Pre-clinical validation of joint prostheses: a systematic approach.

The pre-clinical validation of new joint prostheses is an important step in the development process of a new implant design. The high success rate of modern prostheses makes it very difficult to ensure that new designs will exhibit significant improvements combined with a risk of failure as low as that of the designs currently in use. This situation requires a systematic re-thinking of the pre-clinical validation protocols. We advocate that a careful combination of risk analysis, experimental and numerical modelling, and the use of statistical finite element analysis to generalize the results to a simulated population, can provide the level of confidence required by class 3 devices as the joint prostheses recently became. The proposed approach is illustrated using the validation of a cemented epiphyseal stem as an example.

[1]  William R Taylor,et al.  Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. , 2007, Clinical biomechanics.

[2]  H. Malchau,et al.  Is the Harris Hip Score System Useful to Study the Outcome of Total Hip Replacement? , 2001, Clinical orthopaedics and related research.

[3]  C. Sorbie Arthroplasty in the treatment of subcapital hip fracture. , 2003, Orthopedics.

[4]  Bourne Rb,et al.  The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An in vitro study. , 1986 .

[5]  Marco Viceconti,et al.  Development and validation of a technique for strain measurement inside polymethyl methacrylate , 2000 .

[6]  Panayiotis Papadopoulos,et al.  The modified super-ellipsoid yield criterion for human trabecular bone. , 2004, Journal of biomechanical engineering.

[7]  R. Bourne,et al.  The Influence of Tibial Component Intramedullary Stems and Implant‐Cortex Contact on the Strain Distribution of the Proximal Tibia Following Total Knee Arthroplasty: An In Vitro Study , 1986, Clinical orthopaedics and related research.

[8]  Marco Viceconti,et al.  Subject-specific finite element models can accurately predict strain levels in long bones. , 2007, Journal of biomechanics.

[9]  M. Viceconti,et al.  Fretting wear in a modular neck hip prosthesis. , 1997, Journal of biomedical materials research.

[10]  S. Molloy,et al.  Health outcome measures in the evaluation of total hip arthroplasties--a comparison between the Harris hip score and the Oxford hip score. , 2005, The Journal of arthroplasty.

[11]  P Herberts,et al.  Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases , 2000, Acta orthopaedica Scandinavica.

[12]  J. Lewis,et al.  A crack model of a bone cement interface. , 1984, Journal of biomechanical engineering.

[13]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[14]  G. Bergmann,et al.  Hip joint contact forces during stumbling , 2004, Langenbeck's Archives of Surgery.

[15]  H Brenner,et al.  International variation in hip replacement rates , 2003, Annals of the rheumatic diseases.

[16]  B. Espehaug,et al.  The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties , 2000, Acta orthopaedica Scandinavica.

[17]  R. Huiskes,et al.  Failed innovation in total hip replacement. Diagnosis and proposals for a cure. , 1993, Acta orthopaedica Scandinavica.

[18]  S. Stea,et al.  Factors affecting aseptic loosening of 4750 total hip arthroplasties: multivariate survival analysis , 2007, BMC musculoskeletal disorders.

[19]  M. Viceconti,et al.  The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. , 2007, Medical engineering & physics.

[20]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[21]  P. Walker,et al.  Forces and moments telemetered from two distal femoral replacements during various activities. , 2001, Journal of biomechanics.

[22]  M. Viceconti,et al.  Design-related fretting wear in modular neck hip prosthesis. , 1996, Journal of biomedical materials research.

[23]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[24]  Angelo Cappello,et al.  Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between "good" and "bad" designs. , 2003, Journal of biomechanics.

[25]  D. Howie,et al.  Aging performance of a compliant layer bearing acetabular prosthesis in an ovine hip arthroplasty model. , 2006, The Journal of arthroplasty.

[26]  Jan Schmitt,et al.  Femoral strain changes after total hip arthroplasty--patient-specific finite element analyses 12 years after operation. , 2005, Medical engineering & physics.

[27]  M Viceconti,et al.  Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads. , 2007, Clinical biomechanics.

[28]  G. Pluhar,et al.  Assessing the dog as a model for human total hip replacement. Analysis of 38 canine cemented femoral components retrieved at post-mortem. , 2005, The Journal of bone and joint surgery. British volume.

[29]  Marco Viceconti,et al.  Primary stability of an anatomical cementless hip stem: a statistical analysis. , 2006, Journal of biomechanics.

[30]  Christopher Townsend,et al.  A multiaxial force-sensing implantable tibial prosthesis. , 2006, Journal of biomechanics.

[31]  R. Woledge,et al.  The forces in the distal femur and the knee during walking and other activities measured by telemetry. , 1998, The Journal of arthroplasty.

[32]  L Cristofolini,et al.  Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods. , 2001, Journal of biomechanics.