Signal-to-noise ratio analysis of X-ray grating interferometry with the reverse projection extraction method

In the past decade, grating-based X-ray phase contrast imaging has attracted increasing attention. Particular efforts have been devoted to develop new information extraction method for its forthcoming practical applications. Here we discuss the noise properties of a new acquisition protocol, dubbed the "reverse projection" (RP) method, using the error propagation formula. We present a quantitative analysis of the signal-to-noise ratio of X-ray grating interferometry with this new method. As the major sources of noise, the contributions from photon statistics and mechanical errors are discussed in detail. The results show how the system parameters impact on the extracted absorption and refraction images and how they can be used to optimize the system design for foreseen practical applications, such as biomedical imaging and materials science. (C) 2014 Elsevier B.V. All rights reserved.

[1]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[2]  Ziyu Wu,et al.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging , 2010, Proceedings of the National Academy of Sciences.

[3]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[4]  F. Pfeiffer,et al.  Advanced phase-contrast imaging using a grating interferometer. , 2009, Journal of synchrotron radiation.

[5]  Franz Pfeiffer,et al.  X-ray phase radiography and tomography of soft tissue using grating interferometry. , 2008, European journal of radiology.

[6]  R. Kaufmann,et al.  Noise analysis of grating-based x-ray differential phase contrast imaging. , 2010, The Review of scientific instruments.

[7]  C. David,et al.  Differential x-ray phase contrast imaging using a shearing interferometer , 2002 .

[8]  F. Pfeiffer,et al.  Trimodal low-dose X-ray tomography , 2012, Proceedings of the National Academy of Sciences.

[9]  Ke Li,et al.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography. , 2010, Medical physics.

[10]  Franz Pfeiffer,et al.  Interlaced phase stepping in phase-contrast x-ray tomography , 2011 .

[11]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[12]  Thilo Michel,et al.  Measurements and simulations analysing the noise behaviour of grating-based X-ray phase-contrast imaging , 2011 .

[13]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[14]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[15]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[16]  Yijin Liu,et al.  Analysis of partial coherence in grating-based phase-contrast X-ray imaging , 2010 .

[17]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[18]  K. A. Semendyayev,et al.  Handbook of mathematics , 1985 .

[19]  Franz Pfeiffer,et al.  Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source. , 2009, Optics express.

[20]  Dan Stutman,et al.  Talbot phase-contrast x-ray imaging for the small joints of the hand , 2011, Physics in medicine and biology.

[21]  Ziyu Wu,et al.  Grating-based X-ray phase contrast imaging using polychromatic laboratory sources , 2011 .