Implementation of GPU-accelerated back projection for EPR imaging.

Electron paramagnetic resonance (EPR) Imaging (EPRI) is a robust method for measuring in vivo oxygen concentration (pO2). For 3D pulse EPRI, a commonly used reconstruction algorithm is the filtered backprojection (FBP) algorithm, in which the backprojection process is computationally intensive and may be time consuming when implemented on a CPU. A multistage implementation of the backprojection can be used for acceleration, however it is not flexible (requires equal linear angle projection distribution) and may still be time consuming. In this work, single-stage backprojection is implemented on a GPU (Graphics Processing Units) having 1152 cores to accelerate the process. The GPU implementation results in acceleration by over a factor of 200 overall and by over a factor of 3500 if only the computing time is considered. Some important experiences regarding the implementation of GPU-accelerated backprojection for EPRI are summarized. The resulting accelerated image reconstruction is useful for real-time image reconstruction monitoring and other time sensitive applications.

[1]  Wen-mei W. Hwu,et al.  Optimization principles and application performance evaluation of a multithreaded GPU using CUDA , 2008, PPoPP.

[2]  Rizwan Ahmad,et al.  Enhanced resolution for EPR imaging by two-step deblurring. , 2007, Journal of magnetic resonance.

[3]  Lei Xing,et al.  GPU computing in medical physics: a review. , 2011, Medical physics.

[4]  Howard J Halpern,et al.  Electron paramagnetic resonance oxygen imaging of a rabbit tumor using localized spin probe delivery. , 2010, Medical physics.

[5]  Howard J Halpern,et al.  Principal component analysis enhances SNR for dynamic electron paramagnetic resonance oxygen imaging of cycling hypoxia in vivo , 2014, Magnetic resonance in medicine.

[6]  Jens Frahm,et al.  Real‐time MRI at a resolution of 20 ms , 2010, NMR in biomedicine.

[7]  Howard J. Halpern,et al.  Imaging radio frequency electron‐spin‐resonance spectrometer with high resolution and sensitivity for in vivo measurements , 1989 .

[8]  Colin Mailer,et al.  Comparison of 250 MHz electron spin echo and continuous wave oxygen EPR imaging methods for in vivo applications. , 2011, Medical physics.

[9]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[10]  Howard J Halpern,et al.  Comparison of local and global angular interpolation applied to spectral-spatial EPR image reconstruction. , 2007, Medical physics.

[11]  Shuo Zhang,et al.  Nonlinear inverse reconstruction for real‐time MRI of the human heart using undersampled radial FLASH , 2010, Magnetic resonance in medicine.

[12]  Howard J Halpern,et al.  Spatially uniform sampling in 4-D EPR spectral-spatial imaging. , 2007, Journal of magnetic resonance.

[13]  Howard J Halpern,et al.  Object dependent sweep width reduction with spectral-spatial EPR imaging. , 2007, Journal of magnetic resonance.

[14]  Rizwan Ahmad,et al.  EPR oximetry in three spatial dimensions using sparse spin distribution. , 2008, Journal of magnetic resonance (San Diego, Calif. 1997 : Print).

[15]  David Atkinson,et al.  Real-Time Reconstruction of Sensitivity Encoded Radial Magnetic Resonance Imaging Using a Graphics Processing Unit , 2009, IEEE Transactions on Medical Imaging.

[16]  Rizwan Ahmad,et al.  A parametric approach to spectral-spatial EPR imaging. , 2007, Journal of magnetic resonance.

[17]  Howard J Halpern,et al.  Simulation of 4D spectral-spatial EPR images. , 2007, Journal of magnetic resonance.