Investigation of flow parameters and efficiency of mixture separation on a structured packing

Results of experimental study of the effect of initial maldistribution of structured packing irrigation on efficiency of binary mixture separation are presented in this article. The studies were carried out in the experimental distillation column with the diameter of 0.9 m using the R114 and R21 freon mixture. Experiments were performed on the structured Mellapak 350.Y packing of stainless steel 316L, containing 19 layers with the total height of 4.016 m at the ratio of mole liquid and vapor flow rates L/V = 1 and 1.7, respectively, and the pressure in the upper part of the column ptop = 3 bars. Nonuniformity at the packing inlet was generated via the blocking of some holes in the liquid distributor. Here, we present some results on efficiency of mixture separation, pressure drop on the packing, distribution of local liquid flow rate under the packing over the cross-section and on the column wall within the range of vapor loading factor (0.69 < Fv < 1.61 Pa0.5), as well as experimental data on distribution of local concentration of the low-boiling component over the cross-section and along the height of the structured packing. It is found out that significant maldistribution of mixture concentration and liquid flow rate over the cross-section slightly changes along the height in the lower part of the column at a change in the degree of packing irrigation nonuniformity at the inlet. It is shown that efficiency of mixture separation depends considerably on the value of parameter L/V, vapor flow factor Fv, and size of the zone underirrigated by liquid at the inlet. In the studied range of liquid and vapor flow rates, the relative pressure drop on the packing does not depend on the ratio of liquid and vapor flow rates L/V and degree of irrigation maldistribution. © 2013 American Institute of Chemical Engineers AIChE J 60: 690–705, 2014

[1]  F. J. Zuiderweg,et al.  Small scale and large scale liquid maldistribution in packed columns , 1986 .

[2]  Chau-Chyun Chen,et al.  New mass-transfer correlations for packed towers , 2012 .

[3]  D. Gunn,et al.  Liquid distribution in packed columns , 1993 .

[4]  Ž. Olujić,et al.  Structured packing efficiency—Vital information for the chemical industry , 2011 .

[5]  A. Pavlenko,et al.  Hydrodynamics in Falling Liquid Films on Surfaces with Complex Geometry , 2009 .

[6]  D. M. Markovich,et al.  Experimental Investigation of Liquid Distribution Over Structured Packing , 2008 .

[7]  M. Kraume,et al.  Liquid film flow on structured wires: Fluid dynamics and gas‐side mass transfer , 2013 .

[8]  Z. Olujic,et al.  Experimental Studies on the Interaction Between the Initial Liquid Distribution and the Performance of Structured Packings , 1990 .

[9]  O. Matar,et al.  Modelling hydrodynamics and mass transfer in structured packings , 2002 .

[10]  Z. Olujic,et al.  Liquid distribution images on structured packing by X‐ray computed tomography , 2001 .

[11]  Houghton,et al.  Experimental study of the effect of maldistribution at the structured packing inlet on the freon mixture separation efficiency , 2009 .

[12]  A. Pavlenko,et al.  Separation of mixtures and distribution of a liquid on a structured packing in a large-scale model of a distillation column , 2006 .

[13]  A. Pavlenko,et al.  Development of mixture composition maldistribution in a distillation column with structured packing , 2010 .

[14]  Milorad P. Dudukovic,et al.  Countercurrent flow distribution in structured packing via computed tomography , 2005 .

[15]  Christophe Boyer,et al.  Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system , 2002 .