Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment

Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

[1]  F. Duck Physical properties of tissue , 1990 .

[2]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[3]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[4]  Masakatsu G. Fujie,et al.  Temperature dependence of thermal conductivity of liver based on various experiments and a numerical simulation for RF ablation , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[5]  John G. Webster,et al.  Finite-element analysis of hepatic multiple probe radio-frequency ablation , 2002, IEEE Transactions on Biomedical Engineering.

[6]  Masakatsu G. Fujie,et al.  Estimation of intraoperative blood flow during liver RF ablation using a finite element method-based biomechanical simulation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  P. Wolf,et al.  A Three-Dimensional Finite Element Model of Radiofrequency Ablation with Blood Flow and its Experimental Validation , 2000, Annals of Biomedical Engineering.

[8]  Isaac Chang,et al.  Finite Element Analysis of Hepatic Radiofrequency Ablation Probes using Temperature-Dependent Electrical Conductivity , 2003, Biomedical engineering online.

[9]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .

[10]  Blake Hannaford,et al.  Smart surgical tools and augmenting devices , 2003, IEEE Trans. Robotics Autom..