Effect of applied force and blade speed on histopathology of bone during resection by sagittal saw.

A sagittal saw is commonly used for resection of bone during joint replacement surgery. During sawing, heat is generated that can lead to an increase in temperature at the resected surface. The aim of this study was to determine the effect of applied thrust force and blade speed on generating heat. The effect of these factors and their interactions on cutting temperature and bone health were investigated with a full factorial Design of Experiments approach for two levels of thrust force, 15 N and 30 N, and for two levels of blade oscillation rate, 12,000 and 18,000 cycles per minute (cpm). In addition, a preliminary study was conducted to eliminate blade wear as a confounding factor. A custom sawing fixture was used to crosscut samples of fresh bovine cortical bone while temperature in the bone was measured by thermocouple (n=40), followed by measurements of the depth of thermal necrosis by histopathological analysis (n=200). An analysis of variance was used to determine the significance of the factor effects on necrotic depth as evidenced by empty lacunae. Both thrust force and blade speed demonstrated a statistically significant effect on the depth of osteonecrosis (p<0.05), while the interaction of thrust force with blade speed was not significant (p=0.22). The minimum necrotic depth observed was 0.50mm, corresponding to a higher level of force and blade speed (30 N, 18,000 cpm). Under these conditions, a maximum temperature of 93°C was measured at 0.3mm from the kerf. With a decrease in both thrust force and blade speed (15N, 12,000 cpm), the temperature in the bone increased to 109°C, corresponding to a nearly 50% increase in depth of the necrotic zone to 0.74 mm. A predictive equation for necrotic depth in terms of thrust force and blade speed was determined through regression analysis and validated by experiment. The histology results imply that an increase in applied thrust force is more effective in reducing the depth of thermal damage to surrounding bone than an increase in blade speed.

[1]  G. Augustin,et al.  Cortical bone drilling and thermal osteonecrosis. , 2012, Clinical biomechanics.

[2]  S. K. Chatterji,et al.  Age-related changes in the density and tensile strength of human femoral cortical bone , 1979, Calcified Tissue International.

[3]  W R Krause,et al.  Temperature elevations in orthopaedic cutting operations. , 1982, Journal of biomechanics.

[4]  R. Edlich,et al.  Influence of irrigation solutions on oscillating bone saw blade performance. , 1998, Journal of biomedical materials research.

[5]  Thomas P. James,et al.  Rounded cutting edge model for the prediction of bone sawing forces. , 2012, Journal of biomechanical engineering.

[6]  Jan Lundskog,et al.  Oxygen consumption by granulation tissue in bipedicle tube flaps. , 1975 .

[7]  T Albrektsson,et al.  The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber. , 1984, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[8]  Jiju Antony,et al.  Design of experiments for engineers and scientists , 2003 .

[9]  B. Aksakal,et al.  Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study. , 2011, Medical engineering & physics.

[10]  Toma Udiljak,et al.  Thermal osteonecrosis and bone drilling parameters revisited , 2007, Archives of Orthopaedic and Trauma Surgery.

[11]  S. Toksvig-Larsen,et al.  Temperature influence in different orthopaedic saw blades. , 1992, The Journal of arthroplasty.

[12]  P. Stoll,et al.  Increase of temperature during osteotomy. In vitro and in vivo investigations. , 1991, International journal of oral and maxillofacial surgery.

[13]  B. Noble,et al.  Bone microdamage and cell apoptosis. , 2003, European cells & materials.

[14]  T Albrektsson,et al.  Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. , 1983, The Journal of prosthetic dentistry.

[15]  L Ryd,et al.  Temperature elevation during knee arthroplasty. , 1989, Acta orthopaedica Scandinavica.

[16]  G. Ciapetti,et al.  Cellular events in the mechanisms of prosthesis loosening. , 1991, Clinical materials.

[17]  D. F. James,et al.  Measurement of thermal conductivity of bovine cortical bone. , 2000, Medical engineering & physics.

[18]  F. Kreith,et al.  Principles of heat transfer , 1962 .

[19]  L Ryd,et al.  On the problem of heat generation in bone cutting. Studies on the effects on liquid cooling. , 1991, The Journal of bone and joint surgery. British volume.