Remote sensing of CO2 and CH4 using solar absorption spectrometry with a low resolution spectrometer

Abstract. Throughout the last few years solar absorption Fourier Transform Spectrometry (FTS) has been further developed to measure the total columns of CO2 and CH4. The observations are performed at high spectral resolution, typically at 0.02 cm−1. The precision currently achieved is generally better than 0.25%. However, these high resolution instruments are quite large and need a dedicated room or container for installation. We performed these observations using a smaller commercial interferometer at its maximum possible resolution of 0.11 cm−1. The measurements have been performed at Bremen and have been compared to observations using our high resolution instrument also situated at the same location. The high resolution instrument has been successfully operated as part of the Total Carbon Column Observing Network (TCCON). The precision of the low resolution instrument is 0.32% for XCO2 and 0.46% for XCH4. A comparison of the measurements of both instruments yields an average deviation in the retrieved daily means of l0.2% for CO2. For CH4 an average bias between the instruments of 0.47% was observed. For test cases, spectra recorded by the high resolution instrument have been truncated to the resolution of 0.11 cm−1. This study gives an offset of 0.03% for CO2 and 0.26% for CH4. These results indicate that for CH4 more than 50% of the difference between the instruments results from the resolution dependent retrieval. We tentatively assign the offset to an incorrect a-priori concentration profile or the effect of interfering gases, which may not be treated correctly.

[1]  James B. Abshire,et al.  Calibration of the Total Carbon Column Observing Network using aircraft profile data , 2010 .

[2]  Justus Notholt,et al.  Seasonal and latitudinal variations of column averaged volume‐mixing ratios of atmospheric CO2 , 2005 .

[3]  Geoffrey C. Toon,et al.  Tropospheric methane retrieved from ground‐based near‐IR solar absorption spectra , 2003 .

[4]  Justus Notholt,et al.  Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites , 2011 .

[5]  G. Toon,et al.  Atmospheric CO2 retrieved from ground‐based near IR solar spectra , 2002 .

[6]  T. Blumenstock,et al.  Analysis of the instrumental line shape of high-resolution fourier transform IR spectrometers with gas cell measurements and new retrieval software. , 1999, Applied optics.

[7]  Gretchen Keppel-Aleks,et al.  Reducing the impact of source brightness fluctuations on spectra obtained by Fourier-transform spectrometry. , 2007, Applied optics.

[8]  G. Toon,et al.  Carbon dioxide column abundances at the Wisconsin Tall Tower site , 2006 .

[9]  Peter Bergamaschi,et al.  First ground-based FTIR observations of methane in the inner tropics over several years , 2010 .

[10]  C. Rinsland,et al.  ATMOS data processing and science analysis methods. , 1991, Applied optics.

[11]  C. B. Farmer,et al.  Composition measurements of the 1989 Arctic winter stratosphere by airborne infrared solar absorption spectroscopy , 1992 .

[12]  R. Lindenmaier,et al.  B355 The Total Carbon Column Observing Network (TCCON) , 2011 .

[13]  D. Wunch,et al.  Total column CO 2 measurements at Darwin, Australia – site description and calibration against in situ aircraft profiles , 2010 .

[14]  Justus Notholt,et al.  Side by side measurements of CO2 by ground-based Fourier transform spectrometry (FTS) , 2010 .

[15]  Justus Notholt,et al.  The Total Carbon Column Observing Network , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[16]  J. Randerson,et al.  New constraints on Northern Hemisphere growing season net flux , 2007 .