7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging

In designing large-sized volume type phased array coils for human head imaging at ultrahigh fields, e.g., 7T, minimizing electromagnetic coupling among array elements is technically challenging. A new decoupling method based on induced current compensation or elimination (ICE) for a microstrip line planar array has recently been proposed. In this study, an eight-channel transmit/receive volume array with ICE-decoupled loop elements was built and investigated to demonstrate its feasibility and robustness for human head imaging at 7T. Isolation between adjacent loop elements was better than - 25 dB with a human head load. The worst-case of the isolation between all of the elements was about - 17.5 dB. All of the MRI experiments were performed on a 7T whole-body human MR scanner. Images of the phantom and human head were acquired and g-factor maps were measured and calculated to evaluate the performance of the coil array. Compared with the conventional capacitively decoupled array, the ICE-decoupled array demonstrated improved parallel imaging ability and had a higher SNR. The experimental results indicate that the transceiver array design with ICE decoupling technique might be a promising solution to designing high performance transmit/receive coil arrays for human head imaging at ultrahigh fields.

[1]  Robert Turner,et al.  Fast MRI coil analysis based on 3-D electromagnetic and RF circuit co-simulation. , 2009, Journal of magnetic resonance.

[2]  Daniel K Sodickson,et al.  Concentric coil arrays for parallel MRI , 2005, Magnetic resonance in medicine.

[3]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[4]  Bing Wu,et al.  Shielded Microstrip Array for 7T Human MR Imaging , 2010, IEEE Transactions on Medical Imaging.

[5]  Z. Xie,et al.  An 8-channel non-overlapped spinal cord array coil for 7T MR imaging , 2007 .

[6]  Nikolai I Avdievich,et al.  Transceiver-Phased Arrays for Human Brain Studies at 7 T , 2011, Applied magnetic resonance.

[7]  Bing Wu,et al.  Multi-Channel Microstrip Transceiver Arrays Using Harmonics for High Field MR Imaging in Humans , 2012, IEEE Transactions on Medical Imaging.

[8]  K. Uğurbil,et al.  Microstrip RF surface coil design for extremely high‐field MRI and spectroscopy , 2001, Magnetic resonance in medicine.

[9]  Xiaoliang Zhang,et al.  Design of an inductively decoupled microstrip array at 9.4 T. , 2006, Journal of magnetic resonance.

[10]  Xu Chu,et al.  Ultra‐low output impedance RF power amplifier for parallel excitation , 2009, Magnetic resonance in medicine.

[11]  Sharmila Majumdar,et al.  An eight‐channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T , 2007 .

[12]  Jing Yuan,et al.  Interconnecting L/C components for decoupling and its application to low‐field open MRI array , 2007 .

[13]  Robert Turner,et al.  Influence of the position of decoupling capacitors on RF transmit performance for a 7T MRI loop array , 2012 .

[14]  Ravi S Menon,et al.  Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T , 2005, Magnetic resonance in medicine.

[15]  Wei Chen,et al.  An inverted-microstrip resonator for human head proton MR imaging at 7 tesla , 2005, IEEE Transactions on Biomedical Engineering.

[16]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[17]  Yong Pang,et al.  Parallel traveling‐wave MRI: A feasibility study , 2012, Magnetic resonance in medicine.

[18]  Mohamed Ahmed Abou-Khousa,et al.  MAGNETIC WALLS FOR RF COIL ELEMENTS DECOUPLING , 2012 .

[19]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[20]  Bing Wu,et al.  7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling , 2010, IEEE Transactions on Biomedical Engineering.

[21]  Zang-Hee Cho,et al.  Evaluation of capacitive and transformer decoupling methods using in non-overlapped array at 7 . 0 T , 2012 .

[22]  U Klose,et al.  Mapping of the radio frequency magnetic field with a MR snapshot FLASH technique. , 1992, Medical physics.

[23]  Peter Andersen,et al.  9.4T human MRI: Preliminary results , 2006, Magnetic resonance in medicine.

[24]  Bing Wu,et al.  Capacitively decoupled tunable loop microstrip (TLM) array at 7 T. , 2007, Magnetic resonance imaging.

[25]  K. Uğurbil,et al.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.

[26]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[27]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[28]  Sharmila Majumdar,et al.  Flexible transceiver array for ultrahigh field human MR imaging , 2012, Magnetic resonance in medicine.

[29]  Daniel K. Sodickson,et al.  Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI , 2001, Magnetic Resonance Materials in Physics, Biology and Medicine.

[30]  D. Vigneron,et al.  ICE decoupling technique for RF coil array designs. , 2011, Medical physics.

[31]  Wei Chen,et al.  Higher‐order harmonic transmission‐line RF coil design for MR applications , 2005, Magnetic resonance in medicine.