An independently addressable microbiosensor array: what are the limits of sensing element density?

A microdisc sensor array, prepared by thin film technology, has been used as a model for miniaturized multi-functional biosensors. It consists of a series of wells, 20 microns in diameter, possessing a 1000 A Pt layer at the bottom that serves as the indicating electrode. The depth of the wells ranged from 2.3-24 microns, depending on the photoresist employed and the spinning speed used to coat the electrode interconnect grid. Ten such wells were arranged in a circular array within an area of radius 130 microns. The center to center distance between any two of the discs ranged from 30 to 155 microns. Each disc is connected by a conductive film line to corresponding pads on the side of the sensor chip. A cylinder placed on top of the chip array formed the electrochemical cell into which a common reference and counter electrode were placed. The reference electrode was operated at ground potential. Prior to the evaluation of enzyme sensors, an assessment of "chemical cross-talk", the perturbation of sensor response resulting from the overlap of proximal diffusion layers, was made using Fe(CN)6(4-). The preliminary conclusion is that the sensing elements probably must be separated by about 100 microns in order to avoid interference from adjacent sensors. A technique was developed for the precision delivery of enzyme and cross-linking agent to the 2.3 microns cavity, having a capacity of 4 pL. This procedure makes possible the preparation of sensor arrays capable of detecting different analytes by employing different enzymes. The sensors gave reasonably rapid (2-4 s) response with linearity (up to about 10 mM. However, the sensors in the center of the array clearly showed the effects of depletion of substrates by the surrounding sensors.

[1]  M. Koudelka-Hep,et al.  Localized Visualization of Chemical Cross-Talk in Microsensor Arrays by Using Scanning Electrochemical Microscopy , 1999 .

[2]  Yiannos Manoli,et al.  Two-Dimensional Imaging of O2, H2O2, and Glucose Distributions by an Array of 400 Individually Addressable Microelectrodes , 1995 .

[3]  K. Aoki,et al.  Linear sweep voltammetry at microband electrodes , 1987 .

[4]  R. Mark Wightman,et al.  Flow rate independent amperometric cell , 1982 .

[5]  H. White,et al.  CHEMICAL DERIVATIZATION OF MICROELECTRODE ARRAYS BY OXIDATION OF PYRROLE AND N-METHYLPYRROLE: FABRICATION OF MOLECULE-BASED ELECTRONIC DEVICES. , 1984 .

[6]  Charles R. Martin,et al.  FABRICATION AND EVALUATION OF NANOELECTRODE ENSEMBLES , 1995 .

[7]  K. Morita,et al.  Microhole array electrode as a glucose sensor. , 1990 .

[8]  J M Cooper,et al.  Towards electronic Petri dishes and picolitre-scale single-cell technologies. , 1999, Trends in biotechnology.

[9]  G. Gerhardt,et al.  Fabrication and characterization of sputtered-carbon microelectrode arrays. , 1996, Analytical chemistry.

[10]  T. Matsue,et al.  Electrochemical response at microarray electrodes in flowing streams and determination of catecholamines , 1990 .

[11]  Yoshio Hanazato,et al.  Glucose sensor based on a field-effect transistor with a photolithographically patterned glucose oxidase membrane , 1987 .

[12]  M. Morita,et al.  Carbon Film-Based Interdigitated Ring Array Electrodes as Detectors in Radial Flow Cells , 1996 .

[13]  C. Henry,et al.  Microcavities Containing Individually Addressable Recessed Microdisk and Tubular Nanoband Electrodes , 1999 .

[14]  J. L. Anderson,et al.  Numerical simulation of convective diffusion at a microarray channel electrode , 1985 .

[15]  R. Lal,et al.  A biosensor array based on polyaniline. , 1996, Analytical chemistry.

[16]  S. Weber,et al.  Signal-to-noise ratio in microelectrode-array-based electrochemical detectors. , 1989, Analytical chemistry.

[17]  K. Morita,et al.  Microhole array for oxygen electrode , 1989 .

[18]  Isao Karube,et al.  A Micro Planar Ampehometric Glucose Sensor Using an Isfet as a Reference Electrode , 1986 .

[19]  T. Matsue,et al.  Electrochemical behaviour of V-groove microelectrodes fabricated by micromachining , 1995 .

[20]  B Ross,et al.  Biosensor on the base of polypyrrole modified ultramicroelectrode arrays. , 1994, Talanta.

[21]  Hisao Tabei,et al.  Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency , 1990 .

[22]  J. L. Anderson,et al.  Optimization of microelectrode array geometry in a rectangular flow channel detector , 1986 .

[23]  K. Moxon,et al.  Ceramic-based multisite microelectrodes for electrochemical recordings. , 2000, Analytical chemistry.

[24]  Andrew G. Ewing,et al.  Ultrasmall Enzyme Electrodes with Response Time Less than 100 Milliseconds , 1999 .

[25]  I. Karube,et al.  Integrated biosensor for glucose and galactose , 1989 .

[26]  R. Murray,et al.  Interdigitated Array Electrode Diffusion Measurements in Donor/Acceptor Solutions in Polyether Electrolyte Solvents , 1991 .

[27]  Giovanna Marrazza,et al.  INK-JET PRINTING FOR THE FABRICATION OF AMPEROMETRIC GLUCOSE BIOSENSORS , 1992 .