Feasibility, accuracy, and incremental value of intraoperative three-dimensional transesophageal echocardiography in valve surgery.

In this prospective trial, intraoperative 2-dimensional (2-D) and 3-dimensional (3-D) transesophageal echocardiography (TEE) examinations were performed on 60 consecutive patients undergoing cardiac valve surgery. Both 2-D (including color flow and Doppler data) and 3-D images were reviewed by blinded observers, and major valvular morphologic findings recorded. In vivo morphologic findings were noted by the surgeon and all explanted valves underwent detailed pathologic examination. To test reproducibility, 6 patients also underwent 3-D TEE 1 day before surgery. A total of 132 of 145 attempted acquisitions (91%) were completed with a mean acquisition time of 2.8 +/- 0.2 minutes. Acquisition time was significantly shorter in patients with regular rhythms. Reconstructions were completed in 121 of 132 scans (92%) and there was at least 1 good reconstruction in 56 of 60 patients (93%). Mean reconstruction time was 8.6 +/- 0.7 minutes. Mean effective 3-D time, which was the time taken to complete an acquisition and a clinically interpretable reconstruction, was 12.2 +/- 0.8 minutes. Intraoperative 3-D echocardiography was clinically feasible in 52 patients (87%). Three-D echocardiography detected most of the major valvular morphologic abnormalities, particularly leaflet perforations, fenestrations, and masses, confirmed on pathologic examination. Three-D echocardiography predicted all salient pathologic findings in 47 patients (84%) with good quality images. In addition, in 15 patients (25%), 3-D echocardiography provided new additional information not provided by 2-D echocardiography, and in 1 case, 3-D echocardiographic findings resulted in a surgeon's decision to perform valve repair rather than replacement. In several instances, 3-D echocardiography provided complementary morphologic information that explained the mechanism of abnormalities seen on 2-D and color flow imaging. In the reproducibility subset, preoperative and intraoperative 3-D imaging detected a similar number of findings when compared with pathology. Thus, in routine clinical intraoperative settings, 3-dimensional TEE is feasible, accurately predicts valve morphology, and provides additional and complementary valvular morphologic information compared with conventional 2-D TEE, and is probably reproducible.

[1]  G. Marx,et al.  Dynamic three-dimensional echocardiographic assessment of intracardiac blood flow jets. , 1995, The American journal of cardiology.

[2]  T. Ryan,et al.  A systematic approach to echocardiographic image acquisition and three-dimensional reconstruction with a subxiphoid rotational scan. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[3]  R A Levine,et al.  A New Integrated System for Three-Dimensional Echocardiographic Reconstruction: Development and Validation for Ventricular Volume with Application in Human Subjects , 1993, Journal of the American College of Cardiology.

[4]  J. Yao,et al.  Three-dimensional echocardiography. , 1998, Current opinion in cardiology.

[5]  N. Pandian,et al.  Clinical Potential of Three‐Dimensional Echocardiography in Endocarditis , 1995 .

[6]  Joseph Kisslo,et al.  Real-time, three-dimensional echocardiography , 1991 .

[7]  J. Marshall,et al.  Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. , 1989, Circulation.

[8]  R. Leischik,et al.  Diagnostic Value of Transesophageal Echocardiography in Cardiac Surgery , 1991, The thoracic and cardiovascular surgeon.

[9]  R A Levine,et al.  Three-dimensional echocardiography: techniques and applications. , 1992, The American journal of cardiology.

[10]  G. Marx,et al.  Dynamic Three‐Dimensional Echocardiography: , 1994 .

[11]  R A Levine,et al.  Three-dimensional echocardiography. In vivo validation for right ventricular volume and function. , 1993, Circulation.

[12]  J. Kisslo,et al.  Real‐Time, Three‐Dimensional Echocardiography: Feasibility and Initial Us , 1991, Echocardiography.

[13]  H Wollschläger,et al.  Three‐Dimensional and Four‐Dimensional Transesophageal Echocardiographic Imaging of the Heart and Aorta in Humans Using a Computed Tomographic Imaging Probe , 1992, Echocardiography.

[14]  T. Bartel,et al.  Left Ventricular Thrombus After Pregnancy , 1996, Echocardiography.

[15]  M. Cahalan,et al.  Cost‐Benefit Analysis of Transesophageal Echocardiography in Cardiac Surgery , 1995, Echocardiography.

[16]  J. Roelandt,et al.  Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  R. Erbel,et al.  Three-dimensional imaging of cardiac mass lesions by transesophageal echocardiographic computed tomography. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[18]  J. Kisslo,et al.  The utility of transesophageal echocardiography and Doppler color flow imaging in patients undergoing cardiac valve surgery. , 1990, Journal of the American College of Cardiology.