Building energy performance analysis of ultra-high-performance fiber-reinforced concrete (UHP-FRC) façade systems

Abstract Majority of building energy consumption is used to heat and cool enclosed spaces. An innovative ultra-high-performance fiber-reinforced concrete (UHP-FRC) facade system could potentially reduce this energy consumption by utilizing UHP-FRC's high structural strength and ductility hence more space for insulation. The energy performance assessment of innovative facade systems such as UHP-FRC panels could be misleading if the effect of building types and climate contexts on building energy consumption is not considered. Moreover, thermal bridging and hygrothermal analyses of UHP-FRC panels are needed to investigate the heat and moisture transfer within the panels in details. The objective of this paper is to investigate the combined effect of different building types and climate conditions on these panels’ energy performance and analyze the heat and moisture behavior within the panels in a detailed assembly scale. Numerical heat and moisture transfer simulations were conducted to evaluate the amount of risk of thermal bridging and risk of mold growth within innovative UHP-FRC facade systems. A probabilistic simulation-based building energy performance analysis was conducted to investigate the combined effect of different building types and climate conditions on the energy performance of UHP-FRC panel systems. The analysis was conducted for fourteen U.S. Department of Energy prototype buildings in fifteen climate zones (210 scenarios). The results of thermal bridging analysis showed that the UHP-FRC panel assembly provides unique thermal properties with higher thermal resistance compared with the conventional panel assembly. The UHP-FRC panel assembly minimizes the thermal bridging by eliminating the structural rebars. However, the energy savings of using UHP-FRC panels depend on the building type and climate condition. On average, energy savings are higher in colder climates (e.g., Fairbanks) than those in temperate climates (e.g., San Francisco). Also, buildings dominated by internal loads seem to benefit the least from UHP-FRC. The hygrothermal analysis also showed that the UHP-FRC panel assembly's performance is superior than the conventional panel in terms of moisture transfer and the risk of mold growth.

[1]  Shih Ho Chao,et al.  Investigation of Eliminating Prestress in Bridge Girders with the Use of Non-Prestressed Ultra-High-Performance Fiber-Reinforced Concrete Girders , 2018 .

[2]  Moncef Krarti,et al.  Energy performance analysis of variable thermal resistance envelopes in residential buildings , 2015 .

[3]  Shih Ho Chao,et al.  Developing Ultra-High-Performance Fiber-Reinforced Concrete for Large-Scale Structural Applications , 2016 .

[4]  J. New,et al.  Evaluation of weather datasets for building energy simulation , 2012 .

[5]  Jlm Jan Hensen,et al.  Uncertainty analysis in building performance simulation for design support , 2011 .

[6]  J. Alexandre Bogas,et al.  Contribution of structural lightweight aggregate concrete to the reduction of thermal bridging effect in buildings , 2016 .

[7]  Kevin J. Lomas,et al.  Sensitivity analysis techniques for building thermal simulation programs , 1992 .

[8]  Bing Liu,et al.  U.S. Department of Energy Commercial Reference Building Models of the National Building Stock , 2011 .

[9]  Norbert Lechner,et al.  Heating, Cooling, Lighting: Sustainable Design Methods for Architects , 2008 .

[10]  Robert F. Boehm,et al.  Passive building energy savings: A review of building envelope components , 2011 .

[11]  Christiaan J. J. Paredis,et al.  TOWARDS BETTER PREDICTION OF BUILDING PERFORMANCE: A WORKBENCH TO ANALYZE UNCERTAINTY IN BUILDING SIMULATION , 2013 .

[12]  Xiufeng Pang,et al.  Uncertainties in Energy Consumption Introduced by Building Operations and Weather for a Medium-Size Office Building , 2012 .

[13]  Robert Černý,et al.  Hygrothermal performance study of an innovative interior thermal insulation system , 2009 .

[14]  Paul Raftery,et al.  A review of methods to match building energy simulation models to measured data , 2014 .

[15]  Bryan Eisenhower,et al.  CALIBRATION OF ENVELOPE PARAMETERS USING CONTROL-BASED HEAT BALANCE IDENTIFICATION AND UNCERTAINTY ANALYSIS , 2013 .

[16]  Drury B. Crawley,et al.  EnergyPlus: Energy simulation program , 2000 .

[17]  Liu Yang,et al.  Sensitivity analysis and energy conservation measures implications , 2008 .

[18]  Kotek Petr,et al.  TECHNIQUE OF UNCERTAINTY AND SENSITIVITY ANALYSIS FOR SUSTAINABLE BUILDING ENERGY SYSTEMS PERFORMANCE CALCULATIONS , 2007 .

[19]  Zheng O'Neill,et al.  Uncertainty and sensitivity decomposition of building energy models , 2012 .

[20]  Matteo Iommi,et al.  The mediterranean smart adaptive wall. An experimental design of a smart and adaptive facade module for the mediterranean climate , 2018 .

[21]  Caroline Hachem,et al.  Patterns of façade system design for enhanced energy performance of multistory buildings , 2016 .

[22]  O. Guerra-Santin,et al.  Occupants' behaviour: determinants and effects on residential heating consumption , 2010 .

[23]  Godfried Augenbroe,et al.  Uncertainty quantification of microclimate variables in building energy simulation , 2011 .

[24]  Devin K. Harris,et al.  Characterization of Strength and Durability of Ultra-High-Performance Concrete under Variable Curing Conditions , 2011 .

[25]  Godfried Augenbroe,et al.  Analysis of uncertainty in building design evaluations and its implications , 2002 .

[26]  Christina J. Hopfe,et al.  Uncertainty and sensitivity analysis for detailed design support , 2007 .

[27]  Ruut Hannele Peuhkuri,et al.  Effect of façade impregnation on feasibility of capillary active thermal internal insulation for a historic dormitory – A hygrothermal simulation study , 2016 .

[28]  M. F. Jentsch,et al.  Sensitivity And Uncertainty Analysis of Models for Determining Energy Consumption in the Residential Sector , 2015, Building Simulation Conference Proceedings.

[29]  Mark Luther,et al.  Energy efficient envelope design for high-rise apartments , 2005 .

[30]  David J. Sailor,et al.  A green roof model for building energy simulation programs , 2008 .

[31]  Ossama A. Abdou,et al.  Thermal performance evaluation of a prefabricated fiber-reinforced plastic building envelope system , 1996 .

[32]  M. D. McKay,et al.  A comparison of three methods for selecting values of input variables in the analysis of output from a computer code , 2000 .

[33]  K. F. Fong,et al.  Investigation on energy performance of double skin façade in Hong Kong , 2009 .