Phase-contrast CT: qualitative and quantitative evaluation of atherosclerotic carotid artery plaque.

PURPOSE To evaluate the potential of phase-contrast computed tomography (CT) for atherosclerotic plaque imaging in human carotid arteries in an experimental ex vivo study. MATERIALS AND METHODS The study was approved by the institutional review board, and informed consent was obtained from the patients' relatives. Seven postmortem human carotid artery specimens were imaged at a laboratory setup by using a conventional x-ray tube and grating interferometer. After histologic processing, phase-contrast imaging and histopathologic data were matched. Characteristics of the necrotic core (NC) covered by a fibrous cap (FC), intraplaque hemorrhage (IPH), and calcifications (CAs) were established, and sensitivity, specificity, and accuracy of phase-contrast CT for plaque detection and the potential for accurate quantification were assessed. The Cohen κ and Pearson correlation coefficient R were used to determine the agreement between phase-contrast imaging and histopathologic findings for plaque characterization and correlation of quantitative plaque measurements, respectively. A difference with a P value of less than .05 was considered significant. RESULTS Characteristic criteria were found in all analyzed plaque components. Applying these criteria, phase-contrast CT had a good sensitivity for the detection of the FC and NC, IPH, and CAs (all, >80%) and excellent specificity and accuracy (all, >90%), with good interreader agreement (κ ≥ 0.72, P < .0001). There were excellent correlations for quantitative measurements of FC, NC, and CAs between phase-contrast imaging and histopathologic findings (R ≥ 0.92). Interreader reproducibility was excellent, with an intraclass correlation coefficient of 0.98 or higher for all measurements. CONCLUSION The results of this study indicate that ex vivo phase-contrast CT can help identify and quantify atherosclerotic plaque components, with excellent correlation to histopathologic findings. Although not yet applicable in vivo, phase-contrast CT may become a valuable tool to monitor atherosclerotic disease process noninvasively.

[1]  Franz Pfeiffer,et al.  Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies. , 2013, Zeitschrift fur medizinische Physik.

[2]  Franz Pfeiffer,et al.  X-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model , 2013, PloS one.

[3]  Franz Pfeiffer,et al.  Quantitative X-ray phase-contrast computed tomography at 82 keV. , 2013, Optics express.

[4]  M. Anastasio,et al.  An initial evaluation of analyser-based phase-contrast X-ray imaging of carotid plaque microstructure. , 2013, The British journal of radiology.

[5]  Franz Pfeiffer,et al.  Experimental results from a preclinical X-ray phase-contrast CT scanner , 2012, Proceedings of the National Academy of Sciences.

[6]  D. Stutman,et al.  Glancing angle Talbot-Lau grating interferometers for phase contrast imaging at high x-ray energy. , 2012, Applied physics letters.

[7]  F. Pfeiffer,et al.  Trimodal low-dose X-ray tomography , 2012, Proceedings of the National Academy of Sciences.

[8]  Carlo Catalano,et al.  Imaging of the carotid artery. , 2012, Atherosclerosis.

[9]  Guang-Hong Chen,et al.  Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping. , 2011, Medical physics.

[10]  Franz Pfeiffer,et al.  Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography. , 2011, Medical physics.

[11]  Atsushi Momose,et al.  Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm. , 2011, Optics express.

[12]  Li Zhang,et al.  Low dose reconstruction algorithm for differential phase contrast imaging. , 2011, Journal of X-ray science and technology.

[13]  Paola Coan,et al.  In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs , 2010, Physics in medicine and biology.

[14]  Franz Pfeiffer,et al.  High-resolution tomographic imaging of a human cerebellum: comparison of absorption and grating-based phase contrast , 2010, Journal of The Royal Society Interface.

[15]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[16]  P. C. Diemoz,et al.  Absorption, refraction and scattering in analyzer-based imaging: comparison of different algorithms. , 2010, Optics express.

[17]  Franz Pfeiffer,et al.  X-ray phase radiography and tomography of soft tissue using grating interferometry. , 2008, European journal of radiology.

[18]  M. Wintermark,et al.  High-Resolution CT Imaging of Carotid Artery Atherosclerotic Plaques , 2008, American Journal of Neuroradiology.

[19]  O. Bunk,et al.  X-ray imaging with the PILATUS 100k detector. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[20]  Atsushi Momose,et al.  Atherosclerotic plaque imaging using phase-contrast X-ray computed tomography. , 2008, American journal of physiology. Heart and circulatory physiology.

[21]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[22]  A Bravin,et al.  High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography , 2007, Physics in medicine and biology.

[23]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[24]  Udo Hoffmann,et al.  Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS. , 2007, Atherosclerosis.

[25]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[26]  A. Momose Recent Advances in X-ray Phase Imaging , 2005 .

[27]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[28]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[29]  H. C. Stary,et al.  Natural history and histological classification of atherosclerotic lesions: an update. , 2000, Arteriosclerosis, thrombosis, and vascular biology.

[30]  P Cloetens,et al.  A synchrotron radiation microtomography system for the analysis of trabecular bone samples. , 1999, Medical physics.

[31]  F Busch,et al.  X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. , 1997, Journal of computer assisted tomography.

[32]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[33]  Atsushi Momose,et al.  Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.

[34]  W D Wagner,et al.  A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. , 1995, Arteriosclerosis, thrombosis, and vascular biology.

[35]  Gao,et al.  X-ray image contrast from a simple phase object. , 1995, Physical review letters.