Suppression of saturation artifacts in swept source optical coherence tomography using dual channel detection

A technique to suppress saturation artifacts in swept source optical coherence tomography (SSOCT) system was presented. The detected signal was split into two channels of a high speed data acquisition card with two levels by a power divider. The signal in one channel with higher level was used to reconstruct OCT images and the signal in the other channel with lower level was used to compensate the saturated signal in the first channel by calibrating the splitting ratio between the two channels. Based on dual channel detection, this technique can enhance the dynamic range of SSOCT system and remove saturation artifacts in OCT imaging with simple and cost effective design. Imaging of human finger with the system demonstrated that this method can achieve high dynamic range without saturation artifacts in SSOCT.

[1]  Jin U. Kang,et al.  Real-time reference A-line subtraction and saturation artifact removal using graphics processing unit for high-frame-rate Fourier-domain optical coherence tomography video imaging , 2012 .

[2]  J. Kim,et al.  Adaptive optimization of reference intensity for optical coherence imaging using galvanometric mirror tilting method , 2015 .

[3]  Bin Liu,et al.  Improvement in dynamic range limitation of swept source optical coherence tomography by true logarithmic amplification. , 2010, Journal of the Optical Society of America. A, Optics, image science, and vision.

[4]  Wen-Chuan Kuo,et al.  Balanced detection for spectral domain optical coherence tomography. , 2013, Optics express.

[5]  Peter Andretzky,et al.  Optical coherence tomography by spectral radar: dynamic range estimation and in-vivo measurements of skin , 1999, European Conference on Biomedical Optics.

[6]  Marinko Sarunic,et al.  Detailed visualization of the anterior segment using fourier-domain optical coherence tomography. , 2008, Archives of ophthalmology.

[7]  Wolfgang Wieser,et al.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. , 2010, Optics express.

[8]  Freddy T. Nguyen,et al.  Optical coherence tomography: a review of clinical development from bench to bedside. , 2007, Journal of biomedical optics.

[9]  Chiung-Ting Wu,et al.  Two-Level Optical Coherence Tomography Scheme for Suppressing Spectral Saturation Artifacts , 2014, Sensors.

[10]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[11]  A. Rollins,et al.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. , 2009, JACC. Cardiovascular interventions.

[12]  Sucbei Moon,et al.  Reference spectrum extraction and fixed-pattern noise removal in optical coherence tomography , 2010, Optics express.