Towards source volume estimation of interictal spikes in focal epilepsy using magnetoencephalography

Interictal spikes are a hallmark of cortical epileptogenicity; their spatial distribution in the cortex defines the so-called 'irritative' zone or spiking volume (SV). Delineating the SV precisely is a challenge during the presurgical evaluation of patients with epilepsy. Magnetoencephalography (MEG) recordings enable determination of the brain sources of epileptic spikes using source localization procedures. Most previous clinical MEG studies have relied on dipole modeling of epileptic spikes, which does not permit a volumetric estimation of the spiking cortex. In the present study, we propose a new source modeling procedure, Volumetric Imaging of Epileptic Spikes (VIES). In VIES, the SV is identified as the 3D region where sources of the high frequency activities (>20 Hz) associated with epileptic spikes are distributed. We localized these sources using a beamforming approach (DICS, Dynamic Imaging of Coherent Neural Sources). To determine the optimal parameters and accuracy of the method, we compared the SV obtained by VIES with the SV defined by the invasive gold standard, intracranial stereotactic EEG recordings (SEEG), in 21 patients with focal epilepsy. Using rigorous validation criteria based on the exact anatomical location of SEEG contacts, we found that the overall sensitivity of VIES for detecting spiking SEEG contacts was 76% and its specificity for correctly identifying non-spiking SEEG contacts was 67%, indicating a good agreement between VIES and SEEG. Moreover, we found that classical dipole clustering was not informative in 9/21 patients, while VIES enable to delineate the SV in all patients. For the 12 patients having a SV delineated both with VIES and dipole clustering, VIES method had higher sensitivity and lower specificity. This proof-of-concept study shows that VIES is a promising approach to non-invasive estimation of the SV in focal epilepsy.

[1]  J. Pernier,et al.  Oscillatory γ-Band (30–70 Hz) Activity Induced by a Visual Search Task in Humans , 1997, The Journal of Neuroscience.

[2]  Kristen Riley,et al.  Magnetic source imaging versus intracranial electroencephalogram in epilepsy surgery: A prospective study , 2006, Annals of neurology.

[3]  M. Fuchs,et al.  Confidence limits of dipole source reconstruction results , 2004, Clinical Neurophysiology.

[4]  C H Ferrier,et al.  Interictal magnetoencephalography and the irritative zone in the electrocorticogram. , 2009, Brain : a journal of neurology.

[5]  Adam N Mamelak,et al.  Magnetoencephalography-directed surgery in patients with neocortical epilepsy. , 2002, Journal of neurosurgery.

[6]  J. -P. Vignal,et al.  Non-supervised spatio-temporal analysis of interictal magnetic spikes: comparison with intracerebral recordings , 2003, Clinical Neurophysiology.

[7]  J. Ebersole,et al.  Cortical Substrates of Scalp EEG Epileptiform Discharges , 2007, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[8]  Gabriela Scheler,et al.  Utilization of magnetoencephalography results to obtain favourable outcomes in epilepsy surgery. , 2004, Brain : a journal of neurology.

[9]  G. Barnes,et al.  Statistical flattening of MEG beamformer images , 2003, Human brain mapping.

[10]  Robert C. Knowlton,et al.  The role of FDG-PET, ictal SPECT, and MEG in the epilepsy surgery evaluation , 2006, Epilepsy & Behavior.

[11]  Gareth R. Barnes,et al.  Practical constraints on estimation of source extent with MEG beamformers , 2011, NeuroImage.

[12]  Ayako Ochi,et al.  Preoperative simulation of intracerebral epileptiform discharges: synthetic aperture magnetometry virtual sensor analysis of interictal magnetoencephalography data. , 2006, Journal of neurosurgery.

[13]  H. Lüders,et al.  Presurgical evaluation of epilepsy. , 2001, Brain : a journal of neurology.

[14]  Krish D. Singh,et al.  A new approach to neuroimaging with magnetoencephalography , 2005, Human brain mapping.

[15]  J Gross,et al.  REPRINTS , 1962, The Lancet.

[16]  Anto Bagic,et al.  American Clinical MEG Society (ACMEGS) position statement: the value of magnetoencephalography (MEG)/magnetic source imaging (MSI) in noninvasive presurgical evaluation of patients with medically intractable localization-related epilepsy. , 2009, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  J. Vrba,et al.  Signal processing in magnetoencephalography. , 2001, Methods.

[18]  Al Bartolucci,et al.  Functional imaging: II. Prediction of epilepsy surgery outcome , 2008, Annals of neurology.

[19]  Marc Guenot,et al.  Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method , 2002, Stereotactic and Functional Neurosurgery.

[20]  Jerome Engel,et al.  Surgical treatment of the epilepsies , 1993 .

[21]  M. Scherg,et al.  Noninvasive Source Localization of Interictal EEG Spikes: Effects of Signal-to-Noise Ratio and Averaging , 2006, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[22]  Al Bartolucci,et al.  Functional imaging: I. Relative predictive value of intracranial electroencephalography , 2008, Annals of neurology.

[23]  O. Bertrand,et al.  Oscillatory gamma-band (30-70 Hz) activity induced by a visual search task in humans. , 1997, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[24]  Srikantan S. Nagarajan,et al.  Fast oscillations associated with interictal spikes localize the epileptogenic zone in patients with partial epilepsy , 2008, NeuroImage.

[25]  M. Cook,et al.  EEG source localization in focal epilepsy: Where are we now? , 2008, Epilepsia.

[26]  Ayako Ochi,et al.  Spatially filtered magnetoencephalography compared with electrocorticography to identify intrinsically epileptogenic focal cortical dysplasia , 2008, Epilepsy Research.

[27]  F. E. Posthumus Meyjes,et al.  Recommendations for the practice of clinical neurophysiology Made by the international federation of societies for electroencephalography and clinical neurophysiology, xiii + 191 pages, illustrated, Elsevier Science Publishers, Amsterdam, New York, Oxford, 1983, US$ 9.95, Dfl 35.00 , 1984, Journal of the Neurological Sciences.

[28]  Gary G. R. Green,et al.  Source stability index: A novel beamforming based localisation metric , 2010, NeuroImage.

[29]  W W Sutherling,et al.  Influence of magnetic source imaging for planning intracranial EEG in epilepsy , 2008, Neurology.

[30]  J. Ebersole,et al.  Intracranial EEG Substrates of Scalp EEG Interictal Spikes , 2005, Epilepsia.

[31]  John S. Ebersole,et al.  Localizing value of scalp EEG spikes: A simultaneous scalp and intracranial study , 2007, Clinical Neurophysiology.

[32]  Geertjan Huiskamp,et al.  Interictal electromagnetic source imaging in focal epilepsy: practices, results and recommendations , 2008, Current opinion in neurology.

[33]  Hiroshi Masuda,et al.  Single and Multiple Clusters of Magnetoencephalographic Dipoles in Neocortical Epilepsy: Significance in Characterizing the Epileptogenic Zone , 2006, Epilepsia.

[34]  Thomas E. Nichols,et al.  Thresholding of Statistical Maps in Functional Neuroimaging Using the False Discovery Rate , 2002, NeuroImage.

[35]  G Scheler,et al.  Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases. , 2003, Brain : a journal of neurology.

[36]  Jerome Engel,et al.  Outcome with respect to epileptic seizures. , 1993 .

[37]  J Gotman,et al.  Dipole modeling of scalp electroencephalogram epileptic discharges: correlation with intracerebral fields , 2001, Clinical Neurophysiology.

[38]  J. Vrba Magnetoencephalography: the art of finding a needle in a haystack , 2002 .