CARDIOVASCULAR TISSUE ENGINEERING: A NEW LAMINAR FLOW CHAMBER FOR IN VITRO IMPROVEMENT OF MECHANICAL TISSUE PROPERTIES

A new in vitro flow system was developed to investigate the impact of laminar flow on extracellular matrix formation and tissue development. The dynamic in vitro system was designed to provide a cross flow arrangement of main flow induced by a dialysis roller pump (500 ml/min), and nutrition flow by a perfusion pump (3 ml/hr). Poly-L-lysine precoated polyglycolic acid (PGA) scaffolds (3.14 cm2) were seeded with myofibroblasts of human aortic origin (3.0 × 106 cells/mesh) and incubated for 14 days under static conditions. The tissue was exposed to shear stress over a time period of 14 days (n = 4). The control group was seeded under static conditions (n = 4). To obtain a CO2 independent medium, 25 mM HEPES and 1 mM bicarbonate buffer was supplemented to modified MEM without bicarbonate. Gas samples were collected from the medium, and hydroxyproline assay was performed as a marker of collagen production. The newly developed flow system maintained stable cell culture conditions, with the hydroxyproline concentration significantly higher in group F (p < 0.05). These preliminary experiences with a new in vitro tissue culture system demonstrate the feasibility of using flow induced mechanical stress to enhance extracellular matrix formation.

[1]  C K Breuer,et al.  Tissue-engineered heart valves. Autologous valve leaflet replacement study in a lamb model. , 1996, Circulation.

[2]  F J Schoen,et al.  Cardiac tissue engineering: cell seeding, cultivation parameters, and tissue construct characterization. , 1999, Biotechnology and bioengineering.

[3]  B. Obradovic,et al.  Bioreactor cultivation conditions modulate the composition and mechanical properties of tissue‐engineered cartilage , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  Ajit P. Yoganathan,et al.  Estimation of the Shear Stress on the Surface of an Aortic Valve Leaflet , 1999, Annals of Biomedical Engineering.

[5]  C. Enwemeka,et al.  A simplified method for the analysis of hydroxyproline in biological tissues. , 1996, Clinical biochemistry.

[6]  R. Sodian,et al.  Tissue engineering of small caliber vascular grafts. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  T. Matsuda,et al.  Mechanical stress induced cellular orientation and phenotypic modulation of 3-D cultured smooth muscle cells. , 1993, ASAIO journal.

[8]  J E Mayer,et al.  Evaluation of biodegradable, three-dimensional matrices for tissue engineering of heart valves. , 2000, ASAIO journal.

[9]  C. Peskin,et al.  Mechanical equilibrium determines the fractal fiber architecture of aortic heart valve leaflets. , 1994, The American journal of physiology.

[10]  I Vesely,et al.  The role of elastin in aortic valve mechanics. , 1997, Journal of biomechanics.

[11]  S. Hoerstrup,et al.  Tissue engineering: a new approach in cardiovascular surgery: Seeding of human fibroblasts followed by human endothelial cells on resorbable mesh. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  F J Schoen,et al.  Tissue engineering of heart valves: in vitro experiences. , 2000, The Annals of thoracic surgery.