Models and regulatory considerations for transient temperature rise during diagnostic ultrasound pulses.

A new diagnostic ultrasound (US) technique, sometimes called radiation force imaging, produces and detects motion in solid tissue or acoustic streaming in fluids via a high-intensity beam. Current models for estimating temperature rise during US exposure calculate the steady-state rise, using time-averaged acoustic output, as the worst case for safety consideration. Although valid for very short pulses, this analysis might not correspond to a worst-case scenario for the longer pulses or pulse bursts, up to hundreds of ms, used by this newer method. Models are presented to calculate the transient temperature rise from these pulse bursts for both the bone at focus and soft tissue situation. It is shown, based on accepted time-temperature dose criteria, that, for the bone at focus case and pulse lengths and intensities utilized by these methods, temperature may increase to levels that raise safety concerns. Also, regulatory aspects of this modality are analyzed in terms of the current FDA acoustic output limits for diagnostic US devices.

[1]  J. C. Jaeger,et al.  Conduction of Heat in Solids , 1952 .

[2]  M. Ziskin,et al.  International recommendations and guidelines for the safe use of diagnostic ultrasound in medicine. , 2000, Ultrasound in medicine & biology.

[3]  J. G. Abbott,et al.  Rationale and derivation of MI and TI--a review. , 1999, Ultrasound in medicine & biology.

[4]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[5]  G E Trahey,et al.  The use of acoustic streaming in breast lesion diagnosis: a clinical study. , 1999, Ultrasound in medicine & biology.

[6]  Wesley L. Nyborg,et al.  Physical Mechanisms for Biological Effects of Sound , 1965 .

[7]  E. Carstensen,et al.  Nonlinear propagation and the output indices. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[8]  G. Trahey,et al.  On the feasibility of remote palpation using acoustic radiation force. , 2001, The Journal of the Acoustical Society of America.

[9]  W F Walker,et al.  Internal deformation of a uniform elastic solid by acoustic radiation force. , 1999, The Journal of the Acoustical Society of America.

[10]  M.G. Curley,et al.  Soft tissue temperature rise caused by scanned, diagnostic ultrasound , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Morton W. Miller,et al.  Biological consequences of hyperthermia. , 1989, Ultrasound in medicine & biology.

[12]  F. Duck Acoustic saturation and output regulation. , 1999, Ultrasound in medicine & biology.

[13]  F. Duck,et al.  The output of pulse-echo ultrasound equipment: a survey of powers, pressures and intensities. , 1985, The British journal of radiology.

[14]  W. O’Brien,et al.  The monopole-source solution for estimating tissue temperature increases for focused ultrasound fields , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  K. Thomenius Impact of nonlinear propagation on temperature distributions caused by diagnostic ultrasound , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[16]  W. Nyborg Solutions of the bio-heat transfer equation. , 1988, Physics in medicine and biology.

[17]  D. R. Bacon,et al.  Experimental validation of predicted temperature rises in tissue-mimicking materials. , 1993, Physics in medicine and biology.

[18]  F. Duck,et al.  Trends in diagnostic ultrasound exposure. , 1991, Physics in medicine and biology.

[19]  P. Edmonds Physical mechanisms for biological effects of ultrasound: By W. L. Nyborg. DHEW Publication (FDA) 78-8062,59 pp., available without charge from BRH Technical Information Staff (HFX-25), 5600 Fishers Lane, Rockville, MD 20857 (Limited distribution) , 1978 .

[20]  R. Phillips,et al.  Output levels and bioeffects indices from diagnostic ultrasound exposure data reported to the FDA , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  E. Madsen,et al.  Acoustic measurements in a tissue mimicking liquid. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[22]  L A Crum,et al.  Color Doppler detection of acoustic streaming in a hematoma model. , 2001, Ultrasound in medicine & biology.