Distortion effects on servo position error transfer function
暂无分享,去创建一个
Two kinds of nonlinear distortion of hard-disk-drive position error signal (PES) transfer function are examined and modeled. The first distortion is the saturation of the PES due to narrow read width. The second distortion is the on-track dead band at the center of the transfer function due to wide erase band. Several formulas are developed to describe the relationships between the distortion effects and the design parameters: read width, track spacing, and erase width. These distortions are highly undesirable for the track following sectored servo system. However, they are predictable and avoidable if certain conditions are satisfied. The geometrical analysis of the distortion phenomenon is presented here.
[1] P. K. George,et al. Effects of current and frequency on write, read, and erase widths for thin-film inductive and magnetoresistive heads , 1989 .
[2] David A. Thompson,et al. Outlook for maintaining areal density growth in magnetic recording , 1994 .
[3] J.K. Lee. A track density model for magnetoresistive heads considering the erase bands , 1990, International Conference on Magnetics.
[4] Marvin Camras,et al. Magnetic Recording Handbook , 1988 .