A Phase-Locked Loop algorithm for single-phase grid-connected systems with sub and interharmonics immunity

This paper proposes a new closed-loop synchronization algorithm, PLL (Phase-Locked Loop), for applications in power conditioner systems for single-phase networks. The structure presented is based on the correlation of the input signal with a complex signal generated from the use of an adaptive filter in a PLL algorithm in order to minimize the computational effort. Moreover, the adapted PLL, due to the use of the adaptive filter, presents a higher level of rejection for two particular disturbances: interharmonic and subharmonic, when compared to the original algorithm. Simulation and experimental results will be presented in order to prove the efficacy of the proposed adaptive algorithm. The algorithm will be exposed to several scenarios. The response of the algorithm also be compared to the synchronization system based on SOGIFLL.

[1]  Felice Liccardo,et al.  Robust and Fast Three-Phase PLL Tracking System , 2011, IEEE Transactions on Industrial Electronics.

[2]  Dushan Boroyevich,et al.  Phase-Locked Loops using State Variable Feedback for Single-Phase Converter Systems , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[3]  Roberto Langella,et al.  On the Effects of Unbalances, Harmonics and Interharmonics on PLL Systems , 2013, IEEE Transactions on Instrumentation and Measurement.

[4]  Dushan Boroyevich,et al.  Phase-Locked Loop Noise Reduction via Phase Detector Implementation for Single-Phase Systems , 2011, IEEE Transactions on Industrial Electronics.

[5]  Hee-Je Kim,et al.  A Novel Grid Synchronization PLL Method Based on Adaptive Low-Pass Notch Filter for Grid-Connected PCS , 2014, IEEE Transactions on Industrial Electronics.

[6]  D. Sundararajan,et al.  Estimation of harmonics and interharmonics using phase-locked loop , 2013, 2013 International Conference on Power, Energy and Control (ICPEC).

[7]  Feng Zhou,et al.  Research on distributed power generation measurement technology , 2014, 2014 IEEE Workshop on Electronics, Computer and Applications.

[8]  Sami Väliviita Zero-crossing detection of distorted line voltages using 1-b measurements , 1999, IEEE Trans. Ind. Electron..

[9]  S. Saadate,et al.  A new topology for a modular active power filter , 2005, Proceedings of the IEEE International Symposium on Industrial Electronics, 2005. ISIE 2005..

[10]  A. Testa,et al.  On the effects of interharmonic distortion on static converters controlled by means of PLL systems , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[11]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[12]  Yuhong Wang,et al.  Enhanced Single Phase Locked Loop for Grid-Connected Converter in Distribution Network , 2010, 2010 International Conference on Electrical and Control Engineering.

[13]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[14]  Houshang Karimi,et al.  A magnitude/phase-locked loop system based on estimation of frequency and in-phase/quadrature-phase amplitudes , 2004, IEEE Transactions on Industrial Electronics.