Systematic design of grid-current-based active damping for grid-connected LCL filters

This work investigates the using of high-pass filter (HPF) of the grid current to actively damp the resonance in grid-connected LCL filters. A new form for such HPF is deduced. Using this form, a systematic co-design procedures for the HPF along with the fundamental current regulator are presented to achieve pre-specified behavior. This behavior includes avoiding the non-minimum phase behavior along with achieving pre-specified requirements of fundamental loop gain and crossover frequency. Numerical example along with the experimental work are introduced at different resonant frequencies.

[1]  Frede Blaabjerg,et al.  Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters , 2016, IEEE Transactions on Power Electronics.

[2]  Donald Grahame Holmes,et al.  Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[3]  Frede Blaabjerg,et al.  Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications , 2016, IEEE Transactions on Power Electronics.

[4]  Xinbo Ruan,et al.  Optimized Controller Design for $LCL$-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance Variation , 2015, IEEE Transactions on Industrial Electronics.

[5]  T.M. Blooming,et al.  Application of IEEE STD 519-1992 Harmonic Limits , 2006, Conference Record of 2006 Annual Pulp and Paper Industry Technical Conference.

[6]  Thomas M. Jahns,et al.  Observer-Based Active Damping of $LCL$ Resonance in Grid-Connected Voltage Source Converters , 2014 .

[7]  Shaojun Xie,et al.  Active Damping-Based Control for Grid-Connected $LCL$ -Filtered Inverter With Injected Grid Current Feedback Only , 2014, IEEE Transactions on Industrial Electronics.

[8]  Jorge A. Solsona,et al.  Full-State Feedback Equivalent Controller for Active Damping in $LCL$-Filtered Grid-Connected Inverters Using a Reduced Number of Sensors , 2015, IEEE Transactions on Industrial Electronics.

[9]  Xinbo Ruan,et al.  Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.

[10]  Frede Blaabjerg,et al.  Virtual RC Damping of LCL-Filtered Voltage Source Converters With Extended Selective Harmonic Compensation , 2015, IEEE Transactions on Power Electronics.

[11]  Frede Blaabjerg,et al.  An Efficient and Robust Hybrid Damper for $LCL$- or $LLCL$-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection , 2016, IEEE Transactions on Industrial Electronics.

[12]  Frede Blaabjerg,et al.  Design and Analysis of Robust Active Damping for LCL Filters Using Digital Notch Filters , 2017, IEEE Transactions on Power Electronics.

[13]  Marko Hinkkanen,et al.  Observer-Based State-Space Current Controller for a Grid Converter Equipped With an LCL Filter: Analytical Method for Direct Discrete-Time Design , 2015, IEEE Transactions on Industry Applications.

[14]  Jiyan Zou,et al.  Delay-Dependent Stability of Single-Loop Controlled Grid-Connected Inverters with LCL Filters , 2016, IEEE Transactions on Power Electronics.

[15]  C. Xia,et al.  Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method , 2015, IEEE Transactions on Power Electronics.

[16]  Xinbo Ruan,et al.  A Real-Time Computation Method With Dual Sampling Mode to Improve the Current Control Performance of the $LCL$-Type Grid-Connected Inverter , 2015, IEEE Transactions on Industrial Electronics.

[17]  Frede Blaabjerg,et al.  Highly Accurate Derivatives for LCL-Filtered Grid Converter With Capacitor Voltage Active Damping , 2016, IEEE Transactions on Power Electronics.

[18]  Frede Blaabjerg,et al.  A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[19]  Shaojun Xie,et al.  Evaluations of current control in weak grid case for grid-connected LCL-filtered inverter , 2013 .