Independent modal resonant shunt for multimode vibration control of a truss-cored sandwich panel

To realize multimode vibration control of a truss-cored sandwich panel, an independent modal resonant shunt control method is proposed in this paper. In this method, each piezoelectric stack transducer is connected to a single resonant shunt which is tuned to control the vibration of a single mode, and the location of the transducer is optimized to get a maximal electromechanical coupling with this mode. It is found that the optimal values of the resistance and inductance can not be determined by using a single-mode model of the structure, and thus a practical optimization method is employed to optimize the resonant shunt, which is verified with numerical simulation. The result shows that this method can add significant damping ratio to the controlled modes, and the resonant shunt circuits of different modes have no effect on each other. Finally the control effect of resonant shunt is compared with viscoelastic damper. It is indicated that the parameters of the resonant shunt can be tuned to get better effect.

[1]  J. Hollkamp Multimodal Passive Vibration Suppression with Piezoelectric Materials and Resonant Shunts , 1994 .

[2]  J. Wang,et al.  Design and demonstration of a high authority shape morphing structure , 2004 .

[3]  A. Preumont,et al.  The damping of a truss structure with a piezoelectric transducer , 2008 .

[4]  Nesbitt W. Hagood,et al.  Damping of structural vibrations with piezoelectric materials and passive electrical networks , 1991 .

[5]  Xu Guo,et al.  Passive vibration control of truss-cored sandwich plate with planar Kagome truss as one face plane , 2011 .

[6]  M. Ruzzene,et al.  Broadband vibration control through periodic arrays of resonant shunts: experimental investigation on plates , 2009 .

[7]  Peter J. Torvik,et al.  Damping Additions for Plates Using Constrained Viscoelastic Layers , 1972 .

[8]  Shu-yau Wu,et al.  Method for multiple-mode shunt damping of structural vibration using a single PZT transducer , 1998, Smart Structures.

[9]  A. Preumont,et al.  Vibration damping with negative capacitance shunts: theory and experiment , 2008 .

[10]  V. Steffen,et al.  Multimodal vibration damping through piezoelectric patches and optimal resonant shunt circuits , 2006 .

[11]  Ping-Cheung Tse,et al.  Optimal configuration of a piezoelectric patch for vibration control of isotropic rectangular plates , 2001 .

[12]  S. O. Reza Moheimani,et al.  Piezoelectric Transducers for Vibration Control and Damping , 2006 .

[13]  Andrew J. Fleming,et al.  Multiple mode current flowing passive piezoelectric shunt controller , 2003 .

[14]  P. Hughes,et al.  Modeling of linear viscoelastic space structures , 1993 .

[15]  Daniel J. Inman,et al.  Application of a Negative Capacitance Circuit in Synchronized Switch Damping Techniques for Vibration Suppression , 2011 .

[16]  Francesco dell’Isola,et al.  A revival of electric analogs for vibrating mechanical systems aimed to their efficient control by PZT actuators , 2002 .

[17]  Marcelo A. Trindade,et al.  Multimodal passive vibration control of sandwich beams with shunted shear piezoelectric materials , 2008 .

[18]  O. Thomas,et al.  Performance of piezoelectric shunts for vibration reduction , 2011 .

[19]  Jun Jiang,et al.  Optimization of actuator placement in a truss-cored sandwich plate with independent modal space control , 2011 .