Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX).

AIMS The aim of the study was to investigate the feasibility of performing segmental pulmonary vein (PV) isolation guided by the NavX (Endocardial Solutions, St Jude Medical, Inc., St Paul, MN, USA) system without the three-dimensional (3D) geometric reconstruction option and whether the use of NavX system will reduce the radiation exposure and procedure duration. METHODS AND RESULTS The study included 64 patients with symptomatic paroxysmal or permanent atrial fibrillation, in whom PV isolation was performed using fluoroscopic guidance (n=32) or the NavX system (n=32). Pulmonary vein mapping with a circular mapping catheter allowed the identification and localization of myocardial connections between the PV and the left atrium. PV isolation was performed by radiofrequency ablation of these connections at the atrial aspect of the PV ostium. Primary success rate for isolated PVs did not differ significantly in patients ablated under fluoroscopic guidance vs. those ablated under guidance of NavX system [100/107 PVs (93.5%) vs. 120/124 PV (96.8%; P=n.s.)]. Compared with fluoroscopy guided procedures, NavX-guided procedures showed a significant reduction in the fluoroscopy time (75.8+/-24.5 vs. 38.9+/-19.3 min, P<0.05), total X-ray exposure (93.2+/-51.6 vs. 56.6+/-37.9 Gy cm(2), P=0.03), and total procedural time (237.7+/-65.4 vs. 188.6+/-62.7 min, P=0.01). The mean follow-up was 9.5+/-3.0 months. One patient in each group was lost to follow-up. Seven-day Holter monitoring showed that 23 of 31 patients (74.2%) in the NavX-guided group and 21 of 31 patients (67.7%) in the fluoroscopy-guided group were in sinus rhythm (P=0.57). CONCLUSION The 3D visualization of the catheters by NavX system allows a rapid and precise visualization of the mapping and ablation catheters at the PV ostia and markedly reduces fluoroscopy time, total X-ray exposure, and procedural duration during PV isolation compared with ablation performed under fluoroscopy guidance.

[1]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[2]  Hakan Oral,et al.  Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation , 2002, Circulation.

[3]  F. Sacher,et al.  Left Atrial Linear Ablation to Modify the Substrate of Atrial Fibrillation Using a New Nonfluoroscopic Imaging System , 2005, Pacing and clinical electrophysiology : PACE.

[4]  Michel Haïssaguerre,et al.  Pulmonary Vein Disconnection Using the LocaLisa Three‐Dimensional Nonfluoroscopic Catheter Imaging System , 2003, Journal of cardiovascular electrophysiology.

[5]  Prashanthan Sanders,et al.  Changes in Atrial Fibrillation Cycle Length and Inducibility During Catheter Ablation and Their Relation to Outcome , 2004, Circulation.

[6]  J Clémenty,et al.  Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins , 2000, Circulation.

[7]  Prashanthan Sanders,et al.  Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system. , 2005, European heart journal.

[8]  Anil Goel,et al.  Catheter Location, Tracking, Cardiac Chamber Geometry Creation, and Ablation Using Cutaneous Patches , 2005, Journal of Interventional Cardiac Electrophysiology.

[9]  Claus Schmitt,et al.  Freedom From Atrial Tachyarrhythmias After Catheter Ablation of Atrial Fibrillation: A Randomized Comparison Between 2 Current Ablation Strategies , 2005, Circulation.

[10]  J. Yang,et al.  Tongue-lip adhesion in the management of Pierre Robin sequence with airway obstruction: technique and outcome. , 2005, Chang Gung medical journal.

[11]  P. Tchou,et al.  Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies. , 2002, Journal of the American College of Cardiology.

[12]  Ottavio Alfieri,et al.  Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation Efficacy of an Anatomic Approach in a Large Cohort of Patients With Atrial Fibrillation , 2002 .

[13]  C. Tai,et al.  Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. , 1999, Circulation.

[14]  J Clémenty,et al.  A focal source of atrial fibrillation treated by discrete radiofrequency ablation. , 1997, Circulation.

[15]  R N Hauer,et al.  LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes. , 1999, Circulation.

[16]  C. Tondo,et al.  A New Nonfluoroscopic Navigation System to Guide Pulmonary Vein Isolation , 2005, Pacing and clinical electrophysiology : PACE.

[17]  Michael A. E. Schneider,et al.  LocaLisa Catheter Navigation Reduces Fluoroscopy Time and Dosage in Ablation of Atrial Flutter: , 2003, Journal of cardiovascular electrophysiology.

[18]  K. Ellenbogen,et al.  Use of a Non-Fluoroscopic Catheter Navigation System for Pulmonary Vein Isolation , 2004, Journal of Interventional Cardiac Electrophysiology.

[19]  Michael A. E. Schneider,et al.  Acute and Long‐Term Results of Slow Pathway Ablation in Patients with Atrioventricular Nodal Reentrant Tachycardia—An Analysis of the Predictive Factors for Arrhythmia Recurrence , 2005, Pacing and clinical electrophysiology : PACE.

[20]  Michael A. E. Schneider,et al.  Circumferential mapping and electric isolation of pulmonary veins in patients with atrial fibrillation. , 2003, The American journal of cardiology.