ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II

Purpose To present the most updated American College of Radiology (ACR) Appropriateness Criteria formed by an expert panel on the appropriate delivery of external beam radiation to manage stage T1 and T2 prostate cancer (in the definitive setting and post-prostatectomy) and to provide clinical variants with expert recommendations based on accompanying Appropriateness Criteria for target volumes and treatment planning. Methods and materials The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a panel of multidisciplinary experts. The guideline development and revision process includes an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In instances in which evidence is lacking or equivocal, expert opinion may supplement available evidence to recommend imaging or treatment. Results The panel summarizes the most recent and relevant literature on the topic, including organ motion and localization methods, image guidance, and delivery techniques (eg, 3-dimensional conformal intensity modulation). The panel presents 7 clinical variants, including (1) a standard case and cases with (2) a distended rectum, (3) a large-volume prostate, (4) bilateral hip implants, (5) inflammatory bowel disease, (6) prior prostatectomy, and (7) a pannus extending into the radiation field. Each case outlines the appropriate techniques for simulation, treatment planning, image guidance, dose, and fractionation. Numerical rating and commentary is given for each treatment approach in each variant. Conclusions External beam radiation is a key component of the curative management of T1 and T2 prostate cancer. By combining the most recent medical literature, these Appropriateness Criteria can aid clinicians in determining the appropriate treatment delivery and personalized approaches for individual patients.

[1]  M. Hoogeman,et al.  Increased risk of biochemical and clinical failure for prostate patients with a large rectum at radiotherapy planning: results from the Dutch trial of 68 GY versus 78 Gy. , 2007, International journal of radiation oncology, biology, physics.

[2]  R. Peschel,et al.  Radical prostatectomy vs. intensity-modulated radiation therapy in the management of localized prostate adenocarcinoma. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Roberto Passariello,et al.  Role of dynamic contrast-enhanced magnetic resonance (MR) imaging and proton MR spectroscopic imaging in the detection of local recurrence after radical prostatectomy for prostate cancer. , 2008, European urology.

[4]  Jinkoo Kim,et al.  Examining margin reduction and its impact on dose distribution for prostate cancer patients undergoing daily cone-beam computed tomography. , 2008, International journal of radiation oncology, biology, physics.

[5]  Patrick A Kupelian,et al.  Observations on real-time prostate gland motion using electromagnetic tracking. , 2008, International journal of radiation oncology, biology, physics.

[6]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[7]  E. Horwitz,et al.  Impact of obesity on outcomes after definitive dose‐escalated intensity‐modulated radiotherapy for localized prostate cancer , 2015, Cancer.

[8]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Tom Vercauteren,et al.  Delineation of the postprostatectomy prostate bed using computed tomography: interobserver variability following the EORTC delineation guidelines. , 2011, International journal of radiation oncology, biology, physics.

[10]  E. Plimack,et al.  Evaluating toxicity from definitive radiation therapy for prostate cancer in men with inflammatory bowel disease: Patient selection and dosimetric parameters with modern treatment techniques. , 2015, Practical radiation oncology.

[11]  N. Ferris,et al.  Seminal vesicle intrafraction motion analysed with cinematic magnetic resonance imaging , 2014, Radiation oncology.

[12]  M. Zelefsky,et al.  Neoadjuvant androgen ablation prior to radiotherapy for prostate cancer: reducing the potential morbidity of therapy. , 1997, Urology.

[13]  Mary Feng,et al.  Radiographic and anatomic basis for prostate contouring errors and methods to improve prostate contouring accuracy. , 2010, International journal of radiation oncology, biology, physics.

[14]  Bhudatt R Paliwal,et al.  A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments. , 2009, International journal of radiation oncology, biology, physics.

[15]  M. Colombel,et al.  Prostate hypofractionated radiation therapy: injection of hyaluronic acid to better preserve the rectal wall. , 2013, International journal of radiation oncology, biology, physics.

[16]  Mark K Buyyounouski,et al.  Prostate bed motion during intensity-modulated radiotherapy treatment. , 2011, International journal of radiation oncology, biology, physics.

[17]  Shinichi Shimizu,et al.  Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. , 2002, International journal of radiation oncology, biology, physics.

[18]  Josephine Kang,et al.  Quality of Life and Toxicity after SBRT for Organ-Confined Prostate Cancer, a 7-Year Study , 2014, Front. Oncol..

[19]  O. Cahlon,et al.  Anterior-oriented proton beams for prostate cancer: A multi-institutional experience , 2015, Acta oncologica.

[20]  Patrick A Kupelian,et al.  Influence of intrafraction motion on margins for prostate radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[21]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[22]  Steve P Lee,et al.  Effect of pelvic lymph node irradiation in salvage therapy for patients with prostate cancer with a biochemical relapse following radical prostatectomy. , 2004, Clinical prostate cancer.

[23]  Cedric X. Yu,et al.  Dosimetric effects of the prone and supine positions on image guided localized prostate cancer radiotherapy. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  R. Pötter,et al.  The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[25]  M. McKay,et al.  Implementation of an image guided intensity‐modulated protocol for post‐prostatectomy radiotherapy: Planning data and acute toxicity outcomes , 2013, Journal of medical imaging and radiation oncology.

[26]  J. Staffurth,et al.  Clinical application of image-guided radiotherapy in bladder and prostate cancer. , 2010, Clinical oncology (Royal College of Radiologists (Great Britain)).

[27]  Josef Nilsson,et al.  Prostate volume determination: differential volume measurements comparing CT and TRUS. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  M van Herk,et al.  Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.

[29]  M. Schell,et al.  Stereotactic body radiation therapy: the report of AAPM Task Group 101. , 2010, Medical physics.

[30]  Jean Pouliot,et al.  Daily electronic portal imaging for morbidly obese men undergoing radiotherapy for localized prostate cancer. , 2004, International journal of radiation oncology, biology, physics.

[31]  L. F. Cazzaniga,et al.  Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[32]  S. Pokharel,et al.  Radiobiological case study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses , 2015, South Asian Journal of Cancer.

[33]  J. Ciezki,et al.  Outcomes for intermediate risk prostate cancer: are there advantages for surgery, external radiation, or brachytherapy? , 2009, Urologic oncology.

[34]  D. Kuban,et al.  Long-term failure patterns and survival in a randomized dose-escalation trial for prostate cancer. Who dies of disease? , 2008, International journal of radiation oncology, biology, physics.

[35]  J. Deasy,et al.  Radiation dose-volume effects and the penile bulb. , 2010, International journal of radiation oncology, biology, physics.

[36]  M. Eble,et al.  Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[37]  M. Flentje,et al.  Adverse effect of a distended rectum in intensity-modulated radiotherapy (IMRT) treatment planning of prostate cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[38]  Tian Liu,et al.  Comparison of Image-guided Radiotherapy Technologies for Prostate Cancer , 2014, American journal of clinical oncology.

[39]  Yong Eun Chung,et al.  Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility. , 2014, AJR. American journal of roentgenology.

[40]  P. Keall,et al.  Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. , 2003, Medical physics.

[41]  P. Greer,et al.  Comparison of prostate set‐up accuracy and margins with off‐line bony anatomy corrections and online implanted fiducial‐based corrections , 2008, Journal of medical imaging and radiation oncology.

[42]  Radhe Mohan,et al.  Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[43]  K. Brock,et al.  A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers. , 2007, International journal of radiation oncology, biology, physics.

[44]  W. Jackson,et al.  Age and comorbid illness are associated with late rectal toxicity following dose-escalated radiation therapy for prostate cancer. , 2013, International journal of radiation oncology, biology, physics.

[45]  Patrick A. Kupelian,et al.  Hypofractionated intensity-modulated radiotherapy (70 Gy at 2.5 Gy per fraction) for localized prostate cancer: Cleveland Clinic experience. , 2007, International journal of radiation oncology, biology, physics.

[46]  F. Montorsi,et al.  Is seminal vesicle ablation mandatory for all patients undergoing radical prostatectomy? A multivariate analysis on 1283 patients. , 2004, European urology.

[47]  J Frantzis,et al.  Clinician's guide to prostate IMRT plan assessment and optimisation , 2010, Journal of medical imaging and radiation oncology.

[48]  J. Montie,et al.  Functional anatomy of the prostate: implications for treatment planning. , 2005, International journal of radiation oncology, biology, physics.

[49]  Jürgen Hesser,et al.  Accuracy of ultrasound-based (BAT) prostate-repositioning: a three-dimensional on-line fiducial-based assessment with cone-beam computed tomography. , 2008, International journal of radiation oncology, biology, physics.

[50]  Alexander Markovic,et al.  Quality assurance of U.S.-guided external beam radiotherapy for prostate cancer: report of AAPM Task Group 154. , 2011, Medical physics.

[51]  E. B. Butler,et al.  Is there a role for endorectal balloons in prostate radiotherapy? A systematic review. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[52]  M. Lai,et al.  Using Cone-Beam Computed Tomography to Evaluate the Impact of Bladder Filling Status on Target Position in Prostate Radiotherapy , 2009, Strahlentherapie und Onkologie.

[53]  J M Balter,et al.  A comparison of ventilatory prostate movement in four treatment positions. , 2000, International journal of radiation oncology, biology, physics.

[54]  C C Ling,et al.  Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[55]  J. Cheville,et al.  Prediction of radial distance of extraprostatic extension from pretherapy factors. , 2007, International journal of radiation oncology, biology, physics.

[56]  A. D'Amico,et al.  DEFINITIVE EXTERNAL-BEAM IRRADIATION IN STAGE T1 AND T2 PROSTATE CANCER , 2013 .

[57]  S. Lott,et al.  Radiation therapy for adenocarcinoma of the prostate. , 1979, Canadian journal of surgery. Journal canadien de chirurgie.

[58]  Uwe Oelfke,et al.  A quantitative image quality comparison of four different image guided radiotherapy devices. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[59]  Dwight E Heron,et al.  A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment , 2009, Physics in medicine and biology.

[60]  J. Deasy,et al.  Radiation dose-volume effects in radiation-induced rectal injury. , 2010, International journal of radiation oncology, biology, physics.

[61]  H. Sandler,et al.  Initial Results of a Phase 3 Randomized Study of High Dose 3DCRT/IMRT versus Standard Dose 3D-CRT/IMRT in Patients Treated for Localized Prostate Cancer (RTOG 0126) , 2014 .

[62]  Randall K Ten Haken,et al.  Guest editor's introduction to QUANTEC: a users guide. , 2010, International journal of radiation oncology, biology, physics.

[63]  John Wong,et al.  Accuracy of a wireless localization system for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[64]  P. Voet,et al.  Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: comparison of different planning strategies. , 2013, Medical physics.

[65]  Y. Yamada,et al.  ACR Appropriateness Criteria® Definitive External Beam Irradiation in Stage T1 and T2 Prostate Cancer , 2011, American journal of clinical oncology.

[66]  A. Renshaw,et al.  Biochemical Outcome after radical prostatectomy, external beam Radiation Therapy, or interstitial Radiation therapy for clinically localized prostate cancer , 1998 .

[67]  A. Rees,et al.  Intensity-modulated radiotherapy for the treatment of prostate cancer: a systematic review and economic evaluation. , 2010, Health technology assessment.

[68]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[69]  C. Ménard,et al.  Boosting imaging defined dominant prostatic tumors: a systematic review. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[70]  Radhe Mohan,et al.  Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants? , 2008, Physics in medicine and biology.

[71]  Y. Lotan,et al.  Phase I dose-escalation study of stereotactic body radiation therapy for low- and intermediate-risk prostate cancer. , 2011, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[72]  M. V. van Herk,et al.  The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients. , 2008, International journal of radiation oncology, biology, physics.

[73]  M. Zelefsky,et al.  Improved clinical outcomes with high-dose image guided radiotherapy compared with non-IGRT for the treatment of clinically localized prostate cancer. , 2012, International journal of radiation oncology, biology, physics.

[74]  D. Dearnaley,et al.  Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[75]  Nicholas G Zaorsky,et al.  Systematic review of hypofractionated radiation therapy for prostate cancer. , 2013, Cancer treatment reviews.

[76]  P. Wust,et al.  Image-guided radiotherapy with implanted markers and kilovoltage imaging and 6-dimensional position corrections for intrafractional motion of the prostate. , 2013, Anticancer research.

[77]  He Wang,et al.  An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer. , 2005, International journal of radiation oncology, biology, physics.

[78]  Vitali Moiseenko,et al.  Effect of bladder filling on doses to prostate and organs at risk: a treatment planning study , 2007, Journal of applied clinical medical physics.

[79]  J. Kaanders,et al.  Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[80]  S. Kalnicki,et al.  Application of an interstitial and biodegradable balloon system for prostate-rectum separation during prostate cancer radiotherapy: a prospective multi-center study , 2013, Radiation Oncology.

[81]  C. Hosford,et al.  Human collagen injections to reduce rectal dose during radiotherapy. , 2012, International journal of radiation oncology, biology, physics.

[82]  Issam El-Naqa,et al.  Variation in the definition of clinical target volumes for pelvic nodal conformal radiation therapy for prostate cancer. , 2007, International journal of radiation oncology, biology, physics.

[83]  Kyounghwa Bae,et al.  Randomized trial comparing conventional-dose with high-dose conformal radiation therapy in early-stage adenocarcinoma of the prostate: long-term results from proton radiation oncology group/american college of radiology 95-09. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[84]  F. Lohr,et al.  Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[85]  L. Pérez-Romasanta,et al.  CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans , 2009, Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico.

[86]  J. Malicki,et al.  Dosimetric consequences of prostate-based couch shifts on the precision of dose delivery during simultaneous IMRT irradiation of the prostate, seminal vesicles and pelvic lymph nodes. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[87]  G. Merrick,et al.  ACR appropriateness criteria postradical prostatectomy irradiation in prostate cancer. , 2011, American journal of clinical oncology.

[88]  A. D'Amico,et al.  ACR appropriateness Criteria® Postradical prostatectomy irradiation in prostate cancer. , 2014, Oncology.

[89]  Lawrence B Marks,et al.  Radiation dose-volume effects of the urinary bladder. , 2010, International journal of radiation oncology, biology, physics.

[90]  V. Gebski,et al.  A randomized trial evaluating rigid immobilization for pelvic irradiation. , 2003, International journal of radiation oncology, biology, physics.

[91]  O. Zeidan,et al.  Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric‐modulated arc therapy , 2014, Journal of applied clinical medical physics.

[92]  A. Jemal,et al.  Cancer statistics, 2015 , 2015, CA: a cancer journal for clinicians.

[93]  Nicholas G Zaorsky,et al.  Stereotactic body radiation therapy for prostate cancer: is the technology ready to be the standard of care? , 2013, Cancer treatment reviews.

[94]  A. Dicker,et al.  Post‐prostatectomy image‐guided radiation therapy: Evaluation of toxicity and inter‐fraction variation using online cone‐beam CT , 2011, Journal of medical imaging and radiation oncology.

[95]  D. Kuban,et al.  Influence of obesity on biochemical and clinical failure after external‐beam radiotherapy for localized prostate cancer , 2006, Cancer.

[96]  Peter Wust,et al.  Potentials of on-line repositioning based on implanted fiducial markers and electronic portal imaging in prostate cancer radiotherapy , 2009, Radiation oncology.

[97]  奥村 雅彦 A PROSPECTIVE STUDY OF INTRAFRACTION PROSTATE MOTION IN THE PRONE VS. SUPINE POSITION , 2011 .

[98]  K. Yenice,et al.  Image-guided radiation therapy for prostate cancer: A computed tomography-based assessment of fiducial marker migration between placement and 7 days. , 2015, Practical radiation oncology.

[99]  Marcel van Herk,et al.  Target definition in prostate, head, and neck. , 2005, Seminars in radiation oncology.

[100]  Nicholas G Zaorsky,et al.  Evolution of advanced technologies in prostate cancer radiotherapy , 2013, Nature Reviews Urology.

[101]  H. Patrocinio,et al.  An assessment of PTV margin definitions for patients undergoing conformal 3D external beam radiation therapy for prostate cancer based on an analysis of 10,327 pretreatment daily ultrasound localizations. , 2007, International journal of radiation oncology, biology, physics.

[102]  Amita Shukla-Dave,et al.  Functional magnetic resonance imaging in prostate cancer. , 2009, European urology.

[103]  Rajat J Kudchadker,et al.  Changes in the pelvic anatomy after an IMRT treatment fraction of prostate cancer. , 2007, International journal of radiation oncology, biology, physics.

[104]  R. Steenbakkers,et al.  Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate. , 2003, International journal of radiation oncology, biology, physics.

[105]  Filip Claus,et al.  Interobserver Delineation Variation Using CT versus Combined CT + MRI in Intensity–Modulated Radiotherapy for Prostate Cancer , 2005, Strahlentherapie und Onkologie.

[106]  Patrick A Kupelian,et al.  An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic tracking. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[107]  K. Herfarth,et al.  Megavoltage CT in Helical Tomotherapy — Clinical Advantages and Limitations of Special Physical Characteristics , 2009, Technology in cancer research & treatment.

[108]  C. Morash,et al.  Postoperative radiotherapy in prostate cancer: the case of the missing target. , 2010, International journal of radiation oncology, biology, physics.

[109]  Ivan Buzurovic,et al.  Implanted dosimeters identify radiation overdoses during IMRT for prostate cancer. , 2012, International journal of radiation oncology, biology, physics.

[110]  K. Herfarth,et al.  A multi-institutional clinical trial of rectal dose reduction via injected polyethylene-glycol hydrogel during intensity modulated radiation therapy for prostate cancer: analysis of dosimetric outcomes. , 2013, International journal of radiation oncology, biology, physics.

[111]  M. Santoro,et al.  Stereotactic Body Radiation Therapy for Low, Intermediate, and High-risk Prostate Cancer: Disease Control and Quality of Life , 2011 .

[112]  B. Trock,et al.  An updated prostate cancer staging nomogram (Partin tables) based on cases from 2006 to 2011 , 2013, BJU international.

[113]  E. Schreibmann,et al.  Boost first, eliminate systematic error, and individualize CTV to PTV margin when treating lymph nodes in high-risk prostate cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[114]  D. Kuban,et al.  Local recurrence map to guide target volume delineation after radical prostatectomy. , 2014, Practical radiation oncology.

[115]  M. Colombel,et al.  Dosimetric implications of an injection of hyaluronic acid for preserving the rectal wall in prostate stereotactic body radiation therapy. , 2014, International journal of radiation oncology, biology, physics.

[116]  Marcel van Herk,et al.  Errors and margins in radiotherapy. , 2004, Seminars in radiation oncology.

[117]  M. Whitaker,et al.  Constrained‐beam inverse planning for intensity‐modulated radiation therapy of prostate cancer patients with bilateral hip prostheses , 2012, Journal of medical imaging and radiation oncology.

[118]  J. Dempsey,et al.  Cine-Magnetic Resonance Imaging Assessment of Intrafraction Motion for Prostate Cancer Patients Supine or Prone With and Without a Rectal Balloon , 2010, American journal of clinical oncology.

[119]  Steven J Frank,et al.  Quantification of prostate and seminal vesicle interfraction variation during IMRT. , 2008, International journal of radiation oncology, biology, physics.

[120]  C. Deville,et al.  Comparative toxicity and dosimetric profile of whole-pelvis versus prostate bed-only intensity-modulated radiation therapy after prostatectomy. , 2012, International journal of radiation oncology, biology, physics.

[121]  Baris Turkbey,et al.  Multiparametric MRI and prostate cancer diagnosis and risk stratification , 2012, Current opinion in urology.

[122]  Qiuwen Wu,et al.  Geometric and dosimetric evaluations of an online image-guidance strategy for 3D-CRT of prostate cancer. , 2006, International journal of radiation oncology, biology, physics.

[123]  B. Heijmen,et al.  Intensity modulated radiation therapy planning for patients with a metal hip prosthesis based on class solutions. , 2012, Practical radiation oncology.

[124]  G. Lockwood,et al.  A cinematic magnetic resonance imaging study of milk of magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion. , 2010, International journal of radiation oncology, biology, physics.

[125]  David A Jaffray,et al.  On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma. , 2004, International journal of radiation oncology, biology, physics.

[126]  M. Parmar,et al.  Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer: first results from the MRC RT01 randomised controlled trial. , 2007, The Lancet. Oncology.

[127]  Ashesh B Jani,et al.  A case study of radiotherapy planning for a bilateral metal hip prosthesis prostate cancer patient. , 2005, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[128]  R K Ten Haken,et al.  The effect of patient position and treatment technique in conformal treatment of prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[129]  M. Santoro,et al.  Stereotactic Body Radiotherapy as Boost for Organ-confined Prostate Cancer , 2010, Technology in cancer research & treatment.

[130]  M. Anscher,et al.  Interstitial biodegradable balloon for reduced rectal dose during prostate radiotherapy: results of a virtual planning investigation based on the pre- and post-implant imaging data of an international multicenter study. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[131]  Jan-Jakob Sonke,et al.  Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179. , 2012, Medical physics.

[132]  C. Fiorino,et al.  Megavoltage CT Images of Helical Tomotherapy Unit for Radiation Treatment Simulation: Impact on Feasibility of Treatment Planning in a Prostate Cancer Patient with Bilateral Femoral Prostheses , 2011, Tumori.

[133]  J. Lebesque,et al.  Update of Dutch multicenter dose-escalation trial of radiotherapy for localized prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[134]  Patrick W McLaughlin,et al.  Vessel-sparing prostate radiotherapy: dose limitation to critical erectile vascular structures (internal pudendal artery and corpus cavernosum) defined by MRI. , 2005, International journal of radiation oncology, biology, physics.

[135]  Jean Pouliot,et al.  Dose recalculation and the Dose-Guided Radiation Therapy (DGRT) process using megavoltage cone-beam CT. , 2009, International journal of radiation oncology, biology, physics.

[136]  Michel Bolla,et al.  Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[137]  Sean S. Park,et al.  Adaptive image-guided radiotherapy (IGRT) eliminates the risk of biochemical failure caused by the bias of rectal distension in prostate cancer treatment planning: clinical evidence. , 2012, International journal of radiation oncology, biology, physics.

[138]  David C. Miller,et al.  Prostate Cancer,,Version 2.2014 Clinical Practice Guidelines in Oncology , 2014 .

[139]  S. Hui,et al.  Assessing prostate, bladder and rectal doses during image guided radiation therapy — need for plan adaptation? , 2009, Journal of applied clinical medical physics.

[140]  G. Soete,et al.  Impact of planning target volume margins and rectal distention on biochemical failure in image-guided radiotherapy of prostate cancer. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[141]  Valeria Panebianco,et al.  Advances in magnetic resonance imaging: how they are changing the management of prostate cancer. , 2011, European urology.

[142]  Michel Bolla,et al.  Guidelines for primary radiotherapy of patients with prostate cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[143]  K. Odrážka,et al.  Magnetic resonance imaging in postprostatectomy radiotherapy planning. , 2012, International journal of radiation oncology, biology, physics.

[144]  Lei Dong,et al.  Anatomic variation and dosimetric consequences of neoadjuvant hormone therapy before radiation therapy for prostate cancer. , 2013, Practical radiation oncology.

[145]  F. Lohr,et al.  Stereotactic ultrasound for target volume definition in a patient with prostate cancer and bilateral total hip replacement. , 2015, Practical radiation oncology.

[146]  Chris Beltran,et al.  Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods. , 2008, International journal of radiation oncology, biology, physics.

[147]  S. Pokharel,et al.  A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses , 2014, South Asian Journal of Cancer.

[148]  Issam El-Naqa,et al.  RTOG GU Radiation oncology specialists reach consensus on pelvic lymph node volumes for high-risk prostate cancer. , 2009, International journal of radiation oncology, biology, physics.

[149]  D. Nori,et al.  Prostate and seminal vesicle volume based consideration of prostate cancer patients for treatment with 3D-conformal or intensity-modulated radiation therapy. , 2010, Medical physics.

[150]  Jennifer Croke,et al.  Postoperative radiotherapy for prostate cancer: a comparison of four consensus guidelines and dosimetric evaluation of 3D-CRT versus tomotherapy IMRT. , 2012, International journal of radiation oncology, biology, physics.

[151]  A. Koong,et al.  Low Toxicity in Inflammatory Bowel Disease Patients Treated With Abdominal and Pelvic Radiation Therapy , 2015, American journal of clinical oncology.

[152]  D. Bottomley,et al.  The use of CT-MR image registration to define target volumes in pelvic radiotherapy in the presence of bilateral hip replacements. , 2005, The British journal of radiology.

[153]  Patrick A Kupelian,et al.  Image-guided radiotherapy for localized prostate cancer: treating a moving target. , 2008, Seminars in radiation oncology.

[154]  S. Hancock,et al.  Radiotherapy after prostatectomy: improved biochemical relapse-free survival with whole pelvic compared with prostate bed only for high-risk patients. , 2007, International journal of radiation oncology, biology, physics.

[155]  Di Yan,et al.  Comparison of various online IGRT strategies: The benefits of online treatment plan re-optimization. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[156]  V Grégoire,et al.  State of the art on dose prescription, reporting and recording in Intensity-Modulated Radiation Therapy (ICRU report No. 83). , 2011, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[157]  C. Pelizzari,et al.  Late toxicity and quality of life after definitive treatment of prostate cancer: redefining optimal rectal sparing constraints for intensity-modulated radiation therapy , 2014, Cancer medicine.

[158]  E. Yang,et al.  Reduction of dose delivered to organs at risk in prostate cancer patients via image-guided radiation therapy. , 2010, International journal of radiation oncology, biology, physics.

[159]  J. Galvin,et al.  Preliminary toxicity analysis of 3-dimensional conformal radiation therapy versus intensity modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group 0126 prostate cancer trial. , 2013, International journal of radiation oncology, biology, physics.

[160]  P. Maingon,et al.  70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial. , 2011, International journal of radiation oncology, biology, physics.

[161]  D. Tremblay,et al.  Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[162]  Ronald C. Chen,et al.  Intensity-modulated radiation therapy, proton therapy, or conformal radiation therapy and morbidity and disease control in localized prostate cancer. , 2012, JAMA.

[163]  Qiuwen Wu,et al.  The role of seminal vesicle motion in target margin assessment for online image-guided radiotherapy for prostate cancer. , 2009, International journal of radiation oncology, biology, physics.

[164]  Issam El Naqa,et al.  Development of RTOG consensus guidelines for the definition of the clinical target volume for postoperative conformal radiation therapy for prostate cancer. , 2010, International journal of radiation oncology, biology, physics.

[165]  R. C. Susil,et al.  Effects of prostate-rectum separation on rectal dose from external beam radiotherapy. , 2010, International journal of radiation oncology, biology, physics.

[166]  Cedric X. Yu,et al.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. , 2003, Medical physics.

[167]  D. D. de Jong,et al.  Reduced late rectal mucosal changes after prostate three-dimensional conformal radiotherapy with endorectal balloon as observed in repeated endoscopy. , 2007, International journal of radiation oncology, biology, physics.

[168]  A. Markoe,et al.  Clinical outcome of patients treated with 3D conformal radiation therapy (3D-CRT) for prostate cancer on RTOG 9406. , 2004, International journal of radiation oncology, biology, physics.

[169]  A. D'Amico,et al.  Motion and shape change when using an endorectal balloon during prostate radiation therapy. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[170]  R. Timmerman,et al.  Stereotactic Body Radiation Therapy for Prostate Cancer: Review of Experience of a Multicenter Phase I/II Dose-Escalation Study , 2014, Front. Oncol..

[171]  Rick Chappell,et al.  Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[172]  D. Yan,et al.  Treatment of prostate cancer with radiotherapy: should the entire seminal vesicles be included in the clinical target volume? , 2002, International journal of radiation oncology, biology, physics.

[173]  Masoom A Haider,et al.  Anatomic boundaries of the clinical target volume (prostate bed) after radical prostatectomy. , 2007, International journal of radiation oncology, biology, physics.

[174]  Jeremy L Millar,et al.  Post-prostatectomy radiation therapy: consensus guidelines of the Australian and New Zealand Radiation Oncology Genito-Urinary Group. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[175]  J Szanto,et al.  Respiratory-induced prostate motion: quantification and characterization. , 2000, International journal of radiation oncology, biology, physics.

[176]  Alan Pollack,et al.  MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT. , 2004, International journal of radiation oncology, biology, physics.

[177]  A. Zarkar,et al.  Which bowel preparation is best? Comparison of a high-fibre diet leaflet, daily microenema and no preparation in prostate cancer patients treated with radical radiotherapy to assess the effect on planned target volume shifts due to rectal distension. , 2013, The British journal of radiology.

[178]  Michael G Herman,et al.  Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging. , 2005, International journal of radiation oncology, biology, physics.

[179]  Wendy L. Smith,et al.  Prostate volume contouring: a 3D analysis of segmentation using 3DTRUS, CT, and MR. , 2007, International journal of radiation oncology, biology, physics.

[180]  Peter Wust,et al.  Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer. , 2012, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[181]  Vickie Kong,et al.  A randomized comparison of interfraction and intrafraction prostate motion with and without abdominal compression. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[182]  N. Lawrentschuk,et al.  Fiducial markers and spacers in prostate radiotherapy: current applications , 2014, BJU international.

[183]  R. Stoyanova,et al.  Randomized trial of hypofractionated external-beam radiotherapy for prostate cancer. , 2013, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[184]  F. Vicini,et al.  Prostate volume reduction with androgen deprivation therapy before interstitial brachytherapy. , 2002, The Journal of urology.

[185]  J. Michalski,et al.  Three-dimensional conformal therapy versus standard radiation therapy in localized carcinoma of prostate: an update. , 2002, Clinical prostate cancer.

[186]  C. C. Parkera,et al.  Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration , 2003 .

[187]  B. Jacobs,et al.  Dosimetric outcomes in prostate brachytherapy: is downsizing the prostate with androgen deprivation necessary? , 2009, Brachytherapy.

[188]  G. Bauman,et al.  Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses , 2014, Radiation oncology.

[189]  A. Cramer,et al.  Real-time prostate motion assessment: image-guidance and the temporal dependence of intra-fraction motion , 2013, BMC medical physics.

[190]  Zuofeng Li,et al.  Outcomes in men with large prostates (≥ 60 cm3) treated with definitive proton therapy for prostate cancer , 2013, Acta oncologica.

[191]  L. Potters,et al.  Radical prostatectomy, external beam radiotherapy <72 Gy, external beam radiotherapy > or =72 Gy, permanent seed implantation, or combined seeds/external beam radiotherapy for stage T1-T2 prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[192]  E. B. Butler,et al.  Tolerance of Endorectal Balloon in 396 Patients Treated With Intensity-Modulated Radiation Therapy (IMRT) for Prostate Cancer , 2006, American journal of clinical oncology.

[193]  U. Kramer,et al.  Prospective evaluation of a hydrogel spacer for rectal separation in dose-escalated intensity-modulated radiotherapy for clinically localized prostate cancer , 2013, BMC Cancer.

[194]  Sunita Ghosh,et al.  Can images obtained with high field strength magnetic resonance imaging reduce contouring variability of the prostate? , 2011, International journal of radiation oncology, biology, physics.

[195]  A. Markoe,et al.  Long-term toxicity following 3D conformal radiation therapy for prostate cancer from the RTOG 9406 phase I/II dose escalation study. , 2010, International journal of radiation oncology, biology, physics.

[196]  T. Rosewall,et al.  Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. , 2007, International journal of radiation oncology, biology, physics.

[197]  C. Ménard,et al.  Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[198]  Issam El Naqa,et al.  Pelvic normal tissue contouring guidelines for radiation therapy: a Radiation Therapy Oncology Group consensus panel atlas. , 2012, International journal of radiation oncology, biology, physics.

[199]  C. Lawton,et al.  Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer , 2009 .

[200]  Jatinder Palta,et al.  Evaluation of kV Cone-Beam CT Performance for Prostate IGRT: A Comparison of Automatic Grey-Value Alignment to Implanted Fiducial-Marker Alignment , 2011, American journal of clinical oncology.

[201]  F F Yin,et al.  Tradeoffs of integrating real-time tracking into IGRT for prostate cancer treatment , 2009, Physics in medicine and biology.

[202]  G. Bauman,et al.  Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy. , 2011, International journal of radiation oncology, biology, physics.

[203]  J. Wong,et al.  Interfractional prostate shifts: review of 1870 computed tomography (CT) scans obtained during image-guided radiotherapy using CT-on-rails for the treatment of prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[204]  C. Catton,et al.  A randomized trial of supine vs. prone positioning in patients undergoing escalated dose conformal radiotherapy for prostate cancer. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[205]  E Bellon,et al.  The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[206]  Yair Lotan,et al.  Predictors of rectal tolerance observed in a dose-escalated phase 1-2 trial of stereotactic body radiation therapy for prostate cancer. , 2014, International journal of radiation oncology, biology, physics.

[207]  David Jaffray,et al.  Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery. , 2004, International journal of radiation oncology, biology, physics.

[208]  Wayne M Butler,et al.  Effect of metal hip prosthesis on the accuracy of electromagnetic localization tracking. , 2015, Practical radiation oncology.

[209]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[210]  Jay Shelton,et al.  Observations on prostate intrafraction motion and the effect of reduced treatment time using volumetric modulated arc therapy. , 2011, Practical radiation oncology.

[211]  Richard Pötter,et al.  Effects of geometric distortion in 0.2T MRI on radiotherapy treatment planning of prostate cancer. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[212]  P. Xia,et al.  The current status of image-guided external beam radiotherapy for prostate cancer , 2010, Current opinion in urology.

[213]  Matthew R Cooperberg,et al.  Time trends and local variation in primary treatment of localized prostate cancer. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[214]  Sasa Mutic,et al.  Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy. , 2012, Medical physics.

[215]  C K McGarry,et al.  Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer. , 2011, The British journal of radiology.

[216]  J. Vallée,et al.  Intensity modulated proton and photon therapy for early prostate cancer with or without transperineal injection of a polyethylen glycol spacer: a treatment planning comparison study. , 2012, International journal of radiation oncology, biology, physics.

[217]  D. Yan,et al.  Clinicopathologic analysis of extracapsular extension in prostate cancer: should the clinical target volume be expanded posterolaterally to account for microscopic extension? , 2004, International journal of radiation oncology, biology, physics.