Phase measurement accuracy in digital holographic microscopy using a wavelength-stabilized laser diode

This work describes the influence of coherent illumination on phase measurement accuracy in digital holographic microscopy (DHM). To improve net phase accuracy in a DHM system, the phase referencing and temporal averaging techniques are applied simultaneously to suppress the phase noises caused by the laser source and image sensor. A comparison between a laser diode operated in single- and multi-modes is given to demonstrate the coherence effect on the fringe visibility and the reconstructed phase accuracy of digital holograms. Axial sub-nanometer accuracy in DHM with the fewest successive hologram recordings is performed using a wavelength-stabilized laser diode in single-mode operation.

[1]  B. Gutmann,et al.  Phase-shifter calibration and error detection in phase-shifting applications: a new method. , 1998, Applied optics.

[2]  N Streibl,et al.  Accuracy of phase shifting interferometry. , 1988, Applied optics.

[3]  A. Barty,et al.  Quantitative phase‐amplitude microscopy. III. The effects of noise , 2004, Journal of microscopy.

[4]  E. Cuche,et al.  Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy. , 2005, Optics letters.

[5]  O Monnom,et al.  Improvement in visibility of an in-focus reconstructed image in digital holography by reduction of the influence of out-of-focus objects. , 2005, Applied optics.

[6]  Etienne Cuche,et al.  Shot-noise influence on the reconstructed phase image signal-to-noise ratio in digital holographic microscopy. , 2006, Applied optics.

[7]  E. Cuche,et al.  Measurement of the integral refractive index and dynamic cell morphometry of living cells with digital holographic microscopy. , 2005, Optics express.

[8]  K. Yukimatsu,et al.  Phase-noise and shot-noise limited operations of low coherence optical time domain reflectometry , 1991 .

[9]  Chau-Jern Cheng,et al.  Determining the refractive index profile of micro-optical elements using transflective digital holographic microscopy , 2010 .

[10]  Tomasz Kozacki,et al.  Reconstruction of refractive-index distribution in off-axis digital holography optical diffraction tomographic system. , 2009, Optics express.

[11]  Wenhai Liu,et al.  Volume Holographic Grating Wavelength Stabilized Laser Diodes , 2007, IEEE Journal of Selected Topics in Quantum Electronics.

[12]  E. Cuche,et al.  Axial sub-nanometer accuracy in digital holographic microscopy , 2008 .

[13]  T. Poon Digital Holography and Three-Dimensional Display , 2006 .

[14]  Patrik Langehanenberg,et al.  Phase noise optimization in temporal phase-shifting digital holography with partial coherence light sources and its application in quantitative cell imaging. , 2009, Applied optics.

[15]  Ting-Chung Poon,et al.  Optical sectioning with a low-coherence phase-shifting digital holographic microscope. , 2011, Applied optics.

[16]  Christian Depeursinge,et al.  Influence of shot noise on phase measurement accuracy in digital holographic microscopy. , 2007, Optics express.

[17]  Zeev Zalevsky,et al.  Synthetic aperture superresolution with multiple off-axis holograms. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  Christian Depeursinge,et al.  Total aberrations compensation in digital holographic microscopy with a reference conjugated hologram. , 2006, Optics express.