This study presents a wireless power and data transmission system to overcome the problems in intracranial epilepsy monitoring associated with transcutaneous wires. Firstly, a wireless power transfer link based on inductive coupling is implemented and a power management unit for the implant is designed. 4-coil resonant inductive link scheme is exploited since it exhibits a high efficiency and optimal load flexibility. Power management unit consists of an active rectifier, a low drop-out voltage regulator which is biased internally with a supply independent current source; all implemented as integrated circuit. Wireless power link provides 10 mW under 1.8 V dc to the load, more specifically the electrodes and read-out electronics. Wireless data communication is realized using the same frequency, 8.4 MHz, as the power link. Load shift keying is performed for uplink (from implant to external) communication by switching an integrated modulator which, in fact, detunes the resonance. Modulated signal is recovered on the external device by means of an integrated self-referenced ASK demodulator. Data rate is adapted for a fast ripple ( < 500 Hz) detection system which requires 300 kbps communication. The measurements show that the system works at 36% power transfer efficiency without communication link and the efficiency drops to 33% with 300 kbps uplink data transfer. Finally, in-vitro tests that emulate the real operation scenario are performed thanks to the two-polymer packaging and almost the same power transfer efficiency is achieved under same operation conditions.
[1]
Chua-Chin Wang,et al.
Self-Sampled All-MOS ASK Demodulator for Lower ISM Band Applications
,
2010,
IEEE Transactions on Circuits and Systems II: Express Briefs.
[2]
M. Soljačić,et al.
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
,
2007,
Science.
[3]
Maysam Ghovanloo,et al.
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
,
2011,
IEEE Transactions on Biomedical Circuits and Systems.
[4]
Catherine Dehollain,et al.
Numerical analysis of temperature elevation in the head due to power dissipation in a cortical implant
,
2008,
2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[5]
Shahriar Mirabbasi,et al.
Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants
,
2011,
IEEE Transactions on Biomedical Circuits and Systems.
[6]
Catherine Dehollain,et al.
An efficient wireless power link for implanted biomedical devices via resonant inductive coupling
,
2012,
2012 IEEE Radio and Wireless Symposium.
[7]
Catherine Dehollain,et al.
A Wireless Power Link for Neural Recording Systems
,
2012
.
[8]
S D Lhatoo,et al.
The treatment of epilepsy in developing countries: where do we go from here?
,
2001,