Calibration of a Wearable Glucose Sensor

Calibration of glucose sensors proved difficult for electrodes with immobilized glucose-oxidase. The correlation between the sensitivity of the electrodes in vitro and in vivo appeared to be poor. We developed a new type of glucose sensor, based on a microdialysis system, in which an oxygen electrode is used as detector outside the body and the enzyme glucose-oxidase dissolved in water is used as a dynamic selector. The enzyme solution is pumped through a hollow fiber placed subcutaneously, before the fluid passes the detector. The glucose sensor was tested in the subcutaneous abdominal tissue of 12 healthy volunteers and 12 type I diabetic patients. Blood glucose was clamped at two levels to permit a two-point calibration of the sensor in vivo. These values correlated well with the in vitro calibration factors (r=0.949). In subcutaneous tissue the sensor measures 43 ± 9% of the blood glucose value, using the in vitro calibration factor. No differences were detected between healthy volunteers and diabetic patients.

[1]  H. Doorenbos,et al.  Development of a Wearable Glucose Sensor; Studies in Healthy Volunteers and in Diabetic Patients , 1991, The International journal of artificial organs.

[2]  D. Matthews,et al.  An Amperometric Needle‐type Glucose Sensor Tested in Rats and Man , 1988, Diabetic medicine : a journal of the British Diabetic Association.

[3]  D. Gough,et al.  Short-term in vivo operation of a glucose sensor. , 1986, ASAIO transactions.

[4]  Y. Yamasaki,et al.  Telemetry Glucose Monitoring Device With Needle-Type Glucose Sensor: A Useful Tool for Blood Glucose Monitoring in Diabetic Individuals , 1986, Diabetes Care.

[5]  D. Gough,et al.  Two-dimensional enzyme electrode sensor for glucose. , 1985, Analytical chemistry.

[6]  G. Guilbault Enzymatic Glucose Electrodes , 1982, Diabetes Care.

[7]  C. Lerk,et al.  Development of a potentially wearable glucose sensor for patients with diabetes mellitus: design and in-vitro evaluation. , 1990, Biosensors & bioelectronics.

[8]  G Reach,et al.  Strategies for calibrating a subcutaneous glucose sensor. , 1989, Biomedica biochimica acta.

[9]  K. Rebrin,et al.  In situ calibration of implanted electrochemical glucose sensors. , 1989, Biomedica biochimica acta.

[10]  K. Cammann Implantable electrochemical glucose sensors--state of the art. , 1988, Hormone and metabolic research. Supplement series.

[11]  Gérard Reach,et al.  In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics , 1988 .

[12]  L. Gorton,et al.  An amperometric glucose sensor made by modification of a graphite electrode surface with immobilized glucose oxidase and adsorbed mediator. , 1985, Biosensors.

[13]  P Abel,et al.  Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. , 1984, Biomedica biochimica acta.

[14]  E. Wilkins,et al.  Implantable glucose sensor. , 1983, Journal of biomedical engineering.

[15]  A. Felice,et al.  In vitro synthesis of hemoglobin and hemoglobin chains in the BFUe-derived colonies form person with alpha- or beta-thalassemia. , 1981, American journal of hematology.