Proton therapy dosimetry using the scintillation of the silica fibers.

We investigate the feasibility of proton therapy dose measurement by using scintillation of a bare silica glass fiber. The emission spectra of the optical fiber at various depths in tissue-mimicking phantoms, irradiated with proton beams of energies 100-225 MeV show two distinct peaks at 460 and 650 nm whose nature is connected with the silica point defects. Our experimental results and Monte Carlo simulation showed that the Čerenkov radiation cannot be responsible for such a phenomenon. We showed that the intensity of the peak at 650 nm correlates with the proton dose with a minimal effect of ionization quenching, while the intensity peak at 460 nm under-reports the radiation dose.

[1]  Wook Jae Yoo,et al.  Fiber-optic Cerenkov radiation sensor for proton therapy dosimetry. , 2012, Optics express.

[2]  Scott C Davis,et al.  Time-gated Cherenkov emission spectroscopy from linear accelerator irradiation of tissue phantoms. , 2012, Optics letters.

[3]  Robert Speller,et al.  Imaging Cerenkov emission as a quality assurance tool in electron radiotherapy , 2014, Physics in medicine and biology.

[4]  Timothy C. Zhu,et al.  Phosphor-based fiber optic microprobes for ionizing beam radiation dosimetry , 2015, Photonics West - Biomedical Optics.

[5]  Scott C Davis,et al.  Čerenkov excited fluorescence tomography using external beam radiation. , 2013, Optics letters.

[6]  Wook Jae Yoo,et al.  Feasibility of fiber-optic radiation sensor using Cerenkov effect for detecting thermal neutrons. , 2013, Optics express.

[7]  B. Pogue,et al.  Light sheet luminescence imaging with Cherenkov excitation in thick scattering media. , 2016, Optics letters.

[8]  Jarod C Finlay,et al.  Spectroscopic separation of Čerenkov radiation in high-resolution radiation fiber dosimeters , 2015, Journal of biomedical optics.

[9]  R. Kudchadker,et al.  Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer , 2014, Physics in medicine and biology.

[10]  Marco Cannas,et al.  Luminescence of the surface nonbridging oxygen hole center in silica : Spectral and decay properties , 2008 .

[11]  Scott C Davis,et al.  Three-dimensional Čerenkov tomography of energy deposition from ionizing radiation beams. , 2013, Optics letters.

[12]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[13]  Brian W Pogue,et al.  Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose , 2014, Physics in medicine and biology.

[14]  Stavros G. Demos,et al.  Optical defects produced in fused silica during laser-induced breakdown , 2003 .

[15]  Brian W Pogue,et al.  Review of biomedical Čerenkov luminescence imaging applications. , 2015, Biomedical optics express.

[16]  Jarod C Finlay,et al.  The visible signal responsible for proton therapy dosimetry using bare optical fibers is not Čerenkov radiation. , 2016, Medical physics.

[17]  Arash Darafsheh,et al.  Characterization of rare-earth-doped nanophosphors for photodynamic therapy excited by clinical ionizing radiation beams , 2015, Photonics West - Biomedical Optics.

[18]  Arash Darafsheh,et al.  Fiber optic microprobes with rare-earth-based phosphor tips for proton beam characterization , 2016, SPIE BiOS.

[19]  Brian W. Pogue,et al.  Separation of Čerenkov radiation in irradiated optical fibers by optical spectroscopy , 2015, Photonics West - Biomedical Optics.

[20]  Wayne D Newhauser,et al.  The physics of proton therapy , 2015, Physics in medicine and biology.

[21]  Luc Beaulieu,et al.  Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy , 2016, Physics in medicine and biology.

[22]  Scott C Davis,et al.  Video-rate optical dosimetry and dynamic visualization of IMRT and VMAT treatment plans in water using Cherenkov radiation. , 2014, Medical physics.

[23]  L. Beaulieu,et al.  On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry , 2013, Physics in medicine and biology.

[24]  Timothy C. Zhu,et al.  Fiber optic probes based on silver-only coated hollow glass waveguides for ionizing beam radiation dosimetry , 2016, SPIE BiOS.