Extracting Instantaneous Respiratory Rate From Multiple Photoplethysmogram Respiratory-Induced Variations

In this study, we proposed a novel method for extracting the instantaneous respiratory rate (IRR) from the pulse oximeter photoplethysmogram (PPG). The method was performed in three main steps: (1) a time-frequency transform called synchrosqueezing transform (SST) was used to extract the respiratory-induced intensity, amplitude and frequency variation signals from PPG, (2) the second SST was applied to each extracted respiratory-induced variation signal to estimate the corresponding IRR, and (3) the proposed peak-conditioned fusion method then combined the IRR estimates to calculate the final IRR. We validated the implemented method with capnography and nasal/oral airflow as the reference RR using the limits of agreement (LOA) approach. Compared to simple fusion and single respiratory-induced variation estimations, peak-conditioned fusion shows better performance. It provided a bias of 0.28 bpm with the 95% LOAs ranging from −3.62 to 4.17, validated against capnography and a bias of 0.04 bpm with the 95% LOAs ranging from −5.74 to 5.82, validated against nasal/oral airflow. This algorithm would expand the functionality of a conventional pulse oximetry beyond the measurement of heart rate and oxygen saturation to measure the respiratory rate continuously and instantly.

[1]  L. Tarassenko,et al.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram , 2016, Physiological measurement.

[2]  W. Karlen,et al.  Evaluation of cardiac modulation in children in response to apnea/hypopnea using the Phone Oximeter™ , 2016, Physiological measurement.

[3]  W. Karlen,et al.  Estimating Respiratory and Heart Rates from the Correntropy Spectral Density of the Photoplethysmogram , 2014, PloS one.

[4]  G Y Zou,et al.  Confidence interval estimation for the Bland–Altman limits of agreement with multiple observations per individual , 2013, Statistical methods in medical research.

[5]  Walter Karlen,et al.  Empirical mode decomposition for respiratory and heart rate estimation from the photoplethysmogram , 2013, Computing in Cardiology 2013.

[6]  Walter Karlen,et al.  Multiparameter Respiratory Rate Estimation From the Photoplethysmogram , 2013, IEEE Transactions on Biomedical Engineering.

[7]  L. Tarassenko,et al.  Photoplethysmographic derivation of respiratory rate: a review of relevant physiology , 2012, Journal of medical engineering & technology.

[8]  J. N. Watson,et al.  Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study , 2012, Journal of Clinical Monitoring and Computing.

[9]  Hau-Tieng Wu,et al.  The Synchrosqueezing algorithm for time-varying spectral analysis: Robustness properties and new paleoclimate applications , 2011, Signal Process..

[10]  D. Mant,et al.  Normal ranges of heart rate and respiratory rate in children from birth to 18 years of age: a systematic review of observational studies , 2011, The Lancet.

[11]  I. Daubechies,et al.  Synchrosqueezed wavelet transforms: An empirical mode decomposition-like tool , 2011 .

[12]  Xiang Chen,et al.  Comparison of respiratory-induced variations in photoplethysmographic signals , 2010, Physiological measurement.

[13]  Ki H. Chon,et al.  Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation , 2009, IEEE Transactions on Biomedical Engineering.

[14]  K. Shelley Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate , 2007, Anesthesia and analgesia.

[15]  H. Barnhart,et al.  An Overview on Assessing Agreement with Continuous Measurements , 2007, Journal of biopharmaceutical statistics.

[16]  David R. Burton,et al.  Ridge extraction algorithms for one-dimensional continuous wavelet transform: a comparison , 2007 .

[17]  A. Awad,et al.  The Use of Joint Time Frequency Analysis to Quantify the Effect of Ventilation on the Pulse Oximeter Waveform , 2006, Journal of Clinical Monitoring and Computing.

[18]  Paul S. Addison,et al.  Secondary Transform Decoupling of Shifted nonstationary Signal Modulation Components: Application to Photoplethysmography , 2004, Int. J. Wavelets Multiresolution Inf. Process..

[19]  C. Subbe,et al.  Effect of introducing the Modified Early Warning score on clinical outcomes, cardio‐pulmonary arrests and intensive care utilisation in acute medical admissions * , 2003, Anaesthesia.

[20]  J. Thayer,et al.  Estimating respiratory frequency from autoregressive spectral analysis of heart period. , 2002, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[21]  P. King,et al.  Design Of Pulse Oximeters , 1998, IEEE Engineering in Medicine and Biology Magazine.

[22]  K. Nakajima,et al.  Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. , 1996, Medical engineering & physics.

[23]  D. Wakefield,et al.  Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients , 1993, Journal of General Internal Medicine.

[24]  Olivier Rioul,et al.  Fast algorithms for discrete and continuous wavelet transforms , 1992, IEEE Trans. Inf. Theory.

[25]  R. Merin Monitoring the heart , 1984 .

[26]  K. Wagner Design Of Pulse Oximeters , 2016 .

[27]  Pablo Laguna Lasaosa,et al.  Non-invasive techniques for respiratory information extraction based on pulse photoplethysmogram and electrocardiogram , 2015 .

[28]  Walter Karlen,et al.  Human-centered Phone Oximeter Interface Design for the Operating Room - Pulse Oximeter Interfaced to a Mobile Device for Anesthesia Monitoring in the Developing World , 2011, HEALTHINF.

[29]  Guy A. Dumont,et al.  CapnoBase: Signal database and tools to collect, share and annotate respiratory signals , 2010 .

[30]  PhD David Clifton BEng,et al.  Measurement Of Respiratory Rate From the Photoplethysmogram In Chest Clinic Patients , 2006, Journal of Clinical Monitoring and Computing.

[31]  Paris B Lovett,et al.  The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. , 2005, Annals of emergency medicine.