Assessing Corrosion Damage in Posttensioned Concrete Structures Using Acoustic Emission

AbstractThe ingress of chlorides into posttensioned (PT) concrete structures is a leading cause of corrosion of the prestressing strands. This reduces the strength, durability, and service life of the structure and may result in catastrophic failure. A structural health monitoring (SHM) method is needed to improve the maintenance procedures associated with this method of construction. To evaluate the potential of acoustic emission monitoring for this application, long term corrosion monitoring tests were performed on specimens that were representative of internal and external posttensioning methods. Corrosion was induced in the specimens by adding chlorides to the grout and by performing wet/dry cycling with NaCl solution. The corrosion process was monitored by half-cell potential measurements (HCP) and acoustic emission (AE). Results show that AE has the ability to detect corrosion damage in the PT specimens with similar accuracy to HCP measurements. Furthermore, intensity analysis of the AE data shows t...

[1]  Masayasu Ohtsu,et al.  Detection and evaluation of failures in high-strength tendon of prestressed concrete bridges by acoustic emission , 2007 .

[2]  P. Ziehl,et al.  Acoustic-Emission-Based Characterization of Corrosion Damage in Cracked Concrete with Prestressing Strand , 2013 .

[3]  Ehsan Dehghan Niri,et al.  Corrosion monitoring of post‐tensioned concrete structures using fractal analysis of guided ultrasonic waves , 2014 .

[4]  Timothy J. Dickson,et al.  CORROSION ASSESSMENT OF A 34-YEAR-OLD PRECAST POST-TENSIONED CONCRETE GIRDER , 1993 .

[5]  C. S. Cai,et al.  Acoustic emission monitoring of bridges: Review and case studies , 2010 .

[6]  J. Broomfield Corrosion of Steel in Concrete: Understanding, investigation and repair , 1996 .

[7]  Simon A. Austin,et al.  Influence of diurnal and seasonal temperature variations on the detection of corrosion in reinforced concrete by acoustic emission , 2005 .

[8]  Surendra P. Shah,et al.  Application of acoustic emission technique to detection of reinforcing steel corrosion in concrete , 1998 .

[9]  Fabio Matta,et al.  Corrosion Damage Quantification of Prestressing Strands Using Acoustic Emission , 2013 .

[10]  J Elliott,et al.  Continuous acoustic monitoring of grouted post-tensioned concrete bridges , 2001 .

[11]  Yu Zuo,et al.  Influence of stress on passive behaviour of steel bars in concrete pore solution , 2011 .

[12]  Salvatore Salamone,et al.  Use of Interwire Ultrasonic Leakage to Quantify Loss of Prestress in Multiwire Tendons , 2011 .

[13]  A. Limam,et al.  STUDY AND CHARACTERIZATION BY ACOUSTIC EMISSION AND ELECTROCHEMICAL MEASUREMENTS OF CONCRETE DETERIORATION CAUSED BY REINFORCEMENT STEEL CORROSION , 2003 .

[14]  M. Ohtsu,et al.  Phenomenological Model of Corrosion Process in Reinforced Concrete Identified by Acoustic Emission , 2007 .

[15]  Walter Podolny,et al.  CORROSION OF PRESTRESSING STEELS AND ITS MITIGATION , 1992 .

[16]  Masayasu Ohtsu,et al.  Crack classification in concrete based on acoustic emission , 2010 .

[17]  R. Melchers,et al.  Phenomenological Modeling of Reinforcement Corrosion in Marine Environments , 2006 .

[18]  Jun Ki Lee Evaluation of external post-tensioned tendons using vibration signatures , 2007 .

[19]  H. Idrissi,et al.  Detection and identification of concrete cracking during corrosion of reinforced concrete by acoustic emission coupled to the electrochemical techniques , 2005 .

[20]  Paul Ziehl Applications of acoustic emission evaluation for civil infrastructure , 2008, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[21]  Fabio Matta,et al.  Early Corrosion Detection in Prestressed Concrete Girders Using Acoustic Emission , 2014 .

[22]  Radhakrishna Pillai Gopalakrishnan Electrochemical characterization and time-variant structural reliability assessment of post-tensioned, segmental concrete bridges , 2009 .

[23]  Masayasu Ohtsu,et al.  AE monitoring of corrosion process in cyclic wet-dry test , 2010 .

[24]  H. Idrissi,et al.  Detection of stress corrosion cracking of high-strength steel used in prestressed concrete structures by acoustic emission technique , 2008 .