Detailed Off-Line Parameter Identification of Synchronous Generator Based on Frequency Response Tests

This work presents a general methodology, based on standstill frequency response tests. Once the circuit topology is chosen, it allows a systematic calculation of the circuit parameters for a salient pole synchronous generator. The order of the circuit considered can be whatever, even a customized circuit topology, since the methodology does not rely on a specific formulation. The transfer function coefficients are expressed as a function of the circuit parameters by using the symbolic Matlab toolbox. From tests, the coefficients of the transfer function are fitted in both axes. Then the coefficients have to match with the symbolic transfer function previously obtained in order to calculate the circuit parameters. If the dynamic behavior obtained with the fitted parameters is not accurate enough, the circuit order is increased until attaining an accurate solution. This methodology results in a useful educational tool for machine characterization. Nowadays many methods are found in the technical literature to calculate such parameters, although most of them computationally demanding.

[1]  Ed.C. Bortoni,et al.  A standstill frequency response method for large salient pole synchronous machines , 2004, IEEE Transactions on Energy Conversion.

[2]  Mehdi Karrari,et al.  Simultaneous Parameter Identification of Synchronous Generator and Excitation System Using Online Measurements , 2016, IEEE Transactions on Smart Grid.

[3]  Jean-Jacques Simond,et al.  Two Full Parameter Identification Methods for Synchronous Machine Applying DC-Decay Tests for a Rotor in Arbitrary Position , 2017, IEEE Transactions on Industry Applications.

[4]  Stéphane Caux,et al.  Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators , 2015, IEEE Transactions on Industrial Electronics.

[5]  O.P. Malik,et al.  Identification of physical parameters of a synchronous Generator from online measurements , 2004, IEEE Transactions on Energy Conversion.

[6]  S. Tnani,et al.  Identification of synchronous machine by Standstill Frequency Response (SSFR) method - influence of the stator resistance - , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[7]  Ali Keyhani,et al.  Neural network observers for on-line tracking of synchronous generator parameters , 1999 .

[8]  Ali Keyhani,et al.  An algebraic approach for identifying operating point dependent parameters of synchronous machines using orthogonal series expansions , 2001 .

[9]  Antonio Griffo,et al.  Design and Characterization of a Three-Phase Brushless Exciter for Aircraft Starter/Generator , 2013, IEEE Transactions on Industry Applications.

[10]  I. Kamwa,et al.  Cross-Identification of Synchronous Generator Parameters From RTDR Test Time-Domain Analytical Responses , 2011, IEEE Transactions on Energy Conversion.

[11]  Š.,et al.  Neural Network Observers for On-line Tracking of Synchronous Generator Parameters , 2004 .

[12]  Tine L. Vandoorn,et al.  Generation of Multisinusoidal Test Signals for the Identification of Synchronous-Machine Parameters by Using a Voltage-Source Inverter , 2010, IEEE Transactions on Industrial Electronics.

[13]  R. M. Saunders Synchronous-machine standstill frequency-response test data analysis , 1991 .

[14]  Johan Bladh,et al.  Standstill Frequency Response Test on a Synchronous Machine Extended With Damper Bar Measurements , 2016, IEEE Transactions on Energy Conversion.

[15]  Ali Keyhani,et al.  Synchronous generator model identification and parameter estimation from operating data , 2003 .