Design and Reliability Analysis of Differential Resistance to Current Conversion Circuit for Biomedical Application of Gas Sensing

Gas sensing in biomedical applications shows a conversion of the concentration of the exhaled gas to a variation in resistance, so an electronic integrated interface circuit is required to analyse the exhaled gases, which are indications for many diseases. In this paper, a resistance to current conversion circuit based on differential biasing for Electronic nose (E-nose) breath analyser is presented. Over more than 5-decades (500Ω to 100MΩ) input resistance range, a precision, less than 1%, required by novel gas sensing system in portable applications, is preserved. Therefore, the proposed circuit obtains high accuracy under simulation. The outputs of the proposed Resistance to Current (R-to-I) conversion circuit achieve a percentage error below 0.25% under environment corners. The reliability of the proposed circuit is also investigated under the effect of process variations. In order to assess the correctness of the proposed architecture, the circuit was compared to similar solutions presented in literature where the proposed architecture attains a worst-case percentage error of 0.05%.

[1]  Vincenzo Stornelli,et al.  A New and Fast-Readout Interface for Resistive Chemical Sensors , 2010, IEEE Transactions on Instrumentation and Measurement.

[2]  Paolo Milani,et al.  The influence of nanoscale morphology on the resistivity of cluster-assembled nanostructured metallic thin films , 2010 .

[3]  Onofrio Resta,et al.  An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. , 2009, Lung cancer.

[4]  A. Baschirotto,et al.  A 141-dB Dynamic Range CMOS Gas-Sensor Interface Circuit Without Calibration With 16-Bit Digital Output Word , 2007, IEEE Journal of Solid-State Circuits.

[5]  David Blaauw,et al.  Wide input range 1.7μW 1.2kS/s resistive sensor interface circuit with 1 cycle/sample logarithmic sub-ranging , 2015, 2015 Symposium on VLSI Circuits (VLSI Circuits).

[6]  Piero Malcovati,et al.  Fundamental Limitations in Resistive Wide-Range Gas-Sensor Interface Circuits Design , 2010 .

[7]  Meng-Fan Chang,et al.  A Low-Power Electronic Nose Signal-Processing Chip for a Portable Artificial Olfaction System , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[8]  A. Baschirotto,et al.  Reconfigurable integrated wide-dynamic-range read-out circuit for MOX gas-sensor grids providing local temperature regulation , 2012, 2012 IEEE Sensors.

[9]  Santiago Celma,et al.  Low-Power Wide-Range Frequency-Output Temperature Sensor , 2014, IEEE Sensors Journal.

[10]  M. Stanacevic,et al.  Nanosensor and Breath Analyzer for Ammonia Detection in Exhaled Human Breath , 2010, IEEE Sensors Journal.

[11]  Alessandra Flammini,et al.  A novel time-controlled interface circuit for resistive sensors , 2011, 2011 IEEE SENSORS Proceedings.

[12]  Hussein Chible,et al.  Wide range resistance to current conversion circuit for resistive gas sensors applications , 2016, 2016 12th Conference on Ph.D. Research in Microelectronics and Electronics (PRIME).

[13]  Kea-Tiong Tang,et al.  An ADC-free adaptive interface circuit of resistive sensor for electronic nose system , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).