22.4 A 172µW compressive sampling photoplethysmographic readout with embedded direct heart-rate and variability extraction from compressively sampled data

Heart rate (HR) and its variability (HRV) provide critical information about an individual's cardiovascular and mental health state. In either application, long-term observation is crucial to arrive at conclusive decisions and provide useful diagnostic feedback [1]. Photoplethysmographic (PPG) estimation of HR and HRV has emerged as an attractive alternative to ECG, as it provides electrode-free operation increasing patient comfort. However, PPG monitoring systems robust to low ambient light conditions and low perfusion conditions require a LED as a light source, which strongly dominates the power consumption of the complete system. Compressive sampling (CS) based PPG readouts promise to mitigate this LED power consumption [2], yet require large computational power to recover the signal, hindering real-time embedded processing on energy-scarce wearable devices. This paper presents a fully integrated, low-power PPG readout ASIC, completely integrating a single-channel readout front-end (AFE) and a 12b SAR ADC and a digital back-end (DBE) for embedded energy-efficient real-time information extraction, that advances the state-of-the-art on the following fronts: 1) By smartly duty-cycling all system components synchronously on a sparse non-uniform CS sampling pulse stream, the LED driver power is reduced up to 30x, without significant loss of information. 2) Moreover, the necessity of wireless off-loading, or for computationally intensive embedded signal reconstruction, is circumvented by enabling the direct extraction of HR and HRV information from the compressed data in real-time on the ASIC, while consuming only 172μW for the complete system.

[1]  Refet Firat Yazicioglu,et al.  Computationally-efficient compressive sampling for low-power pulseoximeter system , 2014, 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings.

[2]  Rahul Sarpeshkar,et al.  An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[3]  Mohammad Alhawari,et al.  A 0.5V <4µW CMOS photoplethysmographic heart-rate sensor IC based on a non-uniform quantizer , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[4]  Yuan-Ting Zhang,et al.  A Low-Power CMOS Front-End for Photoplethysmographic Signal Acquisition With Robust DC Photocurrent Rejection , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Charles Sodini,et al.  A Low-Power, Dual-Wavelength Photoplethysmogram (PPG) SoC With Static and Time-Varying Interferer Removal , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[6]  Hao Liu,et al.  Towards mental stress detection using wearable physiological sensors , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.