Impacts of the shading-type building-integrated photovoltaic claddings on electricity generation and cooling load component through shaded windows

The shading-type building-integrated photovoltaic (BIPV) claddings can act as power generators as well as external shading devices of a building, which reduce the energy consumption of the building. However, there is little information about energy impacts of different tilt angles of the shading-type BIPV claddings. By considering the typical meteorological conditions of Hong Kong, the energy performance of the shading-type BIPV claddings, in terms of the electricity generation and the cooling load reduction, is analyzed in this paper. The optimum tilt angle of PV modules for maximum electricity generation is found to be 20° instead of local latitude. Combining electricity generation and cooling load reduction, it can be concluded that the optimum tilt angles for the first type of the shading-type BIPV claddings vary from 30° to 50°, while the optimum tilt angle for the second type is 0°.

[1]  Hongxing Yang,et al.  Thermal behavior of a novel type see-through glazing system with integrated PV cells , 2009 .

[2]  Francis W.H. Yik,et al.  Predicting air-conditioning energy consumption of a group of buildings using different heat rejection methods , 2001 .

[3]  Lin Lu,et al.  A Study on Simulations of the Power Output and Practical Models for Building Integrated Photovoltaic Systems , 2004 .

[4]  Jiro Ohno Examples of successful architectural integration of PV: Japan , 2004 .

[5]  Hongxing Yang,et al.  Study on thermal performance of semi-transparent building-integrated photovoltaic glazings , 2008 .

[6]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[7]  Seung-Ho Yoo,et al.  Efficiency characteristic of building integrated photovoltaics as a shading device , 2002 .

[8]  Deo Prasad,et al.  Examples of successful architectural integration of PV: Australia , 2004 .

[9]  Danny H.W. Li,et al.  Analysis of solar heat gain factors using sky clearness index and energy implications , 2001 .

[10]  J. Michalsky,et al.  Modeling daylight availability and irradiance components from direct and global irradiance , 1990 .

[11]  J. Benemann,et al.  Building-integrated PV modules , 2001 .

[12]  D. Loveday,et al.  Convective heat transfer coefficients at a plane surface on a full-scale building facade , 1996 .

[13]  Stefano Ubertini,et al.  Performance estimation and experimental measurements of a photovoltaic roof , 2003 .

[14]  J. I. Yellott,et al.  Solar heat gain factors on average days , 1980 .

[15]  D. G. Stephenson Equations for solar heat gain through windows , 1965 .

[16]  Ji Jie,et al.  Modeling of a novel Trombe wall with PV cells , 2007 .

[17]  Ingo B. Hagemann Examples of successful architectural integration of PV: Germany , 2004 .

[18]  Dennis L. Loveday,et al.  Equilibrium thermal characteristics of a building integrated photovoltaic tiled roof , 2009 .

[19]  S. Klein,et al.  A method of estimating monthly average solar radiation on shaded receivers , 1979 .

[20]  John Burnett,et al.  Simple approach to cooling load component calculation through PV walls , 2000 .