Quantitative determination of sulfur-containing anions in complex matrices with capillary electrophoresis and conductivity detection.

The analysis of sulfur species in complex matrices, like environmentally related samples, requires selective and sensitive as well as robust determination methods. As many as possible different anions need to be quantified in a reasonable analysis time. Besides ion chromatography, capillary electrophoresis has proven to be a very efficient technique for the separation and determination of ionic compounds. With the advantages of less sample and solvent consumption compared to conventional LC, short separation time, inexpensive and robust capillaries, CE was used to separate the anions sulfate, sulfite, thiosulfate, thiocyanate and sulfide. Detection and injection modes and the composition of the separation buffers have been varied to find the most suitable conditions. Conductivity detection after electrokinetic sample injection and improvement of calibration linearity allowed the determination of sulfur containing anions with low limits of detection (8 to 50 micrograms/l). The developed CE method was applied to the analysis of water from an open-pit mining lake.

[1]  W. Salomons,et al.  Biogeodynamics of Pollutants in Soils and Sediments , 1995 .

[2]  Ring-Ling Chien,et al.  Field amplified sample injection in high-performance capillary electrophoresis , 1991 .

[3]  A. Zemann,et al.  Determination of phenols, inorganic anions, and carboxylic acids in kraft black liquors by capillary electrophoresis , 1998 .

[4]  A. Zemann,et al.  Determination of inorganic anions in Kraft pulping liquors by capillary electrophoresis , 1996 .

[5]  James P. Landers,et al.  Handbook of Capillary Electrophoresis , 1993 .

[6]  N. Danielson,et al.  Naphthalenesulfonates as Electrolytes for Capillary Electrophoresis of Inorganic Anions, Organic Acids, and Surfactants with Indirect Photometric Detection , 1994 .

[7]  S. Motellier,et al.  Sulfur speciation by capillary electrophoresis with indirect spectrophotometric detection: In search of a suitable carrier electrolyte to maximize sensitivity , 1997 .

[8]  Hossein. Salimi-Moosavi,et al.  Capillary electrophoresis of inorganic anions in nonaqueous media with electrochemical and indirect UV detection , 1995 .

[9]  R. Dick Sulphur Cycling on the Continents: Wetlands, Terrestrial Ecosystems, and Associated Water Bodies. 1992 , 1993 .

[10]  W R Jones,et al.  Quantitative Analysis of Anions at ppb/ppt Levels with Capillary Electrophoresis and Conductivity Detection:  Enhancement of System Linearity and Precision Using an Internal Standard. , 1998, Analytical chemistry.

[11]  W. R. Jones,et al.  Optimization of inorganic capillary electrophoresis for the analysis of anionic solutes in real samples , 1991 .

[12]  S. Valsecchi,et al.  Determination of anions in rainwater by capillary electrophoresis with conductivity detection , 1997 .

[13]  P. Boček,et al.  On‐line fiber optic UV detection cell and conductivity cell for capillary zone electrophoresis , 1986 .

[14]  C. Bjergegaard,et al.  Determination of thiocyanate, iodide, nitrate and nitrite in biological samples by micellar electrokinetic capillary chromatography , 1995 .

[15]  D. Burgi,et al.  Optimization in sample stacking for high-performance capillary electrophoresis , 1991 .

[16]  K. Bächmann,et al.  Analysis of single raindrops in the nl range by capillary electrophoresis , 1996 .

[17]  W. Buchberger,et al.  Effects of carrier electrolyte composition on separation selectivity in capillary zone electrophoresis of low-molecular-mass anions , 1992 .

[18]  Christopher A. Pohl,et al.  Cross-Linked Polymer Coatings for Capillary Electrophoresis and Application to Analysis of Basic Proteins, Acidic Proteins, and Inorganic Ions , 1997 .