Robotics Auton. Syst..

[59]  Kenneth R. Lyons,et al.  Upper Limb Prosthesis Control for High-Level Amputees via Myoelectric Recognition of Leg Gestures , 2018, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[60]  J. Wakeling,et al.  Spectral properties of electromyographic and mechanomyographic signals during dynamic concentric and eccentric contractions of the human biceps brachii muscle. , 2011, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[61]  M. J. Hartman,et al.  Inter-individual variability in the torque-related patterns of responses for mechanomyographic amplitude and mean power frequency , 2007, Journal of Neuroscience Methods.

[62]  M. Quiroga,et al.  Assessment of muscle fatigue after an ultra-endurance triathlon using tensiomyography (TMG) , 2011, Journal of sports sciences.

[63]  V. Valencic,et al.  Measuring of skeletal muscles' dynamic properties. , 1997, Artificial organs.

[64]  S. Gandevia,et al.  Measurement of muscle contraction with ultrasound imaging , 2003, Muscle & nerve.

[65]  Jing-Yi Guo,et al.  Sonomyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle , 2011, European Journal of Applied Physiology.

[66]  Jing-Yi Guo,et al.  Performances of one-dimensional sonomyography and surface electromyography in tracking guided patterns of wrist extension. , 2009, Ultrasound in medicine & biology.

[67]  F. Nakamura,et al.  Differences in Muscle Mechanical Properties Between Elite Power and Endurance Athletes: A Comparative Study , 2015, Journal of strength and conditioning research.

[68]  Y. Ono,et al.  Ultrasonic monitoring of skeletal muscle response to electrical stimulation of peripheral nerve , 2014, 2014 IEEE International Ultrasonics Symposium.

[69]  A O Posatskiy,et al.  The effects of motion artifact on mechanomyography: A comparative study of microphones and accelerometers. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[70]  Yongjin Zhou,et al.  Ultrasonic Measurement of Dynamic Muscle Behavior for Poststroke Hemiparetic Gait , 2017, BioMed research international.

[71]  M. Kraft,et al.  Flexible Soi-Based Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays , 2019, 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII).

[72]  S. Rajan,et al.  Continuous measurement of arterial diameter using wearable and flexible ultrasonic sensor , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[73]  Lei Wang,et al.  The Sensitive and Efficient Detection of Quadriceps Muscle Thickness Changes in Cross-Sectional Plane Using Ultrasonography: A Feasibility Investigation , 2014, IEEE Journal of Biomedical and Health Informatics.

[74]  Honghai Liu,et al.  A New Wearable Ultrasound Muscle Activity Sensing System for Dexterous Prosthetic Control , 2015, 2015 IEEE International Conference on Systems, Man, and Cybernetics.

[75]  J. L. Whittaker,et al.  Ultrasound imaging and muscle function. , 2011, The Journal of orthopaedic and sports physical therapy.

[76]  Joseph P Weir,et al.  Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[77]  Hisao Oka,et al.  Estimating the minimum stimulation frequency necessary to evoke tetanic progression based on muscle twitch parameters , 2017, Physiological measurement.

[78]  Qing He,et al.  Motion intent recognition of individual fingers based on mechanomyogram , 2017, Pattern Recognit. Lett..

[79]  Test-Retest Reliability and Reproducibility of Laser- versus Contact-Displacement Sensors in Mechanomyography: Implications for Musculoskeletal Research. , 2017, Journal of applied biomechanics.

[80]  Jing-Yi Guo,et al.  Dynamic monitoring of forearm muscles using one-dimensional sonomyography system. , 2008, Journal of rehabilitation research and development.

[81]  Edward D. Lemaire,et al.  Development of a wearable ultrasonic sensor and method for continuous monitoring of mechanical properties of plantar soft tissue for diabetic patients , 2014, 2014 IEEE International Ultrasonics Symposium.

[82]  L. Nazarian The top 10 reasons musculoskeletal sonography is an important complementary or alternative technique to MRI. , 2008, AJR. American journal of roentgenology.

[83]  Muscle thickness measurements to estimate gluteus medius and minimus activity levels. , 2014, Manual therapy.

[84]  Chen Chao,et al.  A flexible capacitive micromachined ultrasonic transducer (CMUT) array with increased effective capacitance from concave bottom electrodes for ultrasonic imaging applications , 2009, 2009 IEEE International Ultrasonics Symposium.

[85]  M. A. Islam,et al.  Mechanomyography Sensor Development, Related Signal Processing, and Applications: A Systematic Review , 2013, IEEE Sensors Journal.

[86]  Enzo Pasquale Scilingo,et al.  A Multimodal Transducer for Cardiopulmonary Activity Monitoring in Emergency , 2010, IEEE Transactions on Information Technology in Biomedicine.

[87]  Robert Rohling,et al.  Fabrication and testing of polymer-based capacitive micromachined ultrasound transducers for medical imaging , 2018, Microsystems & Nanoengineering.

[88]  Georgios I Papagiannis,et al.  Methodology of surface electromyography in gait analysis: review of the literature , 2019, Journal of medical engineering & technology.

[89]  Richard J. Schmidt,et al.  Comparing electromyographic and mechanomyographic frequency-based fatigue thresholds to critical torque during isometric forearm flexion , 2010, Journal of Neuroscience Methods.

[90]  V. Valencic,et al.  Evaluation of the ability to make non-invasive estimation of muscle contractile properties on the basis of the muscle belly response , 2006, Medical and Biological Engineering and Computing.

[91]  R J Baskin,et al.  Volume change and pressure development in muscle during contraction. , 1967, The American journal of physiology.

[92]  Yong-Ping Zheng,et al.  Human motion analysis with ultrasound and sonomyography , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[93]  A. Adler,et al.  An ultrasonic technique for imaging of tissue motion due to muscle contraction , 2009, 2009 IEEE International Ultrasonics Symposium.

[94]  E. Bäckman,et al.  Characteristics of tetanic muscle contraction in Parkinson patients , 1991, Acta neurologica Scandinavica.

[95]  Dominique Certon,et al.  Piezoelectric Transducer Design for Medical Diagnosis and NDE , 2008 .

[96]  L. Rusu,et al.  Tensiomyography method used for neuromuscular assessment of muscle training , 2013, Journal of NeuroEngineering and Rehabilitation.

[97]  Vojko Valencic,et al.  Spatial fiber type distribution in normal human muscle Histochemical and tensiomyographical evaluation. , 2005, Journal of biomechanics.

[98]  K. Grottel,et al.  The relationship between fusion index and stimulation frequency in tetani of motor units in rat medial gastrocnemius. , 1995, Archives italiennes de biologie.

[99]  E. Alentorn-Geli,et al.  Effects of anterior cruciate ligament injury on neuromuscular tensiomyographic characteristics of the lower extremity in competitive male soccer players , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[100]  M. Watakabe,et al.  Mechanical behaviour of condenser microphone in mechanomyography , 2001, Medical and Biological Engineering and Computing.

[101]  C. Orizio,et al.  Assessment of Skeletal Muscle Contractile Properties by Radial Displacement: The Case for Tensiomyography , 2018, Sports Medicine.

[102]  F. Esposito,et al.  Peripheral fatigue: new mechanistic insights from recent technologies , 2019, European Journal of Applied Physiology.

[103]  P. Bloomfield,et al.  PVDF transducers-a performance comparison of single-layer and multilayer structures , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[104]  Quantitative sonographic evaluation of muscle thickness and fasciculation prevalence in healthy subjects , 2019, Muscle & nerve.

[105]  Yongping Zheng,et al.  Reliability of sonomyography for pectoralis major thickness measurement. , 2010, Journal of manipulative and physiological therapeutics.

[106]  Tian-Ling Ren,et al.  A Flexible Ultrasound Transducer Array with Micro-Machined Bulk PZT , 2015, Sensors.

[107]  David Rodríguez-Ruiz,et al.  Effect of high-load and high-volume resistance exercise on the tensiomyographic twitch response of biceps brachii. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[108]  T. Beck,et al.  Linearity and reliability of the mechanomyographic amplitude versus dynamic constant external resistance relationships for the biceps brachii , 2010, Physiological measurement.

[109]  C. Than,et al.  The effects of accumulated muscle fatigue on the mechanomyographic waveform: implications for injury prediction , 2016, European Journal of Applied Physiology.

[110]  Tayla E. Kuehne,et al.  A comparison of acute changes in muscle thickness between A-mode and B-mode ultrasound , 2019, Physiological measurement.

[111]  Nicholas P. Fey,et al.  Lower Limb Motion Estimation Using Ultrasound Imaging: A Framework for Assistive Device Control , 2019, IEEE Journal of Biomedical and Health Informatics.

[112]  Honghai Liu,et al.  Towards Wearable A-Mode Ultrasound Sensing for Real-Time Finger Motion Recognition , 2018, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[113]  Qifa Zhou,et al.  Monitoring of the central blood pressure waveform via a conformal ultrasonic device , 2018, Nature Biomedical Engineering.

[114]  Guang-Quan Zhou,et al.  Measurement of Gender Differences of Gastrocnemius Muscle and Tendon Using Sonomyography during Calf Raises: A Pilot Study , 2017, BioMed research international.

[115]  B. Sañudo,et al.  Effectiveness of low-frequency vibration recovery method on blood lactate removal, muscle contractile properties and on time to exhaustion during cycling at VO2max power output , 2011, European Journal of Applied Physiology.