Validation of the Tracmor triaxial accelerometer system for walking.

PURPOSE Walking is likely to contribute substantially to nonexercise activity thermogenesis. The Tracmor triaxial accelerometer system (Maastricht, The Netherlands) is the most widely validated system for detecting body movement in free-living subjects. The aim of this study was to validate the Tracmor triaxial accelerometer system for estimating the energy expenditure of walking. METHODS Experiments were conducted in healthy subjects. First, baseline variability for Tracmor output was determined for subjects standing still. Second, Tracmor output was compared for walking on a treadmill and on level ground. Third, both Tracmor output and energy expenditure were compared for walking on a treadmill and walking on level ground. Finally, the effect of gradient on Tracmor output and energy expenditure was compared for subjects walking on a treadmill. RESULTS The data demonstrated excellent reproducibility for comparing Tracmor output for standing (CV < 2%). There were excellent log-linear relationships between velocity and Tracmor output walking on a treadmill (r = 0.998) and on level ground (r = 0.999). Tracmor output and the energy expenditure of walking were inseparable for the two modalities of walking. However, the variance in response was such that to reliably derive the relationship between Tracmor output and energy expenditure, separate regression equations are needed for each subject. Finally, the Tracmor accelerometer did not detect the increased energy expenditure of walking that occurs as gradient increases. CONCLUSION The Tracmor triaxial accelerometer provides reproducible and reliable data on the body motion associated with walking regardless of whether a subject walks on a treadmill or level ground. Tracmor units can be used to predict the energetic cost of walking provided that separate regression equations are derived for each subject to convert Tracmor output to energy expenditure.

[1]  R R Wing,et al.  Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure. , 1990, Medicine and science in sports and exercise.

[2]  B. Nigg,et al.  A kinematic comparison of overground and treadmill running. , 1995, Medicine and science in sports and exercise.

[3]  K. Westerterp,et al.  24 h energy expenditure during a standardized activity protocol in young and elderly men. , 1995, European journal of clinical nutrition.

[4]  A. Prentice,et al.  Residual effect of graded levels of exercise on metabolic rate. , 1990, European journal of clinical nutrition.

[5]  J. D. Janssen,et al.  Daily physical activity assessment: comparison between movement registration and doubly labeled water. , 1996, Journal of applied physiology.

[6]  E. Haymes,et al.  Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and stepping , 1997, British journal of sports medicine.

[7]  E. Haymes,et al.  Walking and running energy expenditure estimated by Caltrac and indirect calorimetry. , 1993, Medicine and science in sports and exercise.

[8]  C. de Graaf,et al.  Energy expenditure and physical activity in subjects consuming full- or reduced-fat products aspart of their normal diet , 1996, British Journal of Nutrition.

[9]  J. Levine,et al.  Role of nonexercise activity thermogenesis in resistance to fat gain in humans. , 1999, Science.

[10]  J. D. Janssen,et al.  Assessment of energy expenditure for physical activity using a triaxial accelerometer. , 1994, Medicine and science in sports and exercise.

[11]  RK Johnson,et al.  Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometer , 1998, International Journal of Obesity.