Development of a finger biomechanical model and its considerations.

The development of a biomechanical model for a human finger is faced with many challenges, such as extensor mechanism complexity, statistical indeterminacy and suitability of computational processes. Motivation for this work was to develop a computer model that is able to predict the internal loading patterns of tendons and joint surfaces experienced by the human finger, while mitigating these challenges. Proposed methodology was based on a non-linear optimising mathematical technique with a criterion of boundary conditions and equality equations, maximised against unknown parameters to reduce statistical indeterminacy. Initial validation was performed via the simulation of one dynamic and two static postures case studies. Past models and experiments were used, based on published literature, to verify the proposed model's methodology and results. The feasibility of the proposed methodology was deemed satisfactory as the simulated results were concordant with in-vivo results for the extrinsic flexors.

[1]  K. An,et al.  Gliding resistance after repair of partially lacerated human flexor digitorum profundus tendon in vitro. , 2001, Clinical biomechanics.

[2]  J T Dennerlein,et al.  A low profile human tendon force transducer: the influence of tendon thickness on calibration. , 1997, Journal of biomechanics.

[3]  W P Cooney,et al.  Flexor tendon forces: in vivo measurements. , 1992, The Journal of hand surgery.

[4]  Edmund Y. S. Chao,et al.  Biomechanics of the hand : a basic research study , 1989 .

[5]  E. Zancolli Structural and dynamic bases of hand surgery , 1979 .

[6]  K N An,et al.  Determination of muscle and joint forces: a new technique to solve the indeterminate problem. , 1984, Journal of biomechanical engineering.

[7]  D. Mehler,et al.  Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula , 2004, Archives of Orthopaedic and Trauma Surgery.

[8]  Jack M. Winters,et al.  Multiple Muscle Systems: Biomechanics and Movement Organization , 2011 .

[9]  Robert G. Radwin,et al.  Grip Force Vectors for Varying Handle Diameters and Hand Sizes , 2004, Hum. Factors.

[10]  Kai-Nan An,et al.  Flexor digitorum profundus tendon tension during finger manipulation. , 2005, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[11]  Joseph M. Mansour,et al.  A dynamic model of the hand with application in functional neuromuscular stimulation , 2007, Annals of Biomedical Engineering.

[12]  K. Kilgore,et al.  The function of the finger intrinsic muscles in response to electrical stimulation. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[13]  David Rempel,et al.  Finger flexor motor control patterns during active flexion: an in vivo tendon force study. , 2007, Human movement science.

[14]  D. Thompson,et al.  A clinical study of forces generated by the intrinsic muscles of the index finger and the extrinsic flexor and extensor muscles of the hand. , 1978, The Journal of hand surgery.

[15]  J L Sancho-Bru,et al.  A 3-D dynamic model of human finger for studying free movements. , 2001, Journal of biomechanics.

[16]  V M Zatsiorsky,et al.  The effect of finger extensor mechanism on the flexor force during isometric tasks. , 2001, Journal of biomechanics.

[17]  S Pagowski,et al.  Biomechanics of metacarpophalangeal joint. , 1977, Journal of biomechanics.

[18]  R. Crowninshield,et al.  A physiologically based criterion of muscle force prediction in locomotion. , 1981, Journal of biomechanics.

[19]  Landsmeer Jm Studies in the anatomy of articulation. I. The equilibrium of the "intercalated" bone. , 1961 .

[20]  K N An,et al.  Normative model of human hand for biomechanical analysis. , 1979, Journal of biomechanics.

[21]  E. M. Smith,et al.  ROLE OF THE FINGER FLEXORS IN RHEUMATOID DEFORMITIES OF THE METACARPOPHALANGEAL JOINTS. , 1964, Arthritis and rheumatism.

[22]  J Mizrahi,et al.  A biomechanical model of index finger dynamics. , 1995, Medical engineering & physics.

[23]  J T Dennerlein,et al.  Tensions of the flexor digitorum superficialis are higher than a current model predicts. , 1998, Journal of biomechanics.

[24]  C. Long Intrinsic-extrinsic muscle control of the fingers. Electromyographic studies. , 1968, The Journal of bone and joint surgery. American volume.

[25]  N K Fowler,et al.  Interphalangeal joint and tendon forces: normal model and biomechanical consequences of surgical reconstruction. , 2000, Journal of biomechanics.

[26]  R. Beasley Beasley's Surgery of the Hand , 2003 .

[27]  K. Kursa,et al.  In vivo forces generated by finger flexor muscles do not depend on the rate of fingertip loading during an isometric task. , 2005, Journal of biomechanics.

[28]  E Y Chao,et al.  Three-dimensional force analysis of finger joints in selected isometric hand functions. , 1976, Journal of biomechanics.

[29]  K. J. Cole,et al.  Coordination of index finger movements. , 1994, Journal of biomechanics.

[30]  S. Bunnell SURGERY OF THE HAND , 1940, The Ulster Medical Journal.

[31]  Rodrigo Kaz,et al.  Finger joint motion generated by individual extrinsic muscles: A cadaveric study , 2008, Journal of orthopaedic surgery and research.

[32]  F. Zajac,et al.  Large index-fingertip forces are produced by subject-independent patterns of muscle excitation. , 1998, Journal of biomechanics.

[33]  Chandana Paul,et al.  The Tendon Network of the Fingers Performs Anatomical Computation at a Macroscopic Scale , 2007, IEEE Transactions on Biomedical Engineering.

[34]  J. Landsmeer,et al.  Electromyographic kinesiology of the hand: muscles driving the index finger. , 1969, Archives of Physical Medicine and Rehabilitation.

[35]  A A Amis,et al.  Finger joint force predictions related to design of joint replacements. , 1982, Journal of biomedical engineering.

[36]  T J Armstrong,et al.  A kinematic model of the human hand to evaluate its prehensile capabilities. , 1992, Journal of biomechanics.

[37]  F. Netter Atlas of Human Anatomy , 1967 .

[38]  John F. Gardner Simulations of Machines Using MATLAB and Simulink , 2000 .

[39]  K. An,et al.  DETERMINATION OF INTERNAL FORCES IN HUMAN HAND , 1978 .

[40]  R Bartlett,et al.  Inverse optimization: functional and physiological considerations related to the force-sharing problem. , 1997, Critical reviews in biomedical engineering.

[41]  Antonio Pedotti,et al.  Optimization of muscle-force sequencing in human locomotion , 1978 .

[42]  J. P. Paul,et al.  A biomechanical analysis of the metacarpo-phalangeal joint , 1977 .

[43]  R. L. Linscheid,et al.  Forces in the normal and abnormal hand , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[44]  P. Brand,et al.  Tendon and pulleys at the metacarpophalangeal joint of a finger. , 1975, The Journal of bone and joint surgery. American volume.

[45]  Franck Quaine,et al.  Using EMG data to constrain optimization procedure improves finger tendon tension estimations during static fingertip force production. , 2007, Journal of biomechanics.

[46]  D B Chaffin,et al.  An investigation of the relationship between displacements of the finger and wrist joints and the extrinsic finger flexor tendons. , 1978, Journal of biomechanics.

[47]  I. Kapandji The Physiology of the Joints , 1988 .

[48]  B M Hillberry,et al.  Finger joint force minimization in pianists using optimization techniques. , 1993, Journal of biomechanics.