Determination of loads carried by polypropylene ankle–foot orthoses: A preliminary study

Ankle–foot orthoses (AFOs) are prescribed for the management of gait-related problems. Prescription of AFOs is based on empirical techniques due to the low level of evidence-based research on their efficacy, but primarily poor understanding of their mechanical characteristics. This study aimed to establish a method that would allow the quantification of the contribution of AFOs in the control of the ankle joint during gait. A possible way of achieving this aim would be to measure strain on the AFO during walking by the use of strain gauges. Following successful experimentation with the application of strain gauges to polypropylene tensile specimens, an AFO was instrumented by attaching strain gauges to it so as to allow the moment generated on the AFO in the sagittal plane about the ankle to be measured. Walking trials using this AFO on an able-bodied subject indicated good step-to-step repeatability. The use of an instrumented AFO in conjunction with kinematic and kinetic data acquisition would allow the contribution of the AFO and the residual anatomical loads to be determined. The advantage of such procedure over previously reported ones resides on the use of the actual orthosis being worn by patients thereby conducting tests under real-life situations. It is believed that such analysis of the load actions of an orthosis, which may in future be carried out in three dimensions, would allow a better understanding of the interaction between the leg and the orthosis. This should ultimately enhance AFO prescription criteria and help in optimising patient/device matching.

[1]  Herman J. Woltring,et al.  A fortran package for generalized, cross-validatory spline smoothing and differentiation , 1986 .

[2]  Narender P. Reddy,et al.  Bonding methods for strain gages on polypropylene material , 1996 .

[3]  Adam Rozumalski,et al.  Quantifying the Spring-Like Properties of Ankle-Foot Orthoses (AFOs) , 2007 .

[4]  Analysis of body-device interface forces in the sagittal plane for patients wearing ankle-foot orthoses , 1999, Prosthetics and orthotics international.

[5]  Richard Baker,et al.  ISB recommendation on definition of joint coordinate systems for the reporting of human joint motion-part I: ankle, hip and spine. , 2003, Journal of biomechanics.

[6]  Standard Test Method for Tensile Properties of Plastics 1 , 2022 .

[7]  Dynamic stress analysis of below-knee drop foot braces; Studies on patients with paralysis of the lower limb , 1969, Medical and biological engineering.

[8]  Determination of Stress Distribution In Various Ankle-Foot Orthoses: Experimental Stress Analysis , 1998 .

[9]  J Padovan,et al.  Three-dimensional finite element stress analysis of the polypropylene, ankle-foot orthosis: static analysis. , 1995, Medical engineering & physics.

[10]  Y Suzuki,et al.  Stiffness control in posterior-type plastic ankle-foot orthoses: Effect of ankle trimline Part 2: Orthosis characteristics and orthosis/patient matching , 1996, Prosthetics and orthotics international.

[11]  P. Cappa,et al.  A continuous loading apparatus for measuring three-dimensional stiffness of ankle-foot orthoses. , 2005, Journal of biomechanical engineering.

[12]  S. Miyazaki,et al.  Effect of ankle-foot orthosis on active ankle moment in patients with hemiparesis , 1997, Medical and Biological Engineering and Computing.

[13]  Dynamic strain analysis of below-knee orthopedic braces. A preliminary report. , 1968, American journal of physical medicine.

[14]  S. Miyazaki,et al.  Quantification of the Effect of Dorsi-/ Plantarflexibility of Ankle-Foot Orthoses on Hemiplegic Gait: A Preliminary Report , 1993 .

[15]  H. Houdijk,et al.  Polypropylene Ankle Foot Orthoses to Overcome Drop-Foot Gait in Central Neurological Patients: A Mechanical and Functional Evaluation , 2010, Prosthetics and orthotics international.

[16]  A system for the continuous measurement of ankle joint moment in hemiplegic patients wearing ankle-foot orthoses. , 1993, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.

[17]  J Harlaar,et al.  A new method for evaluating ankle foot orthosis characteristics: BRUCE. , 2009, Gait & posture.

[18]  T.-M. Chu Determination of peak stress on polypropylene ankle-foot orthoses due to weight change using strain gage technology , 2000 .

[20]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[21]  Daniel Vélez Día,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[22]  C. C. Perry Strain-Gage Reinforcement Effects on Low-Modulus Materials , 1985 .

[23]  Sumiko Yamamoto,et al.  Quantification of the effect of the mechanical property of ankle-foot orthoses on hemiplegic gait , 1993 .

[24]  N P Reddy,et al.  Stress distribution in the ankle-foot orthosis used to correct pathological gait. , 1995, Journal of rehabilitation research and development.

[25]  R. Major,et al.  A new structural concept in moulded fixed ankle foot orthoses and comparison of the bending stiffness of four constructions , 2004, Prosthetics and orthotics international.

[26]  Sumiko Yamamoto,et al.  Comparative Study of Mechanical Characteristics of Plastic AFOs , 1993 .

[27]  S Syngellakis,et al.  Assessment of the non-linear behaviour of plastic ankle foot orthoses by the finite element method , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.